{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-260-mil-25-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum EPR cable, 3\/0 AWG High voltage underground cable, 5 kV to 46 kV aluminum cable, EPR insulated MV-90 cable, 3\/0 AWG EPR LLDPE cable, 3\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.34\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1068\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55161424281969,"sku":"NNCV03\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-260-mil-25-kv","provider":"NassauNationalCable","version":"1.0","type":"link"}