{"product_id":"1-inch-inverted-bucket-steam-trap-npt-ib1044-14-n-125","title":"1 Inch Inverted Bucket Steam Trap NPT IB1044-14-N-125","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IB_Series_SteamTrap.pdf?v=1743571129\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 78.2847%; height: 127.563px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003eBucket Steam Trap \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e1\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan data-sheets-root=\"1\"\u003eNPT\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eCover\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eCast Iron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eValve\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e420 SS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eInternals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan data-sheets-root=\"1\"\u003eStainless Steel\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 10px;\"\u003e\u003cstrong\u003ePart No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 10px;\"\u003eIB1044-14-N-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cbr\u003eAbout:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IB Series inverted bucket steam traps are primarily used in drip applications to effectively remove condensate from steam mains and supply lines. Their design features a discharge orifice mounted at the top of the trap body, which helps reduce the risk of failure due to dirt and debris—an advantage over many other trap types. However, inverted bucket traps have poor air-handling capabilities, making them less suitable for applications where rapid air removal is essential. As a result, they are best suited for process applications like unit heaters and laundry equipment, where discharging air during system start-up is not critical. For systems that require quick and efficient air removal, Float and Thermostatic (F\u0026amp;T) traps are the preferred option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard Inverted Bucket Steam Traps, High-Pressure Inverted Bucket Steam Traps, Thermic-Syphon Inverted Bucket Steam Traps, Heavy-Duty Inverted Bucket Steam Traps, Small-Capacity Inverted Bucket Steam Traps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Waterhammer resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e•  All stainless steel internals with hardened valve \u0026amp; seat\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• In-line repairability is simplified by having all internals attached to the cover\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e•  Suitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e•  Valve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":52222273847665,"sku":"IB1044-14-N-125","price":828.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Driver_20_c3ffd10d-7cd2-43e6-9001-895de76c5a2d.jpg?v=1763023785","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/1-inch-inverted-bucket-steam-trap-npt-ib1044-14-n-125","provider":"NassauNationalCable","version":"1.0","type":"link"}