{"product_id":"10-awg-15c-copper-fr-xlpe-thermoset-cpe-jacket-control-cable-600v","title":"10 AWG 15C Copper FR-XLPE Thermoset CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85009_1_1.pdf?v=1754303112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 15C Copper FR-XLPE Thermoset CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 15C Multi-Conductor Copper Control Cable, 10 AWG 15C 600V, FR-XLPE Insulation, CPE Jacket,10 AWG 15C Flame-Retardant XLPE CPE Jacketed Control Cable, 10 AWG 15C 600V,Thermoset Insulated Multi-Conductor Control Cable,10 AWG 15C 600V FR-XLPE\/CPE Industrial Control Cable,10 AWG 15C Multi-Conductor XLPE Insulated CPE Jacket Cable, Copper Control Cable with FR-XLPE and CPE Jacket, 10 AWG 15C 600 Volt, 600V Thermoset XLPE\/CPE Jacketed Copper Cable,10 AWG 15C Multi-Conductor 600V XLPE\/CPE Copper Control Wire\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003eFlame Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003eThermoset Chlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.111\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  0.964\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft): \u003c\/strong\u003e486\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e777\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 3.9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C (Amp): \u003c\/strong\u003e20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699630489969,"sku":"NNC1015","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-08-04T140330.127.png?v=1754302855","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/10-awg-15c-copper-fr-xlpe-thermoset-cpe-jacket-control-cable-600v","provider":"NassauNationalCable","version":"1.0","type":"link"}