{"product_id":"500-18-awg-6p-pltc-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 18 AWG 6P PLTC Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp data-mce-fragment=\"1\"\u003e[short]\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e18 AWG 6P PLTC Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eShielded Pairs with Overall Shield (STOS) tray cables are designed for low-voltage tray applications in circuits with limited power because their voltage rating is 300 V. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eShielded Pairs with Overall Shield (STOS) tray cables are dual-listed as PLTC and ITC. These abbreviations respectively correspond to the terms \"power limited tray cable\" and \"instrumentation tray cable.\" As ITC, the cable is used exclusively in 150 V circuits. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eBecause of their shielding, these cables are generally used where there has to be maximum noise rejection. They are also used in manufacturing plants, storage areas, offices, and labs with medium to low noise levels. PLTC is suitable for internal connections, audio communication, and alarm systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eShielding gives these cables protection from noise and electromagnetic interference. Another benefit of STOS 300V is its extreme flexibility. The maximum recommended operating temperature is 105°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eCable Tray, Cable Tray Types, Electrical Cable Tray, Pvc Cable Tray, wire cable tray, cable tray wire, PLTC Cable, ITC Cable, PVC Cable, Tray Instrument Cable, Tray Instrumentation Cable, STOS Cable, Low-Voltage Tray Cable, Shielded Tray Cable, Power Limited Tray Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• NEC Article 725 as PLTC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• NEC Article 727 as ITC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• UL 13 as PLTC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• UL 2250 as ITC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• NEC Article 336\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• FT4\/IEEE 1202 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• IEEE 383 Flame Test (70,000 BTU)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e• EPA 40 CFR, P. 26 C, heavy metals per Table 1, TCLP \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThe cable has annealed B bare copper conductors that meet the requirements of ASTM B-33 and B-8. The pairs are connected through concentric layers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eA flame-retardant PVC insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003ePVC is a black durable jacket resistant to moistures, flames, abrasion, chemicals, oils, sunlight, and acids. The jacket has a nylon ripcord for easier maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThe shielded triads with an overall shield assembly is made of aluminum foil or polyester shield. It provides excellent coverage thanks to tinned copper drain wire that is the same size as the conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e[\/short]\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63411785498993,"sku":"NNC21534X500","price":1545.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/226_b78a6189-5657-4746-a95a-de6477ec1102.png?v=1762470941","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/500-18-awg-6p-pltc-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","provider":"NassauNationalCable","version":"1.0","type":"link"}