{"product_id":"750-mcm-3c-type-mv-105-copper-15kv-nlepr-133-il-50-ground-aia-red-pvc-jacket","title":"750 MCM 3C Type MV-105 Copper 15kV NLEPR 133% IL 50% Ground AIA Red PVC Jacket","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46455_1.pdf?v=1755765887\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Type MV-105 Copper 15kV NLEPR 133% IL 50% Ground AIA Red PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with \"LTGG\" when CSA listed or dual UL\/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/ FT maximum sidewall pressure. The ground is sized to equal 50% of the phase conductor. Silicone free cable Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free. Silicone Free\u0026gt;\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e750 MCM 3C MV-105 15kV Copper Cable with NLEPR Insulation, 50% Ground and PVC Jacket \u003cspan style=\"font-size: 0.875rem;\"\u003eThree Conductor 15kV Copper 750 MCM 3C  Power Cable with NLEPR and 50% Grounding \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e15kV Copper Cable with 133% IL NLEPR Insulation and Red PVC Jacket \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eRed PVC Jacketed 15kV Copper 750 MCM 3C Cable with AIA Insulation and 50% Ground \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e15kV Copper Power Cable with 50% Ground, NLEPR Insulation, and PVC Jacket 750 MCM 3C \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMV-105 Copper Cable 15kV with 50% Ground and AIA Red PVC Jacket \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThree Conductor Copper 15kV Cable with NLEPR Insulation, 50% Grounding, and PVC Jacket \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e15kV Copper Cable 750 MCM 3C with NLEPR Insulation, 50% Ground, and Red PVC Outer Jacket\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eThree separate ground wires with a combined circular mil of 50% of the phase conductor. Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003eNon-hydroscopic wax paper filler\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003e Polypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eAluminum Interlocked Armor (AIA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize:\u003c\/strong\u003e 750 MCM\u003cbr\u003e• \u003cstrong\u003eNumber of Conductor:\u003c\/strong\u003e 3 + 3G\u003cbr\u003e• \u003cstrong\u003eNumber of Strands:\u003c\/strong\u003e   61\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch): \u003c\/strong\u003e0.968\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e  1.464\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation Shield (inch): \u003c\/strong\u003e 1.524\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG: \u003c\/strong\u003e  3x2\/0\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor (inch): \u003c\/strong\u003e   3.663\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):   \u003c\/strong\u003e90\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e 3.851\u003cbr\u003e• \u003cstrong\u003eCopper Weight lb\/1000ft: \u003c\/strong\u003e8624\u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e12093\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e    0.014\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft:  \u003c\/strong\u003e0.023\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Duct 90\/105°C Amp : \u003c\/strong\u003e   545\/585 \u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Air 90\/105°C Amp: \u003c\/strong\u003e 670\/745\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55746567045489,"sku":"NNC576202","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-08-22T115728.858_4f10b4b5-d294-4ccf-86bb-913d2fa795b3.png?v=1756106523","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/750-mcm-3c-type-mv-105-copper-15kv-nlepr-133-il-50-ground-aia-red-pvc-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}