{"product_id":"2u-monitored-econnect-ea-3462-e","title":"2U Monitored eConnect EA-3462-E","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/eCONNECT_PDU_MONITORED.pdf?v=1692096067\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" style=\"width: 94.9585%;\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003ePlug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003eIEC60309 32A 1P+N+E\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eOutlets\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003e(18) C13 Locking + (6) C19 Locking Outlets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eVolts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003e220-240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003eSingle-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eAMP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003ekW Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003e6.1(UL) \/ 7.7(CE)kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eCabinet Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003e2U \u0026amp; Higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eFinish\/ Color\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003eGlacier White\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 42%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cb data-mce-fragment=\"1\"\u003ePart No.\u003c\/b\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 47.3749%; text-align: center;\"\u003e\u003cspan\u003eEA-3462-E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitored eConnect PDUs provide remote power monitoring to the input and branch circuit level, making it possible to obtain and manage power consumption at the cabinet level\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eReduced Networking Costs and Complexity – Secure Array allows the use of a single IP address for up to 48 connected PDUs (32 when electronic locks are integrated). Second IP address for the entire array provides failover capability\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eResistance to High Temperature – Market-leading temperature ratings of up to 149°F (65°C) ensures reliability when mounted toward hot aisles\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eSimplified Load Balancing – Phase-balance outlets on three-phase models ensure equal loading across all phases; allows use of shorter equipment power cords for better cable and airflow management\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eNo Accidental Disconnections – Patent-pending, low-profile locking outlets prevent accidental disconnections without requiring special cords\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eEasy Identification of Failover Unit – Redundancy Pack includes 2 PDUs (one in Black and one in Glacier White) for easy identification of the primary and secondary unit\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eElectronic Lock Integration – Patented technology seamlessly integrates PDU, environmental sensors and electronic locks into a single hardware and software solution\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eGigabit Ethernet – Ensures compatibility with enterprise routers and switches\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLatest UL Compliance – Meets UL and IEC 62368 for compliance with new listing requirements for North America and the European Union\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eCabinet Pre installation – Complete ecosystem ships ready for IT equipment integration. Saves deployment time and reduces packaging waste\u003c\/p\u003e","brand":"CPI - Big","offers":[{"title":"Default Title","offer_id":43838425432218,"sku":"EA-3462-E","price":1621.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/44_79f982be-b7b5-4278-98b3-d4c312c275fa.png?v=1762978521","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/2u-monitored-econnect-ea-3462-e","provider":"NassauNationalCable","version":"1.0","type":"link"}