{"product_id":"134-23-3703-3-0-awg-1c-stranded-aluminum-shielded-epr-okoguard-okoseal-pvc-mv-105-5kv-133-8kv-100-power-cable","title":"134-23-3703 3\/0 AWG 1C Stranded Aluminum Shielded EPR Okoguard Okoseal PVC MV-105 5KV-133% 8KV-100% Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-61.pdf?v=1712743156\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e134-23-3703 3\/0 AWG 1C Stranded Aluminum Shielded EPR Okoguard Okoseal PVC MV-105 5KV-133% 8KV-100% Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 134-23-3703 3\/0 AWG 1C Stranded Aluminum Shielded EPR Okoguard Okoseal PVC MV-105 5KV-133% 8KV-100% Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis particular model of MV-105 cable is designed with a 3\/0 AWG single conductor, utilizing stranded aluminum for effective power transmission. The cable's insulation is made from Ethylene Propylene Rubber (EPR), known for its excellent dielectric strength and thermal properties. The Okoguard and Okoseal PVC jacketing provide additional protection and durability. The ratings \"5KV-133%\" and \"8KV-100%\" denote the cable's voltage capabilities and insulation levels, indicating its suitability for specific medium voltage applications.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 3\/0 AWG MV-105 Power Cable\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e EPR-Insulated Aluminum Shielded Power Cable\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Medium Voltage Single Conductor Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eOkoguard shielded Okoclear-TS Type MV-105 power cables are recommended for use as\u003cbr data-mce-fragment=\"1\"\u003efeeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to\u003cbr data-mce-fragment=\"1\"\u003esunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eMay be installed in cable trays where permitted by NEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eIEEE 1202 or UL 1685 for fire and smoke performance\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eICEA S-93-639\/NEMA WC 74 for 5-35 kV power cables\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL 1072 for medium voltage power cables\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, CSA C68.10, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, CSA C68.10, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded semiconduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEAS-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, CSA C68.10, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\u003cbr data-mce-fragment=\"1\"\u003eand CSA C68.10 for Type II crosslinked polyolefin jackets.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003cbr data-mce-fragment=\"1\"\u003eCSA C68.10 listed as FT4-ST1, HALOGEN-FREE, SR, LTDD (-25C), and TC-ER.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cbr data-mce-fragment=\"1\"\u003e• 105°C continuous operating temperature.\u003cbr data-mce-fragment=\"1\"\u003e• 140°C emergency rating.\u003cbr data-mce-fragment=\"1\"\u003e• 250°C short circuit rating\u003cbr data-mce-fragment=\"1\"\u003e• Excellent corona resistance.\u003cbr data-mce-fragment=\"1\"\u003e• Exceptional resistance to “treeing”.\u003cbr data-mce-fragment=\"1\"\u003e• Screens are clean stripping.\u003cbr data-mce-fragment=\"1\"\u003e• Exceptional resistance to moisture.\u003cbr data-mce-fragment=\"1\"\u003e• Resistant to most oils, acids, and alkalis.\u003cbr data-mce-fragment=\"1\"\u003e• UL listed: MV-105, Sunlight Resistant, Cable Tray Use, and Oil Res I \u0026amp; II.\u003cbr data-mce-fragment=\"1\"\u003e• Passes the UL \u0026amp; IEEE 383-1974 and FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 3\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 85.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.72\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.97\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 24.6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 558 \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (1) Conduit in Air:\u003c\/strong\u003e 225\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (2) Underground Duct:\u003c\/strong\u003e 215\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Tray(3):\u003c\/strong\u003e 300\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 134-23-3703\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44692856766618,"sku":"134-23-3703","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_87061557-bd0e-42eb-aa1b-75ff5b5021dd.png?v=1759827758","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/134-23-3703-3-0-awg-1c-stranded-aluminum-shielded-epr-okoguard-okoseal-pvc-mv-105-5kv-133-8kv-100-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}