{"title":"Type MV-105 Three Conductor Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":null,"products":[{"product_id":"type-mv-105-three-conductor-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"Type MV-105 Three Conductor Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eType MV-105 Three Conductor Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e25kV ARMOR-X cable, 25kV armored cable, 25kV MV cable, 25kV medium voltage cable 25kV shielded power cable, 25kV 3\/C copper cable, 25kV CU armored cable, 25kV CU MV cable, 25kV NL-EPR cable,  25kV EPR insulated cable,  25kV 133% insulation cable, 25kV tape shielded cable, 25kV copper tape shield cable, 25kV corrugated armor cable, 25kV continuous corrugated welded armor cable, ARMOR-X cable, MV-105 cable, MV-105 armored cable, MV-105 3\/C cable, MC-HL cable, 25kV tray-rated cable, 25kV direct burial cable,  25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67586660499825,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"1-awg-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"1 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG 3C 25kV ARMOR-X cable, 1 AWG 3C25kV armored cable, 1 AWG 3C25kV MV cable, 1 AWG 3C 25kV medium voltage cable ,1 AWG 3C 25kV shielded power cable, 1 AWG 3C 25kV 3\/C copper cable, 1 AWG 3C 25kV CU armored cable,1 AWG 3C 25kV CU MV cable,1 AWG 3C  25kV NL-EPR cable,1 AWG 3C 25kV EPR insulated cable, 1 AWG 3C 25kV 133% insulation cable,1-3C 25kV tape shielded cable,1-3C 25kV copper tape shield cable,1-3C 25kV corrugated armor cable, 1-3C 25kV continuous corrugated welded armor cable,1-3C ARMOR-X cable, 1-3C MV-105 cable,1-3C MV-105 armored cable,1-3C MV-105 3\/C cable,1-3C MC-HL cable,1-3C 25kV tray-rated cable, 1-3C 25kV direct burial cable,1-3C  25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e: 1AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.322 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e  1.000 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e  1.060 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e  1x4 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 2.880 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox. OD:\u003c\/strong\u003e    3.030inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e  974\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft):\u003c\/strong\u003e  3712\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb): \u003c\/strong\u003e2008\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e 21.2 inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67587353706865,"sku":"NNC5984","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"1-0-awg-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"1\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 3C 25kV ARMOR-X cable, 1\/0 AWG 3C 25kV armored cable, 1\/0 AWG 3C 25kV MV cable,1\/0 AWG 3C 25kV medium voltage cable ,1\/0 AWG 3C 25kV shielded power cable, 1\/0 AWG 3C 25kV 3\/C copper cable, 1\/0 AWG 3C 25kV CU armored cable,1\/0 AWG 3C 25kV CU MV cable,1\/0 AWG 3C 25kV NL-EPR cable,1\/0 AWG 3C 25kV EPR insulated cable,1\/0 AWG 3C 25kV 133% insulation cable,1\/0-3C 25kV tape shielded cable,1\/0-3C 25kV copper tape shield cable1\/0-3C 25kV corrugated armor cable,1\/0-3C 25kV continuous corrugated welded armor cable,1\/0-3C ARMOR-X cable,1\/0-3C MV-105 cable,1\/0-3C MV-105 armored cable,1\/0-3C MV-105 3\/C cable,1\/0-3C MC-HL cable,1\/0-3C 25kV tray-rated cable,1\/0-3C 25kV direct burial cable1\/0-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e: 1\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.361 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e 1.039 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.099 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e1x4 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 2.880 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox. OD:\u003c\/strong\u003e 3.030 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 1181\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft):\u003c\/strong\u003e 4009\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb): \u003c\/strong\u003e2534\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e  21.2 inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67587591831921,"sku":"NNC9995","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"2-0-awg-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"2\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 3C 25kV ARMOR-X cable, 2\/0 AWG 3C 25kV armored cable,2\/0 AWG 3C 25kV MV cable, 2\/0 AWG 3C 25kV medium voltage cable , 2\/0 AWG 3C 25kV shielded power cable, 2\/0 AWG 3C 25kV 3\/C copper cable, 2\/0 AWG 3C 25kV CU armored cable,2\/0 AWG 3C 25kV CU MV cable,2\/0 AWG 