{"product_id":"267-17-2412-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-12-triads-overall-shield-type-p-os-16-awg","title":"267-17-2412 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  12 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2412 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 12 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2412 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2412\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 12\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.19 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.11 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 698\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 778\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562503143524,"sku":"NNC9311X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_dff0fcdd-f00c-4cf7-8c2d-9272fb1a518b.jpg?v=1762462704","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/267-17-2412-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-12-triads-overall-shield-type-p-os-16-awg","provider":"NassauNationalCable","version":"1.0","type":"link"}