{"product_id":"1000-6-3c-mv-105-power-cable-w-ground-5kv-8kv-epr-pvc-insulation-copper-tape-shield-133-100-insulation-level","title":"1000' 6-3C MV-105 Power Cable w\/ Ground, 5kV\/8kV, EPR\/PVC Insulation, Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3C_MV105_NNC.pdf?v=1741678964\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e6-3C MV-105 Power Cable w\/ Ground, 5kV\/8kV, EPR\/PVC Insulation, Copper Tape Shield, 133%\/100% Insulation Level\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e5\/8kV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be used in wet or dry locations when installed in accordance with NEC as well as cable trays, duct, open air and direct burial installations. The cable has excellent heat, moisture and sunlight resistance. The cable meets the cold bend test at -35°C and is approved for temperatures up to 105°C wet or dry.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e6 awg medium voltage power cables, \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e6 \u003c\/span\u003emv power cable, \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e6 \u003c\/span\u003emv105 cable, \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e6 \u003c\/span\u003emv105, \u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e6 awg \u003c\/span\u003e\u003cspan\u003emv power cable, \u003c\/span\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e6 awg \u003c\/span\u003e\u003cspan\u003emv105 cable, \u003c\/span\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e6 awg \u003c\/span\u003e\u003cspan\u003emv105\u003c\/span\u003e.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommon Applications of this cable:\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cb\u003eCommercial and Industrial Settings\u003c\/b\u003e: Used to distribute electrical power within large  commercial and industrial plants.\u003cbr\u003e\u003cb\u003eRefinery and Petrochemical Plants\u003c\/b\u003e: Essential for power supply and distribution in these high-demand environments.\u003cbr\u003e\u003cb\u003eUtility Power Generation and Substations\u003c\/b\u003e: It plays a role in transferring electricity within power plants and substations.\u003cbr\u003e\u003cb\u003eWet or Dry Locations\u003c\/b\u003e: The cable is suitable for installation in both dry and we environments, provided it's installed according to NEC standards.\u003cbr\u003e\u003cb\u003eUnderground and Direct Burial Installations\u003c\/b\u003e: The cable is designed for use in direct burial installations, such as underground ducts or trenches.\u003cbr\u003e\u003cb\u003eCable Trays and Ducts\u003c\/b\u003e: It can be installed in open air, cable trays, and ducts, making it versatile for various building and construction requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B annealed compact bare copper per ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors Shield:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25% color ribbons in each phase for identification for sizes 2 AWG and above (standard: black-red-blue).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround Conductor:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUninsulated bare stranded copper conductor may be in contact with metallic shielding tape.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThree phase identified shielded conductors cabled with fillers and grounding conductor (as specified), forming a firm and cylindrical cable core. A binder tape is applied over the core.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket applied over the assembly.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072 Listed sunlight resistant, direct burial and for CT use\u003cbr\u003e• UL 1685 Flame Test (70,000 BTU\/hr)\u003cbr\u003e• UL Listed as Type MV-105 for use in accordance with NEC\u003cbr\u003e• ICEA S-93-639\/NEMA WC74\u003cbr\u003e• ICEA S-97-682\u003cbr\u003e• AEIC CS8\u003cbr\u003e• EPA 40 CFR, Part 261\u003cbr\u003e• OSHA Compliant\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eAWG Size\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 6\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConductor Diameter inches: \u003c\/b\u003e0.17\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInsulation Diameter inches: \u003c\/b\u003e0.450\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Wire AWG: \u003c\/strong\u003e6\u003cb\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Thickness inches: \u003c\/strong\u003e0.080\u003cb\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter inches: \u003c\/strong\u003e1.29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight lbs\/kft: \u003c\/strong\u003e939\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpacity 105°CinAir* amps: \u003c\/strong\u003e92\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpacity 105°Cin Duct** amps: \u003c\/strong\u003e95\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpacity 105°Cin Tray*** amps: \u003c\/strong\u003e105\u003cb\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW21300603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eMVE20603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003e6-035KVSEPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62384722182513,"sku":"NNC5250XC","price":14600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product32_ea7bf076-7e7f-4325-a139-45740730eaf1.png?v=1762459840","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/1000-6-3c-mv-105-power-cable-w-ground-5kv-8kv-epr-pvc-insulation-copper-tape-shield-133-100-insulation-level","provider":"NassauNationalCable","version":"1.0","type":"link"}