{"product_id":"600-duke-single-aluminum-conductor-underground-direct-burial-600v-urd-cable-nassau-cable","title":"600 MCM Duke Single Aluminum Conductor Underground Direct Burial 600V URD Cable","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_URD_6ee323cd-0dc4-4f41-a3c4-3dc06e7e89d4.pdf?v=1722244059\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e600 MCM Duke Single Aluminum Conductor Underground Direct Burial 600V URD Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e 600 Duke Single Aluminum Conductor Underground Direct Burial 600V URD Cable: 510 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-model-slug=\"gpt-4o\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 whitespace-normal break-words text-start [.text-message+\u0026amp;]:mt-5\" dir=\"auto\" data-message-id=\"38e2a37c-cdb2-43e5-8e6d-362b5df70bd5\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert dark\"\u003e\n\u003cp data-end=\"479\" data-start=\"148\"\u003eThis single aluminum conductor URD cable is designed for primary and secondary power distribution in utility, commercial, and industrial environments. It is suitable for direct burial or duct installation in underground electrical systems and can be used in wet or dry conditions at temperatures up to 90°C.\u003c\/p\u003e\n\u003ch4 data-end=\"511\" data-start=\"481\"\u003e\u003cstrong data-end=\"509\" data-start=\"486\"\u003eSpecific Use Cases of 600 MCM Single URD:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"1075\" data-start=\"512\"\u003e\n\u003cli data-end=\"580\" data-start=\"512\"\u003ePhase conductor in underground utility distribution systems.\u003c\/li\u003e\n\u003cli data-end=\"645\" data-start=\"581\"\u003eSubstation feeders for high-capacity power transmission.\u003c\/li\u003e\n\u003cli data-end=\"711\" data-start=\"646\"\u003eGrounding and neutral conductor in substations and grids.\u003c\/li\u003e\n\u003cli data-end=\"764\" data-start=\"712\"\u003eMunicipal and industrial grid reinforcement.\u003c\/li\u003e\n\u003cli data-end=\"839\" data-start=\"765\"\u003ePower distribution for large commercial and industrial facilities.\u003c\/li\u003e\n\u003cli data-end=\"903\" data-start=\"840\"\u003eRenewable energy transmission for solar and wind farms.\u003c\/li\u003e\n\u003cli data-end=\"991\" data-start=\"904\"\u003eBackup power infrastructure for hospitals, data centers, and emergency systems.\u003c\/li\u003e\n\u003cli data-is-last-node=\"\" data-end=\"1075\" data-start=\"992\"\u003eTemporary high-load power for construction sites and industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mb-2 flex gap-3 -ml-2\" tabindex=\"0\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e600 duke aluminum urd cable, 600 duke urd direct burial cable, 600 duke direct burial electrical cable, 600 duke direct burial power cable, 600 duke aluminum direct burial cable, 600 duke single conductor wire, 600 duke southwire urd.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum 600V URD is approved to meet design, production and application standards. The following are some of the standard it has met:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eApproved by ICEA S-105-692\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-609\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-230\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAccepted by RUS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThis is an aluminum conductor cable. The conductor is designed in two forms: either concentric strand or compressed. The stranded type tends to be more flexible compared to the compressed series of aluminum conductors. The 1350-H19 series of compressed aluminum conductors are suitable for applications where flexibility is overlooked and cable rigidity is guaranteed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum 600V URD cable has black resistant cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor size\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e600\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNominal Insulation (mils)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eApprox. \u003c\/b\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1.060\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eEstimated Weight lbs.\/1000ft:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e 562\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eTotal Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 697 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 510 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27475858817124,"sku":"NNC1907X","price":5.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_2_ca433a91-f509-4663-92d5-1f1d58050a53.png?v=1762458439","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/600-duke-single-aluminum-conductor-underground-direct-burial-600v-urd-cable-nassau-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}