{"product_id":"500-1-3c-18-9c-6-awg-ground-type-tc-tc-er-jp-aluminum-generator-cable-black","title":"500' 1\/3C + 18\/9C 6 AWG Ground Type TC\/TC-ER-JP Aluminum Generator Cable Black","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Generator_AL.pdf?v=1681293071\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e1\/3C + 18\/9C 6 AWG Ground Type TC\/TC-ER-JP Aluminum Generator Cable Black\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA multi-conductor all-in-one cable for connecting a 17kW – 24kW generator to a transfer switch. A multi-conductor\u003cspan data-mce-fragment=\"1\"\u003e all-in-one cable for connecting a generator to a transfer switch. JP (Joist Pull) rated per the 2017 NEC 336.10(9). Black jacket and color-coded inner conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGenerator Cable, Type TC\/TC-ER-JP, Multi-Conductor Generator Cable, PVC Generator Cable, Type TC Cable, Type TC-ER Wire, Generator Wire, joist Pull Generator Cable, Aluminum Generator Cable, 17kW Generator Cable, 24kW Generator Cable, 1\/3C + 18\/9C 6 W\/G Cable, Black Generator Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eConstruction:\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e• Element 1: Aluminum 8000 series\u003cbr data-mce-fragment=\"1\"\u003e• Element 2: Annealed bare Aluminum Class K\u003cbr data-mce-fragment=\"1\"\u003e• Element 3: Aluminum 8000 series\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e• Element 1, 2 \u0026amp; 3: Polyvinylchloride (PVC) \u0026amp; Nylon\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e• Sunlight resistant and direct burial approved PVC with ripcord rated 90°C wet or dry per UL 1277\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAll 3 Elements or Conductors are cabled together with Non-Hygroscopic Polypropylene fillers as required for a circular cross-section with a clear mylar binder tape and jacketed.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e• Element 1: Black, White, Red\u003cbr data-mce-fragment=\"1\"\u003e• Element 2: Black, Red, Yellow, Yellow\/Black, Blue, White, White\/Blue, Purple, Purple\/Black\u003cbr data-mce-fragment=\"1\"\u003e• Element 3: Green Ground\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eUL Listed as TC-ER-JP per UL Standard 1277\u003cbr data-mce-fragment=\"1\"\u003e• Rated 90°C wet or dry to meet UL 83 for THHN\/THWN\u003cbr data-mce-fragment=\"1\"\u003e• Meets cold bend test at -40°C\u003cbr data-mce-fragment=\"1\"\u003e• ICEA S-73-532. ICEA S-95-658, where applicable\u003cbr data-mce-fragment=\"1\"\u003e• Meets UL 1581 \u0026amp; 1202 (FT-4) 70,000 BTU\/HR \u0026amp; ICEA T-29-520 210,000 BTU\/HR requirements\u003cbr data-mce-fragment=\"1\"\u003e• REACH compliant per Regulation (EC) No 1907\/2006 (233) Updated January 17, 2023\u003cbr data-mce-fragment=\"1\"\u003e• Cable is suitable for use in Class I Division 2 hazardous locations\u003cbr data-mce-fragment=\"1\"\u003e• Element 1 \u0026amp; 2 conductors pass UL VW-1 flame test, rated THWN\/VW-1\u003cbr data-mce-fragment=\"1\"\u003e• ASTM B3, B8, B174, B787\u003cbr\u003e• UL approved for Direct Burial \u0026amp; Sunlight Resistant\u003cbr\u003eApplications\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSize:\u003c\/strong\u003e 1 AWG (3 Conductors), 18 AWG (9 Conductors)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eGround Wire Size:\u003c\/strong\u003e 6 AWG\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eJacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePolyvinylchloride (PVC) \u0026amp; Nylon\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eJacket Color:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eBlack\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eOutside Diameter:\u003c\/strong\u003e 1.086 inches\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight lbs\/kft: \u003c\/strong\u003e675 lbs\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eAllowable Ampacity:\u003c\/strong\u003e 100 Amps \u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e***THIS MATERIAL IS NON-RETURNABLE***\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAll values are nominal and subject to correction.\u003cbr data-mce-fragment=\"1\"\u003e*Ampacity according to NEC 310.15(B)(16) @30°C THWN 75°C insulated wires.\u003cbr data-mce-fragment=\"1\"\u003e**Installations shall follow NEC, applicable correcting factors shall be considered when conditions vary.\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55633873011057,"sku":"NNC200163","price":3375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1-03TCGAL-18-06-VN.jpg?v=1762520742","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/500-1-3c-18-9c-6-awg-ground-type-tc-tc-er-jp-aluminum-generator-cable-black","provider":"NassauNationalCable","version":"1.0","type":"link"}