3C 25kV NL-EPR cable,2\/0 AWG 3C 25kV EPR insulated cable,2\/0 AWG 3C 25kV 133% insulation cable,2\/0-3C 25kV tape shielded cable,2\/0-3C 25kV copper tape shield cable,2\/0-3C 25kV corrugated armor cable,2\/0-3C 25kV continuous corrugated welded armor cable,2\/0-3C ARMOR-X cable,2\/0-3C MV-105 cable, 2\/0-3C MV-105 armored cable,2\/0-3C MV-105 3\/C cable ,2\/0-3C MC-HL cable, 2\/0-3C 25kV tray-rated cable, 2\/0-3C 25kV direct burial cable, 2\/0-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e:  2\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.405 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e1.084 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.144 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e1x4 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 3.000 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox. OD: \u003c\/strong\u003e3.158 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 1654\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft):\u003c\/strong\u003e 4619\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb): \u003c\/strong\u003e3194\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e 22.0 inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 324px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 203.016px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 120.984px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e649938\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67587784802673,"sku":"NNC649938","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"3-0-awg-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"3\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 3C 25kV ARMOR-X cable, 3\/0 AWG 3C 25kV armored cable, 3\/0 AWG 3C25kV MV cable, 3\/0 AWG 3C 25kV medium voltage cable , 3\/0 AWG 3C 25kV shielded power cable, 3\/0 AWG 3C 25kV 3\/C copper cable, 3\/0 AWG 3C 25kV CU armored cable,3\/0 AWG 3C 25kV CU MV cable, 3\/0 AWG 3C25kV NL-EPR cable, 3\/0 AWG 3C 25kV EPR insulated cable,3\/0 AWG 3C 25kV 133% insulation cable,3\/0-3C 25kV tape shielded cable, 3\/0-3C 25kV copper tape shield cable,3 \/0-3C25kV corrugated armor cable, 3\/0-3C25kV continuous corrugated welded armor cable,3\/0-3C ARMOR-X cable,3\/0-3C MV-105 cable, 3\/0-3C MV-105 armored cable, 3\/0-3CMV-105 3\/C cable ,3\/0-3C MC-HL cable, 3\/0-3C 25kV tray-rated cable,3\/0-3C 25kV direct burial cable, 3\/0-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e:  3\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.456 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.134\u003cstrong\u003e \u003c\/strong\u003einch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.194 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e1x3 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 3.220 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD: \u003c\/strong\u003e3.400 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 1802\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft):\u003c\/strong\u003e  5165\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb):\u003c\/strong\u003e 4027\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e  23.8 inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67588122739057,"sku":"NNC1473","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"4-0-awg-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"4\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 3C 25kV ARMOR-X cable, 4\/0 AWG 3C 25kV armored cable, 4\/0 AWG 3C 25kV MV cable, 4\/0 AWG 3C 25kV medium voltage cable , 4\/0 AWG 3C 25kV shielded power cable, 4\/0 AWG 3C 25kV 3\/C copper cable, 4\/0 AWG 3C 25kV CU armored cable, 4\/0 AWG 3C 25kV CU MV cable, 4\/0 AWG 3C 25kV NL-EPR cable, 4\/0 AWG 3C 25kV EPR insulated cable, 4\/0 AWG 3C 25kV 133% insulation cable, 4\/0-3C 25kV tape shielded cable, 4\/0-3C 25kV copper tape shield cable, 4\/0-3C 25kV corrugated armor cable, 4\/0-3C 25kV continuous corrugated welded armor cable, 4\/0-3C ARMOR-X cable, 4\/0-3C MV-105 cable, 4\/0-3C MV-105 armored cable, 4\/0-3CMV-105 3\/C cable , 4\/0-3C MC-HL cable, 4\/0-3C 25kV tray-rated cable, 4\/0-3C 25kV direct burial cable, 4\/0-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e:  4\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.512 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.190\u003cstrong\u003e \u003c\/strong\u003einch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.250 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e1x3 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 3.220 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD: \u003c\/strong\u003e3.400 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 2214\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft):\u003c\/strong\u003e 