{"product_id":"14-awg-tray-black-control-cable-hw15101419","title":"14 AWG Tray Black Control Cable HW15101419","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17886478cdd5398428cf57163243a916469549be_1__removed.pdf?v=1725356156\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" style=\"width: 40.6934%;\" width=\"100%\" data-mce-style=\"width: 81.77%;\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 39.1875px;\"\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 50.2092%; text-align: center; height: 39.1875px;\"\u003e\u003cspan\u003eBare Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eNumber of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 39.1875px;\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 39.1875px;\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 39.1875px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 39.1875px;\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 58.7812px;\"\u003e\u003cstrong\u003eOverall Diameter Inches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 58.7812px;\"\u003e0.687\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.954%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.2092%; text-align: center; height: 19.5938px;\"\u003e396\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDESCRIPTION:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e0.68 in. O.D. General purpose 600 volt control cable for use in power, control and lighting circuits in a broad range of commercial and industrial applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eGeneral purpose cable for use in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for installation in raceways, open\u003cbr\u003eair, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations. UL approved for use in continuous\u003cbr\u003eoperation at 90°C in wet or dry locations, 105°C for emergency overload conditions, and 150°C for short circuit conditions. Exposed Run (ER) rating available upon request.\u003cbr\u003eCold bend -25°C per UL 1277.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSoft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eFlame-retardant PVC per UL Standard 83 for Type THHN or THWN wire\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eINSULATION JACKET:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eClear nylon per UL Standard 83 for Type THHN or THWN wire\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFLAME TESTS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e • \u003c\/strong\u003eIEEE 383 (70,000 BTU\/hr) Flame Test\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eICEA (210,000 BTU\/hr) Flame Test\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSTANDARDS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eAs permitted for non-power-limited fire alarm circuits as defined in NEC Article 760.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eUL listed for exposed runs for cables with 3 or more conductors when installed in accordance with NEC Article 336\u003c\/p\u003e","brand":"Berk-Tek","offers":[{"title":"Default Title","offer_id":44654012170394,"sku":"HW15101419","price":2.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/9_528eb505-d61c-45e3-b629-bf89b7d60618.png?v=1762994873","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/14-awg-tray-black-control-cable-hw15101419","provider":"NassauNationalCable","version":"1.0","type":"link"}