{"product_id":"5-inch-electrical-cable-heat-shrink-termination-caps-2000-2500mcm-68240","title":"5 Inch Electrical Cable Heat Shrink Termination Caps 2000-2500MCM 68240","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/97017-Spec_1fce032e-657b-429e-beb9-3da5be9424fe.pdf?v=1781509666\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• The 5 Inch Electrical Cable Heat Shrink Termination Caps 2000–2500 MCM are high-performance end sealing solutions designed to protect the exposed ends of extra-large electrical cables from moisture, contamination, and environmental damage.\u003cbr\u003e• Specifically engineered for 2000–2500 MCM conductors, these heat shrink termination caps create a secure, insulated barrier that helps maintain cable integrity during storage, transportation, installation, and temporary service applications.\u003cbr\u003e• Their heavy-duty construction makes them ideal for utility, industrial, marine, renewable energy, and high-voltage power distribution applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Shrink Cable Termination Caps, 5 Inch Heat Shrink End Caps, 2000–2500 MCM Cable End Seal Caps, Electrical Cable Heat Shrink End Caps, Heavy-Duty Heat Shrink Cable Caps, Power Cable End Protection Caps, Heat Shrink Cable Closure Caps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 74.4526%; height: 208.531px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 32.1875px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 32.1875px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e\u003cspan\u003eHeat Shrink End Caps\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCable Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e2000-2500MCM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e5\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDiameter\u003cbr\u003eBefore Shrinking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e2.75\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDiameter\u003cbr\u003eAfter Shrinking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e1.00\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eWall\u003cbr\u003eThickness\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e0.08\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.0199%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.4826%; text-align: center; height: 19.5938px;\"\u003e68240\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Designed for 2000–2500 MCM Conductors Specifically sized to fit extra-large power cables used in demanding utility and industrial applications.\u003cbr\u003e• 5-Inch Extended Coverage Provides additional length for enhanced sealing and protection of cable terminations and exposed cable ends.\u003cbr\u003e• Heat-Activated Shrink Technology Shrinks uniformly when heated to create a secure, tight-fitting seal around the cable jacket.\u003cbr\u003e• Superior Environmental Protection Helps prevent moisture intrusion, dust accumulation, dirt ingress, and contamination that could affect cable performance.\u003cbr\u003e• Heavy-Duty Construction Manufactured from durable heat shrink material designed to withstand harsh operating conditions and mechanical stress.\u003c\/p\u003e","brand":"Morris","offers":[{"title":"Default Title","offer_id":64055634297201,"sku":"68240","price":63.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/LCDX20-38D-X_33_b84d4cd2-78b3-4126-bc8f-292983ec7faf.jpg?v=1781517420","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/5-inch-electrical-cable-heat-shrink-termination-caps-2000-2500mcm-68240","provider":"NassauNationalCable","version":"1.0","type":"link"}