{"product_id":"120-277v-occupancy-sensor-with-integrated-photocell-mid-range-included-white-odc04-idw","title":"Leviton 120-277V Occupancy Sensor With Integrated Photocell Mid Range Included White ODC04-IDW","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/LEVITON_10_1_29da8619-eecf-4410-ad43-c7a1ac970c8d.pdf?v=1706771923\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003eAbout:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Occupancy sensors are widely used to automatically control lighting systems by turning lights on when occupancy is detected and off when the space is unoccupied, contributing to energy savings.\u003cbr data-mce-fragment=\"1\"\u003e• Occupancy sensors are employed in security systems to detect movement within restricted or sensitive areas, triggering alarms or surveillance systems.\u003cbr data-mce-fragment=\"1\"\u003e• PIR sensors detect changes in infrared radiation, making them suitable for applications where heat-emitting sources, such as the human body, are present.\u003cbr data-mce-fragment=\"1\"\u003e• Occupancy sensors can be ceiling-mounted, wall-mounted, or integrated into light fixtures, depending on the application and desired coverage area.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAlso known as:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eMotion Sensor, Motion Detector, Presence Detector, Human Presence Sensor, Activity Sensor, PIR Sensor, Lighting Control Sensor, Occupancy Sensor.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Product Type: Occupancy Sensor and Photocell\u003cbr data-mce-fragment=\"1\"\u003e• Mounting Type: Ceiling Mount\u003cbr data-mce-fragment=\"1\"\u003e• Voltage: 120\/230\/277V\u003cbr data-mce-fragment=\"1\"\u003e• Feature: PIR Line Voltage Dual Relay\u003cbr\u003e• Sensor Type: Occupancy, Photocell\u003cbr data-mce-fragment=\"1\"\u003e• Frequency: 50\/60Hz\u003cbr data-mce-fragment=\"1\"\u003e• Color: White\u003cbr data-mce-fragment=\"1\"\u003e• UPC Code:• 078477539965\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Uses industry-exclusive digital (4 element) PIR circuitry for fewer false triggers from unwanted sources such as HVAC systems. A Fresnel lens establishes dozens of detection zones requiring the heat source to move from one zone to another to trigger the sensor.\u003cbr data-mce-fragment=\"1\"\u003e• Auto-Adapting: Time delay and sensitivity are continually adjusted to occupancy pattern of use\u003cbr data-mce-fragment=\"1\"\u003e• Configurable for Manual ON\/Auto OFF or Auto ON\/Auto OFF\u003cbr data-mce-fragment=\"1\"\u003e• Delayed OFF Timer: The sensor will turn lights OFF if no motion is detected after a specified time\u003cbr data-mce-fragment=\"1\"\u003e• Exclusive Walk-through Feature: Provides increased energy savings by not leaving the lights ON for an extended period after only momentary occupancy\u003cbr data-mce-fragment=\"1\"\u003e• False Detection Timer: (M\/T) The PIR scans for movement and shuts lights off after 31 minutes preventing false triggers from HVAC systems\u003cbr data-mce-fragment=\"1\"\u003eOutput short circuit protection\u003cbr data-mce-fragment=\"1\"\u003e• Industry-exclusive self-configuring local manual switch input: Momentary or maintained switches are supported\u003cbr data-mce-fragment=\"1\"\u003e• Presentation Mode feature for slide or film presentations allows push buttons to turn lights OFF and keep them OFF while the room is occupied\u003cbr data-mce-fragment=\"1\"\u003e• Adjustable Time Delay: 30s, 5min, 10min, 20min, 30min\u003cbr data-mce-fragment=\"1\"\u003e• Test Mode for simplified commissioning\u003cbr data-mce-fragment=\"1\"\u003e• Manual Switch and Emergency Override are Class 1 and Class 2 circuits. Class 2 circuits provided for flexibility\u003cbr data-mce-fragment=\"1\"\u003e• Industry-exclusive •€œfail-safe•€� circuitry: In the event of product failure, Return-to-Closed feature causes the relay to default ON which eliminates life safety concerns\u003cbr data-mce-fragment=\"1\"\u003e• Industry-exclusive H.I.S. (High Inrush Stability) technology designed to handle today•€s high inrush electronic ballast loads and offer unmatched durability and service\u003cbr data-mce-fragment=\"1\"\u003e• Robust and reliable mechanically held 10A latching relay provides dependability and robust performance for all load types and provides energy savings over electronically held relays\u003cbr\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h4\u003e","brand":"Leviton","offers":[{"title":"Default Title","offer_id":44402333941914,"sku":"ODC04-IDW","price":145.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/B19_91c0a338-c278-49da-8d5a-e9b1d87ed671.jpg?v=1762990101","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/120-277v-occupancy-sensor-with-integrated-photocell-mid-range-included-white-odc04-idw","provider":"NassauNationalCable","version":"1.0","type":"link"}