{"product_id":"250-mcm-3c-type-mv-105-copper-5-8kv-nlepr-insulation-133-100-il-armor-x-yellow-pvc-jacket","title":"250 MCM 3C Type MV -105 Copper 5\/8kV NLEPR Insulation 133\/100% IL ARMOR-X Yellow PVC Jacket","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/222222_3.pdf?v=1755857387\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Type MV -105 Copper 5\/8kV NLEPR Insulation 133\/100% IL ARMOR-X Yellow PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe 5KV ARMOR-X MC HL are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Suitable for VFD application. Rated for 1000 lbs.\/FT maximum sidewall pressure Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Aluminum Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Suitable for VFD Applications. Type MC HL. Silicone Free\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"128\" data-start=\"87\"\u003e250 MCM 3C MV-105 Three-Conductor Copper Cable 5\/8 kV Three Conductor Cable with NLEPR Insulation 250 MCM 3C Medium Voltage Three-Conductor Copper Cable with Armor-X Protection 133\/100% Insulation, Three-Conductor Copper Cable with Yellow PVC Jacket 5\/8 kV NLEPR Insulated Copper Cable with Armor-X, Yellow PVC Jacket 250 MCM 3C Medium Voltage Copper Cable with IL Armor-X and Yellow PVC Jacket\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003eWax paper filler\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003e Polypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Welded Aluminum Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cstrong\u003eSize: \u003c\/strong\u003e250 MCM\u003cbr\u003e•\u003cstrong\u003e Number of Conductor: \u003c\/strong\u003e3 + 3G\u003cbr\u003e• \u003cstrong\u003eNumber of Strands: \u003c\/strong\u003e37\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch):\u003c\/strong\u003e    0.558\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation (inch):\u003c\/strong\u003e  0.818\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 0.878\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e  3x6\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor (inch):\u003c\/strong\u003e    2.290\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil)\u003c\/strong\u003e:  75\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e  2.440 \u003cbr\u003e• \u003cstrong\u003eCopper Weight lb\/1000ft:\u003c\/strong\u003e2800\u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e  4692\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.043\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft: \u003c\/strong\u003e    0.056\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Duct 90\/105°C Amp :\u003c\/strong\u003e   290\/315\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Air 90\/105°C Amp: \u003c\/strong\u003e320\/355\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e890641\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55752238563697,"sku":"NNC890641","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_5.png?v=1755856561","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/250-mcm-3c-type-mv-105-copper-5-8kv-nlepr-insulation-133-100-il-armor-x-yellow-pvc-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}