{"product_id":"mv-105-power-cable-w-ground-5kv-8kv-epr-pvc-insulation-copper-tape-shield-133-100-insulation-level","title":"MV-105 Power Cable w\/ Ground, 5kV\/8kV, EPR\/PVC Insulation, Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e[short]\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eMV-105 Power Cable w\/ Ground, 5kV\/8kV, EPR\/PVC Insulation, Copper Tape Shield, 133%\/100% Insulation Level\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e [\/short]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMV105 THREE CONDUCTOR 5KV POWER CABLE\u003c\/p\u003e\n\u003cp\u003eThis cable is meant for heavy duty applications in corrosive environments given that it has three conductors. It has a voltage rating of 5000 volts and 8000 volts. The operating temperature of this cable is slightly higher compared to the previous cables. It normally operates at 105 degrees Celsius but in case of an emergency overload it can withstand temperatures up to 140 degrees Celsius and if a short circuit occurs it can withstand a temperature of 250 degrees Celsius. It’s mainly used in chemical plants, industrial plants, refineries and commercial buildings.\u003c\/p\u003e\n\u003cp\u003eThis cable has three \u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/copper-building-wire\"\u003ecopper conductors\u003c\/a\u003e and a semi-conducting shield on the conductors. Among the three conductors is a ground conductor which also withholds current under normal operation of the cable. The conductors on this cable are also stranded which enhances flexibility of the conductors. The insulation is constructed from Ethylene propylene rubber (EPR) which also has a semi-conducting shield added to it. The insulation for the 5000 volt wire has 100 % coverage while for the 8000 volt option the coverage is 133%.\u003c\/p\u003e\n\u003cp\u003eAn overall shield is added to prevent mechanical and electromagnetic interferences from affecting the inner parts of the cable. The overall shield is made from uncoated copper tape. The cable has an outer jacket which conceals the inner components of the cable and is made from PVC material.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eIndustrial ratings and approvals\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e It’s always advisable to buy products that have been tested and proven safe for use. Products are usually tested to ensure that they are in good condition and safe to use by the public and it also proves that the product is genuine. Many suppliers out their sell products that have not been tested by international agencies but since we at Nassau national cable care about you and your safety we ensure our products are tested. Our products are tested by the following agencies;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNational Electric Code (NEC)\u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C-30B\u003c\/li\u003e\n\u003cli\u003eICEA S-93-639\u003c\/li\u003e\n\u003cli\u003eNEMA WC74\u003c\/li\u003e\n\u003cli\u003eAEIC CS8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the above standards you can trust that our products are genuine\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhy go for the medium voltage power cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable has numerous benefits that come with it to the consumer. First and foremost this cable can be used in a wide range of applications to supply power including corrosive environments. It also has outstanding features that make it effective in performing its functions which includes durability and flexibility. This cable can also be recycled hence it can be utilized elsewhere in case it wears out which can take a lifetime.\u003c\/p\u003e\n\u003cp\u003eThis cable can be found in many electrical outlets worldwide but before you settle on a supplier it’s advisable to ensure the products are genuine. For more information on this cable and other wire products get in touch with us via our live chat on our website and we will gladly respond to your queries. I hope you found this review helpful.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION and MV105 THREE CONDUCTOR NON-SHIELDED EPR INSULATION PVC JACKET COPPER POWER CABLE 2.4kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the specific applications of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2.4kV Power Cables are suitable for corrosive environments in power circuits up to 2400V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003eMV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables also are used in similar situations, just that it can be used in power circuits up to 5,000V \u0026amp; 8,000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe main difference between bothcables lies in the fact that MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables have a ground conductor with soft bare annealed compressed copper per ASTM B-3, and with stranding of Class B per ASTM B-8 sized in accordance to UL Standard 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the insulation used for MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the power cables have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the regulations and uses of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables under specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of both thepowercables at 105°C for continuous operation, 140°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the national and international standards to which MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables conform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-93-639\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNEMA WC74\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAEIC CS8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFederal Specification J-C-30B\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521998946404,"sku":"NNC5249X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product32.png?v=1762459840","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/mv-105-power-cable-w-ground-5kv-8kv-epr-pvc-insulation-copper-tape-shield-133-100-insulation-level","provider":"NassauNationalCable","version":"1.0","type":"link"}