{"product_id":"1-1-4-inch-inverted-bucket-steam-trap-npt-ib1038s-15-n-250","title":"1 1\/4 Inch Inverted Bucket Steam Trap NPT IB1038S-15-N-250","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IB_Series_SteamTrap.pdf?v=1743571129\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 78.2847%; height: 142.891px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 32.1875px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 32.1875px;\"\u003eBucket Steam Trap \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e1 1\/4 \"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan data-sheets-root=\"1\"\u003eNPT\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.7344px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.7344px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eCover\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.7344px;\"\u003e\u003cspan\u003eCast Iron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eValve\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e420 SS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cstrong class=\"font-bold font-titillium-web\"\u003e\u003cspan\u003eInternals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan data-sheets-root=\"1\"\u003eStainless Steel\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 12.5938px;\"\u003e\n\u003ctd style=\"width: 49.8818%; text-align: center; height: 12.5938px;\"\u003e\u003cstrong\u003ePart No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.6454%; text-align: center; height: 12.5938px;\"\u003eIB1038S-15-N-250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cbr\u003eAbout:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIB Series inverted bucket steam traps are commonly used in drip applications to remove condensate from steam mains and supply lines. The discharge orifice is located at the top of the trap body, making these traps more resistant to failure from dirt and debris compared to other types. Due to their limited air-handling capability, they are suitable for process applications—such as unit heaters and laundry equipment—where rapid air discharge during system start-up is not essential. For systems that require efficient air venting, Float and Thermostatic (F\u0026amp;T) traps are the preferred choice.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard Inverted Bucket Steam Traps, High-Pressure Inverted Bucket Steam Traps, Thermic-Syphon Inverted Bucket Steam Traps, Heavy-Duty Inverted Bucket Steam Traps, Small-Capacity Inverted Bucket Steam Traps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Waterhammer resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• All stainless steel internals with hardened valve \u0026amp; seat\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• In-line repairability is simplified by having all internals attached to the cover\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Suitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Valve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":52222311170417,"sku":"IB1038S-15-N-250","price":1070.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Driver_21_73ec76c6-d391-4cd0-9be0-5962037a3f97.jpg?v=1763023790","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/1-1-4-inch-inverted-bucket-steam-trap-npt-ib1038s-15-n-250","provider":"NassauNationalCable","version":"1.0","type":"link"}