{"product_id":"32a-480vac-reefer-sharing-unit-two-port-terminal-outlet","title":"32A 480VAC Reefer Sharing Unit Two Port Terminal Outlet","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/s_2213-04sa.pdf?v=1748578737\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp data-end=\"135\" data-start=\"73\"\u003e\u003cstrong data-end=\"135\" data-start=\"73\"\u003e32A 480VAC Reefer Sharing Unit – Port Terminal Application\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"367\" data-start=\"137\"\u003eMaximize reefer capacity and optimize power usage with this rugged Reefer Sharing Unit. Designed for port terminal environments, this unit allows \u003cstrong data-end=\"366\" data-start=\"283\"\u003etwo refrigerated containers (reefers) to share a single 32A 480VAC power outlet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul data-end=\"809\" data-start=\"369\"\u003e\n\u003cli data-end=\"535\" data-start=\"369\"\u003e\n\u003cp data-end=\"535\" data-start=\"371\"\u003e\u003cstrong data-end=\"399\" data-start=\"371\"\u003eAutomatic Load Switching\u003c\/strong\u003e: When two reefers are connected, the unit alternates power between them. If only one reefer is connected, it receives continuous power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"660\" data-start=\"536\"\u003e\n\u003cp data-end=\"660\" data-start=\"538\"\u003e\u003cstrong data-end=\"557\" data-start=\"538\"\u003eManual Override\u003c\/strong\u003e: An integrated A-B switch allows operators to manually select which reefer receives power when needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"809\" data-start=\"661\"\u003e\n\u003cp data-end=\"809\" data-start=\"663\"\u003e\u003cstrong data-end=\"683\" data-start=\"663\"\u003eEfficiency Boost\u003c\/strong\u003e: Effectively doubles frozen-load capacity using existing infrastructure—typically pays for itself in just one ocean crossing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"840\" data-start=\"811\"\u003e\u003cstrong data-end=\"840\" data-start=\"811\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1210\" data-start=\"841\"\u003e\n\u003cli data-end=\"943\" data-start=\"841\"\u003e\n\u003cp data-end=\"943\" data-start=\"843\"\u003e\u003cstrong data-end=\"857\" data-start=\"843\"\u003eReceptacle\u003c\/strong\u003e: 32A 480VAC (380\/440VAC, 50\/60 Hz), 3-phase, 3-wire + ground, 3h per IEC 60309-1 \u0026amp; -2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1053\" data-start=\"944\"\u003e\n\u003cp data-end=\"1053\" data-start=\"946\"\u003e\u003cstrong data-end=\"954\" data-start=\"946\"\u003ePlug\u003c\/strong\u003e: 32A 480VAC pin \u0026amp; sleeve (380\/440VAC, 50\/60 Hz), 3-phase, 3-wire + ground, 3h per IEC 60309-1 \u0026amp; -2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1125\" data-start=\"1054\"\u003e\n\u003cp data-end=\"1125\" data-start=\"1056\"\u003e\u003cstrong data-end=\"1077\" data-start=\"1056\"\u003ePower Connections\u003c\/strong\u003e: Interlocked outlets and male plug as specified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1210\" data-start=\"1126\"\u003e\n\u003cp data-end=\"1210\" data-start=\"1128\"\u003e\u003cstrong data-end=\"1142\" data-start=\"1128\"\u003ePower Cord\u003c\/strong\u003e: 10 ft (3 m) heavy-duty SOOW 10\/4 cord, oil- and sunlight-resistant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"1388\" data-start=\"1212\"\u003eBuilt for reliability and safety, this Reefer Sharing Unit is an ideal solution for terminals looking to expand reefer handling capacity without costly infrastructure upgrades.\u003c\/p\u003e\n\u003ch4\u003eAlso known as:\u003c\/h4\u003e\n\u003cp\u003eReefer \u003cspan\u003eSharing Units, RSU modular, 32 A RSU modular, 32A Reefer terminal unit, 480V alternative current port.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eProduct Details:\u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"width: 36.3478%; height: 144.094px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6601%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.5568%; height: 19.5938px;\"\u003eType 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42.0938px;\"\u003e\n\u003ctd style=\"width: 48.6601%; height: 42.0938px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.5568%; height: 42.0938px;\"\u003eNEMA 4X fi berglass reinforced polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.6601%; height: 39.1875px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.5568%; height: 39.1875px;\"\u003e23 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFeatures:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003ePower two reefers from one power outlet – alternately powers each container when two reefers are connected. Continuously powers one reefer if only one is connected\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eTwo high visibility LED lights to indicate which outlet is energized\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOverride switch (A-B switch) to manually switch power to either reefer\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eEffectively doubles the frozen-load capacity; pays for itself in one ocean crossing\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eThe (2) interlocked outlets cannot be energized until plug is inserted \u0026amp; the collar is made-up\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eChoice of outlet configuration, snap or screw cover, handle or hanger\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eFurnished with fixed 4-hour timer (other timer settings available).\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eApprovals:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL Listed receptacles\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL Listed plug \u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eGL Certified.\u003c\/p\u003e","brand":"ESL Power","offers":[{"title":"Default Title","offer_id":55254056599921,"sku":"2213-04SA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2213-04SA.png?v=1763025417","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/32a-480vac-reefer-sharing-unit-two-port-terminal-outlet","provider":"NassauNationalCable","version":"1.0","type":"link"}