{"product_id":"350-mcm-hvteck-copper-115-mil-nlepr-cb-aia-5kv-133-il-orange-pvc-jacket-csa","title":"350 MCM HVTECK Copper 115 mil NLEPR CB AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SP_1.pdf?v=1756356882\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM HVTECK Copper 115 mil NLEPR CB AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant Single Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Concentric Bond, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"143\" data-end=\"200\"\u003e350 MCM HVTECK 1\/C Copper Cable, 5kV NLEPR with Orange PVC Jacket HVTECK 1-Conductor Copper Cable, 115 mil NLEPR, 5kV, CSA Rated 350 MCM HVTECK 115 mil Copper Cable, 5kV NLEPR, AIA Orange PVC Jacket 1\/C Copper 350 MCM HVTECK Cable, 115 mil, 5kV with Orange PVC Jacket 5kV Copper Cable, 1 Conductor, NLEPR, 115 mil, with AIA Orange PVC Jacket 350 MCM HVTECK 1\/C 5kV Copper Cable, CSA Certified, 133% Insulation HVTECK 1-Copper 115 mil 5kV NLEPR Cable, Orange PVC Coating HVTECK 1\/C Copper 5kV NLEPR Cable with 133% Insulation, AIA Rating\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003e Tape Shield:\u003cbr\u003e\u003c\/strong\u003e5 mil tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConcentric Shield: \u003cbr\u003e\u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNeutral Separator\u003c\/strong\u003e: \u003cbr\u003eMylar tape\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Jacket:\u003cbr\u003e\u003c\/strong\u003ePVC inner jacke\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmour:\u003c\/strong\u003e\u003cbr\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eOrange Polyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e 0.661\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e  0.917\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil:  \u003c\/strong\u003e115\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch): \u003c\/strong\u003e 0.977\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Concentric Neutral\u003c\/strong\u003e \u003cstrong\u003eNo. x AWG:\u003c\/strong\u003e  21x14\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e  80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 1.632\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.745\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft: \u003c\/strong\u003e1365\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  2313\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e  0.031\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.041 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 537\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp: \u003c\/strong\u003e456\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e588055\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761135960433,"sku":"NNC588055","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_1_4f157205-32e0-4285-b2bf-684d3b56728d.png?v=1756356496","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/350-mcm-hvteck-copper-115-mil-nlepr-cb-aia-5kv-133-il-orange-pvc-jacket-csa","provider":"NassauNationalCable","version":"1.0","type":"link"}