{"product_id":"15a-three-pole-240v-10kaic-ch-thermal-magnetic-circuit-breaker-chb315","title":"15A Three Pole 240V 10kAIC CH Thermal Magnetic Circuit Breaker CHB315","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_079b9f25-881c-4e9d-bad6-77fb3ae7f350.pdf?v=1788772977\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 28.1416%; height: 485.594px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 48.125px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 48.125px;\"\u003e\u003cstrong\u003eUsed with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"specification-value\" style=\"width: 51.6234%; height: 48.125px;\"\u003e\n\u003cdiv class=\"module-table__value value-type-default\" style=\"text-align: center;\"\u003e\u003cspan class=\"specification-value-secondary\"\u003e\u003cspan\u003eCH Loadcenters\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAmperage Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e15A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e240 V - 240 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 58.7812px;\"\u003e\u003cstrong\u003eCircuit breaker type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 58.7812px;\"\u003e\u003cspan\u003eCHB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInterrupt rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e10 kAIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eWire size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003e#14-8 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003eThree-pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 97.9688px;\"\u003e\n\u003ctd style=\"width: 47.0492%; text-align: center; height: 97.9688px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6234%; text-align: center; height: 97.9688px;\"\u003e\u003cspan\u003eCircuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-3 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eCH Thermal Magnetic Circuit Breaker\u003c\/strong\u003e is a reliable circuit protection device designed to protect electrical systems from \u003cstrong\u003eoverloads and short circuits\u003c\/strong\u003e. It combines thermal and magnetic trip mechanisms to provide dependable protection by automatically disconnecting the circuit when excessive current or fault conditions occur\u003c\/p\u003e\n\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003eFeatures :\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e• Thermal-magnetic protection for overload and short-circuit protection\u003c\/p\u003e\n\u003cp\u003e• Compatible with Eaton Type CH Loadcenters\u003c\/p\u003e\n\u003cp\u003e• Plug-on design for easy installation\u003c\/p\u003e\n\u003cp\u003e• Available in single-pole, two-pole, and three-pole configurations\u003c\/p\u003e\n\u003cp\u003e• UL 489 listed for circuit breaker safety standards\u003c\/p\u003e\n\u003cp\u003e• 120\/240V applications with up to 10 kAIC interrupt rating (depending on model)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":64554810081649,"sku":"CHB315","price":706.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/67_57ee1eb1-8ded-44c4-a922-cfcee5a4754f.png?v=1788772774","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/15a-three-pole-240v-10kaic-ch-thermal-magnetic-circuit-breaker-chb315","provider":"NassauNationalCable","version":"1.0","type":"link"}