{"product_id":"1-3c-18-9c-4-awg-ground-type-tc-tc-er-jp-generator-cable-black-600v-130-amps-28kw","title":"1\/3C + 18\/9C 4 AWG Ground Type TC\/TC-ER-JP Generator Cable Black 600V (130 amps, 28kW)","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Generator_Cable_4V.pdf?v=1761892917\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e1\/3C + 18\/9C 4 AWG Ground Type TC\/TC-ER-JP Generator Cable Black 600V\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eMulti-conductor all in one cable for connecting a 26kW generator to a transfer switch. JP (Joist Pull) rated per NEC 336.10(9). UL listed as Type TC-ER-JP for applications not to exceed 600V\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003eGenerator Cable, Type TC\/TC-ER-JP, Multi-Conductor Generator Cable, PVC Generator Cable, Type TC Cable, Type TC-ER Wire, Generator Wire, joist Pull Generator Cable, Copper Generator Cable, W\/G Generator Cable, Generator Cable, 1\/3C + 18\/9C 4 W\/G Cable, Black Generator Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Element 1: Annealed bare copper Class C\u003cbr\u003e• Element 2: Annealed bare copper Class K\u003cbr\u003e• Element 3: Annealed bare copper Class C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Element 1, 2 \u0026amp; 3: Polyvinylchloride (PVC) \u0026amp; Nylon\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e•  Black sunlight \u0026amp; flame resistant and direct burial approved PVC with ripcord rated 90°C wet or dry per UL 1277\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll 3 Elements or Conductors are cabled together with Non-Hygroscopic Polypropylene fillers as required for a circular cross-section with a clear mylar binder tape and jacketed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Element 1: Black, Red, White\u003cbr\u003e• Element 2: Black, Red, Yellow, Yellow\/Black, Blue, White, White\/Blue, Purple, Purple\/Black\u003cbr\u003e• Element 3: Green Ground\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e• UL Listed as TC-ER-JP per UL Standard 1277\u003cbr\u003e• Rated 90°C wet or dry to meet UL 83 for THHN\/THWN\u003cbr\u003e• Meets cold bend test at -40°C\u003cbr\u003e• ICEA S-73-532. ICEA S-95-658, where applicable\u003cbr\u003e• Meets UL 1581 \u0026amp; 1202 (FT-4) 70,000 BTU\/HR \u0026amp; ICEAT-29-520 210,000 BTU\/HR requirements\u003cbr\u003e• REACH compliant per Regulation (EC) No 1907\/2006 (235) Updated June 14, 2023\u003cbr\u003e• Cable is suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• Element 1 \u0026amp; 2 conductors pass UL VW-1 flame test, rated THWN\/VW-1\u003cbr\u003e• ASTM B3, B8, B174, B787\u003cbr\u003e• UL approved for Direct Burial \u0026amp; Sunlight Resistant Applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSize:\u003c\/strong\u003e 1 AWG (3 Conductors), 18 AWG (9 Conductors)\u003cstrong\u003e\u003cbr\u003eGround Wire Size:\u003c\/strong\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePolyvinylchloride (PVC) \u0026amp; Nylon\u003cbr\u003e\u003cstrong\u003eJacket Thickness: \u003c\/strong\u003e0.080 inches\u003cbr\u003e\u003cstrong\u003eJacket Color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003eOutside Diameter:\u003c\/strong\u003e 1.177 inches\u003cstrong\u003e\u003cbr\u003eAllowable Ampacity:\u003c\/strong\u003e 130 Amps \u003cbr\u003e\u003cstrong\u003eWeight: \u003c\/strong\u003e1374\/kft\u003cbr\u003e\u003cstrong\u003eRating: \u003c\/strong\u003e28kW\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003ePriority Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan\u003e1-03TCG\/18-09-VN\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAll values are nominal and subject to correction.\u003cbr\u003e*Ampacity according to NEC 310.15(B)(16) @30°C THWN 75°C insulated wires.\u003cbr\u003e**Installations shall follow NEC, applicable correcting factors shall be considered when conditions vary.\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64429556629873,"sku":"NNC20015X3K","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/download_31197cb8-a0e5-4e16-b18a-a1d2c4cf0656.jpg?v=1762991725","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/1-3c-18-9c-4-awg-ground-type-tc-tc-er-jp-generator-cable-black-600v-130-amps-28kw","provider":"NassauNationalCable","version":"1.0","type":"link"}