{"product_id":"1-0-awg-hvteck-aluminum-140-mil-trxlpe-ts-aia-8kv-133-il-orange-pvc-jacket-csa","title":"1\/0 AWG HVTECK Aluminum 140 mil TRXLPE TS AIA 8kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/aa_1.pdf?v=1756183768\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG HVTECK Aluminum 140 mil TRXLPE TS AIA 8kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"277\" data-start=\"246\"\u003e1\/0 AWG HVTECK 8kV Aluminum Cable 1\/C 8kV TRXLPE AIA Cable 1\/0 AWG HVTECK 133% Insulation Cable Aluminum Armored Power Cable (8kV) CSA 1\/0 AWG HVTECK Medium Voltage Cable Orange Jacket 8kV CSA Cable 8kV CSA Armored Aluminum Cable\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e140 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Jacket:\u003cbr\u003e\u003c\/strong\u003ePVC inner jacket\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmour:\u003c\/strong\u003e\u003cbr\u003eAluminum Interlocked Armour (AIA)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eOrange Polyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e• ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize: \u003c\/strong\u003e1\/0 AWG\u003cbr\u003e• \u003cstrong\u003eNumber of Strands: \u003c\/strong\u003e19\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch):\u003c\/strong\u003e  0.336 \u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation (inch):\u003c\/strong\u003e 0.654\u003cbr\u003e\u003cstrong\u003e• Insul Thickness: \u003c\/strong\u003e 140\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e  0.714\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil)\u003c\/strong\u003e:  80\u003cbr\u003e• \u003cstrong\u003eDia. Over Armour:  \u003c\/strong\u003e1.116\u003cbr\u003e•\u003cstrong\u003e Overall Jacket Thickness: \u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e  1.216  \u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e667\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e 0.168\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft: \u003c\/strong\u003e  0.211\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Air 90°C: \u003c\/strong\u003e 222\u003cbr\u003e•\u003cstrong\u003e Allowable Ampacity Directly Buried 90°C: \u003c\/strong\u003e223\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55755274846577,"sku":"NNC696825","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_e35545e4-f084-43de-afd2-ccde8692d0cf.png?v=1756191005","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/1-0-awg-hvteck-aluminum-140-mil-trxlpe-ts-aia-8kv-133-il-orange-pvc-jacket-csa","provider":"NassauNationalCable","version":"1.0","type":"link"}