{"product_id":"hvteck-aluminum-3-c-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"HVTECK Aluminum 3\/C 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003eHVTECK Aluminum 3\/C 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e15kV HVTECK Cable, \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 15kV CSA Armoured Cable, 15kV Medium Voltage Cable, 15kV MV Cable, 15kV 3\/C Aluminum Cable, 3 Conductor 15kV Cable, 3\/C Aluminum HV Cable, 220 mil NLEPR Cable, NL-EPR Insulated Cable, EPR Insulated Medium Voltage Cable, Tape Shielded MV Cable, Copper Tape Shield Cable, AIA Armoured Cable, Aluminum Interlocked Armour Cable, PVC Inner Jacket Cable, PVC Jacketed Armoured Cable, 15kV Shielded Power Cable, CSA 15kV Power Cable, Hazardous Location 15kV Cable,  FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67613612900721,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/hvteck-aluminum-3-c-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","provider":"NassauNationalCable","version":"1.0","type":"link"}