{"product_id":"1000-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1000 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1000 MCM 3C Copper MV-90 Cable, 1000 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 1000 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 1000MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 2\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.13\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 11905\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058488668529,"sku":"NNC1000MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_396ab66e-9638-46d1-ab3f-11831bf052f8.png?v=1763020117","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/1000-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","provider":"NassauNationalCable","version":"1.0","type":"link"}