{"product_id":"115-23-3367-250-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3367 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3367 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3367 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 250 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 4\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 127.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.01\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.07\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.33\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 33.8\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 1460\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 365\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 345\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 495\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3367\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842771316890,"sku":"115-23-3367","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_a4c6bbf0-5eb8-435d-abc7-25a4d35f2dfc.png?v=1759828116","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/115-23-3367-250-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}