{"product_id":"19-awg-2c-helukabel-16026-tronic-cy-liy-cy-pvc-data-cable","title":"19 AWG 2C Helukabel 16026 TRONIC-CY (LiY-CY) PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M20139_EN_GB_2.pdf?v=1765435336\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 2C Helukabel 16026 TRONIC-CY (LiY-CY) PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as control and signal cables in the milliampere range for computer systems, control devices, scales etc. Due to its extremely small outer-Ø, it is especially suitable for subminiature plugs, electronic devices etc. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e19 AWG 2C Helukabel TRONIC-CY cable, LiY-CY shielded data cable, TRONIC-CY PVC data wire, Helukabel PVC data cable, LiY-CY control signal cable, Screened PVC data cable, Helukabel LiY-CY cable, Shielded control cable 0.14mm², 19 AWG 2C EMC shielded data cable, 19 AWG 2C Helukabel DIN 47100 cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current\u003cbr\u003einstallation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003c\/strong\u003e\u003cbr\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003c\/strong\u003e\u003cbr\u003e0.14 - 0.25 mm²: 800 V\u003cbr\u003e0.34 - 1.5 mm²: 1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e \u003cbr\u003eat 800 Hz\u003cbr\u003e0.14 - 0.25 mm²: approx. 100\u003cbr\u003epF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150\u003cbr\u003epF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz\u003cbr\u003e0.14 - 0.25 mm²: approx. 200\u003cbr\u003epF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 270\u003cbr\u003epF\/m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003c\/strong\u003e\u003cbr\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius \u003c\/strong\u003e\u003cbr\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRONIC-CY (LiY-CY)\u003cbr\u003e\u003c\/strong\u003eBraided screen of tinned copper wires\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Drain wire, tinned copper\u003cbr\u003e• Screen:\u003cbr\u003e1 core(s): helically wound tinned copper wires, approx. coverage 85 %\u003cbr\u003e2 - 61 core(s): braided screen of tinned copper wires, approx. coverage 85 %\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e19 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 0.75\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 5.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e38.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e59.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62812214722929,"sku":"NNC16026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-Photoroom_2_21bad313-ee5b-4cbe-aa34-7e2c52c154cd.png?v=1765435725","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/19-awg-2c-helukabel-16026-tronic-cy-liy-cy-pvc-data-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}