{"product_id":"350-kcmil-tinned-copper-cable-with-sc-epr-insulation-and-ep-rubber-jacket-cable","title":"350 kcmil Tinned Copper Cable with SC-EPR Insulation and EP Rubber Jacket Cable","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"Polaris-Header-Title\"\u003e\u003cspan class=\"Polaris-Text--root Polaris-Text--headingLg Polaris-Text--bold\"\u003e350 kcmil Tinned Copper Cable with SC-EPR Insulation and EP Rubber Jacket Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"Polaris-Bleed\"\u003e\n\u003cdiv class=\"Polaris-InlineStack\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 kcmil 37X Compressed Class B Strand Tinned Copper Extruded Semiconducting (SC-EPR) 115 Extruded Ethylene Propylene Rubber. 1\/C 350 37X TINNED COPPER\u003cbr\u003e-SS-115 OKOGURD EPR - 5KV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350.0 KCMIL 37X cable, 350.0 KCMIL cable, 350.0 KCMIL Class B Strand Tinned Copper, 350.0 KCMIL 37 Ethylene Propylene Rubber.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-mce-style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e350 kcmil 37X Compressed Class B Strand Tinned Copper\u003c\/p\u003e\n\u003ch4\u003eCONDUCTOR SCREEN:\u003c\/h4\u003e\n\u003cp\u003eExtruded Semiconducting (SC-EPR)\u003c\/p\u003e\n\u003ch4\u003eINSULATION:\u003c\/h4\u003e\n\u003cp\u003e115 Extruded Ethylene Propylene Rubber OKOGUARD®\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli data-mce-style=\"font-weight: 400;\"\u003e\n\u003cb\u003eConductor Diameter (in.): \u003c\/b\u003e0.664\u003c\/li\u003e\n\u003cli data-mce-style=\"font-weight: 400;\"\u003e\n\u003cstrong\u003eCond. Screen \u003cb\u003eDiameter (in.): \u003c\/b\u003e\u003c\/strong\u003e0.708\u003c\/li\u003e\n\u003cli data-mce-style=\"font-weight: 400;\"\u003e\n\u003cstrong\u003eInsulation Diameter (in.):  \u003c\/strong\u003e0.948\u003c\/li\u003e\n\u003cli data-mce-style=\"font-weight: 400;\"\u003eCable Weight (lbs.\/M'): 1277\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003caddress\u003e\u003cspan style=\"font-size: 1em;\" data-mce-style=\"font-size: 1em;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/address\u003e\u003caddress\u003e\u003c!--\n\u003cstrong style=\"font-size: 12px;\"\u003eApplication:\u003c\/strong\u003e\u003c\/address\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 12px;\"\u003eAppropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 12px;\"\u003eHas a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 12px;\"\u003eShield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShielded wires of six ridged copper which are embedded longitudinally in an exterior semi-conducting CPE jacket per ICEA S-97-682.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSunlight-resistant CPE per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003caddress\u003eICEA S-93-639\u003c\/address\u003e\u003c\/li\u003e\n\u003cli\u003e\u003caddress\u003eNEMA WC74\u003c\/address\u003e\u003c\/li\u003e\n\u003cli\u003e\u003caddress\u003eAEIC CS8\u003c\/address\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n--\u003e\u003c\/address\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":44789150449818,"sku":"NNC5219X35056","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_2_82429cc7-7d96-4327-8cdf-dcd02ce68d17.png?v=1762996329","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/350-kcmil-tinned-copper-cable-with-sc-epr-insulation-and-ep-rubber-jacket-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}