{"product_id":"561-10-3420-c-l-x-type-sp-os-type-itc-pltc-armored-20-shielded-pairs-16-awg-105-deg-c","title":"561-10-3420 C-L-X Type SP-OS, Type ITC\/PLTC, Armored, 20 Shielded Pairs - 16 AWG - 105 Deg. C","description":"[short] \n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8. \u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eFlame-retardant Okoseal® (PVC) per UL Standard 13 and 2250, 15 mils nominal thickness, 105°C temperature rating.\u003cbr\u003e \u003cstrong\u003eConductor Identification: \u003c\/strong\u003e Pigmented black and white in pairs, black, red and white in triads. Pair or triad assembled with left-hand lay.\u003cbr\u003e \u003cstrong\u003e Group Shield:\u003c\/strong\u003e Aluminum\/Polyester tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, two sizes smaller than the conductor. All group shields are completely isolated from each other.\u003cbr\u003e \u003cstrong\u003eCommunications Wire: \u003c\/strong\u003e22 AWG, solid, bare copper conductor, 12 mils nominal flame-retardant Okoseal insulation, 105°C rating.\u003cbr\u003e \u003cstrong\u003eAssembly: \u003c\/strong\u003ePairs or triads assembled with left hand lay. Fillers included where required to provide a round cable.\u003cbr\u003e \u003cstrong\u003eCable Shield:\u003c\/strong\u003e Aluminum\/Polyester tape over-lapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as the conductor.\u003cbr\u003e \u003cstrong\u003eInner Jacket: \u003c\/strong\u003eBlack, flame-retardant, low temperature Okoseal per UL 13 and 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.\u003cbr\u003e \u003cstrong\u003eC-L-X Sheath:\u003c\/strong\u003e A close-fitting, impervious, continuously welded and corrugated, aluminum sheath provides complete protection against moisture, liquids, and gases, has excellent mechanical strength, and provides equipment grounding through the sheath.\u003cbr\u003e \u003cstrong\u003eOuter Jacket: \u003c\/strong\u003eBlack, flame-retardant, low temperature Okoseal per UL 13 and 2250.\u003cstrong\u003e\u003cbr\u003e Classifications\u003c\/strong\u003e: UL Listed as ITC\/PLTC - Instrument Tray Cable\/Power Limited Tray Cable for use in accordance with Article 727 and Article 725 of the National Electrical Code.\u003cbr\u003e Cables comply with UL 2250 and UL 13 for PLTC, CL2 and CL3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e C-L-X Type SP-OS (Pair\/triad - Individual and Overall Shield) instrumentation cables are designed for use as instrumentation, process control, in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where maximum shielding against external interference is required, as well as shielding among groups, particularly where the cable may be subject to abnormally high current or voltage interference; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire; under raised floors or direct burial. Suitable in Class I \u0026amp; II, Division 2 or Class III, Division 2 and Class I, Zone 2 hazardous locations. Also for use as Power-Limited fire protective signaling cable (FPL) per NEC Code 760. It may be installed in both exposed and concealed work, secured to supports not greater than 6 feet apart.\u003cbr\u003e The isolated individual shields over each pair, when properly grounded, prevent crosstalk or capacitive coupling between adjacent pairs which occurs with ac signals, particularly the pulse type.\u003cbr\u003e The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.\u003cbr\u003e The C-L-X sheath provides physical protection against mechanical damage as well as complete protection against moisture or gases entering the cable.\u003cbr\u003e For dc service in wet locations X-Olene® insulation is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePasses the UL 13, IEEE 383-1974 vertical tray flame tests.\u003c\/li\u003e\n\u003cli\u003ePasses the IEEE 1202 vertical tray flame test (2 pr #18 AWG and larger).\u003c\/li\u003e\n\u003cli\u003ePasses the 210,000 BTU\/hr vertical tray flame test per ICEA T-29-520.\u003c\/li\u003e\n\u003cli\u003eUL listed for direct burial (2 PR #20 AWG and larger)\u003c\/li\u003e\n\u003cli\u003eComplete pre-packaged, factory-tested wiring system-color coded.\u003c\/li\u003e\n\u003cli\u003eC-L-X enclosure permits installation in cable tray containing light and power cables without a barrier separator.\u003c\/li\u003e\n\u003cli\u003eIndividual pairs or triads are completely isolated.\u003c\/li\u003e\n\u003cli\u003eImpervious, continuous sheath excludes moisture, gases and liquids.\u003c\/li\u003e\n\u003cli\u003eC-L-X sheath exceeds equipment grounding conductor requirements of NEC Article 250-118.\u003c\/li\u003e\n\u003cli\u003eLower installed system cost than conduit or EMT systems.\u003c\/li\u003e\n\u003cli\u003eMeets API Standards 14F \u0026amp; 14FZ.\u003c\/li\u003e\n\u003cli\u003eSuitable for low temperature installation to -40°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27553001930852,"sku":"NNC8635X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/clx-spos-armored-cable_14_54fef972-cecc-4048-98f0-9687e3da4c1f.jpg?v=1762462016","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/561-10-3420-c-l-x-type-sp-os-type-itc-pltc-armored-20-shielded-pairs-16-awg-105-deg-c","provider":"NassauNationalCable","version":"1.0","type":"link"}