5712\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb):\u003c\/strong\u003e 5078\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e 23.8inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67588464116081,"sku":"NNC9632","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"250-mcm-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"250 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM 3C 25kV ARMOR-X cable, 250 MCM 3C 25kV armored cable, 250 MCM 3C 25kV MV cable, 250 MCM 3C 25kV medium voltage cable ,250 MCM 3C 25kV shielded power cable, 250 MCM 3C 25kV 3\/C copper cable, 250 MCM 3C 25kV CU armored cable, 250 MCM 3C 25kV CU MV cable, 250 MCM 3C 25kV NL-EPR cable, 250 MCM 3C 25kV EPR insulated cable, 250 MCM 3C 25kV 133% insulation cable, 250-3C 25kV tape shielded cable, 250-3C 25kV copper tape shield cable, 250-3C 25kV corrugated armor cable, 250-3C 25kV continuous corrugated welded armor cable, 250-3C ARMOR-X cable, 250-3C MV-105 cable, 250-3C MV-105 armored cable, 250-3C MV-105 3\/C cable ,250-3C MC-HL cable, 250-3C 25kV tray-rated cable,250-3C 25kV direct burial cable,250-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e: 250 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e  37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.558 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.244\u003cstrong\u003e \u003c\/strong\u003einch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.304 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e1x3AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 3.540 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD: \u003c\/strong\u003e3.720 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 2577\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft):\u003c\/strong\u003e 6366\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb):\u003c\/strong\u003e 6000\u003cbr\u003e\u003cstrong\u003eMin Bending Radius: \u003c\/strong\u003e26.0inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67593572548977,"sku":"NNC4582","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"350-mcm-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"350 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM 3C 25kV ARMOR-X cable, 350 MCM 3C 25kV armored cable, 350 MCM 3C 25kV MV cable, 350 MCM 3C 25kV medium voltage cable ,350 MCM 3C 25kV shielded power cable, 350 MCM 3C 25kV 3\/C copper cable, 350 MCM 3C  25kV CU armored cable, 350 MCM 3C 25kV CU MV cable, 350 MCM 3C 25kV NL-EPR cable, 350 MCM 3C 25kV EPR insulated cable, 350 MCM 3C 25kV 133% insulation cable, 350-3C 25kV tape shielded cable,350-3C 25kV copper tape shield cable, 350-3C 25kV corrugated armor cable, 350-3C 25kV continuous corrugated welded armor cable, 350-3C ARMOR-X cable, 350-3C MV-105 cable,350-3C MV-105 armored cable, 350-3C MV-105 3\/C cable, 350-3C MC-HL cable, 350-3C 25kV tray-rated cable, 350-3C 25kV direct burial cable, 350-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e: 350 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e  37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.661 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.347\u003cstrong\u003e \u003c\/strong\u003einch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.407 inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e1x2AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 3.540 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD: \u003c\/strong\u003e3.720inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 3561 \u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft): \u003c\/strong\u003e7608\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb): \u003c\/strong\u003e8400\u003cbr\u003e\u003cstrong\u003eMin Bending Radius: \u003c\/strong\u003e26.0inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67593788883313,"sku":"NNC1236","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"500-mcm-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"500 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM 3C 25kV ARMOR-X cable, 500 MCM 3C 25kV armored cable, 500 MCM 3C 25kV MV cable, 500 MCM 3C 25kV medium voltage cable , 500 MCM 3C 25kV shielded power cable,500 MCM 3C 25kV 3\/C copper cable, 500 MCM 3C 25kV CU armored cable, 500 MCM 3C 25kV CU MV cable, 500 MCM 3C 25kV NL-EPR cable, 500 MCM 3C 25kV EPR insulated cable,500 MCM 3C 25kV 133% insulation cable, 500-3C 25kV tape shielded cable, 500-3C 25kV copper tape shield cable, 500-3C 25kV corrugated armor cable, 500-3C 25kV continuous corrugated welded armor cable, 500-3C ARMOR-X cable, 500-3C MV-105 cable, 500-3C MV-105 armored cable, 500-3C MV-105 3\/C cable, 500-3C MC-HL cable, 350-3C 25kV tray-rated cable, 500-3C 25kV direct burial cable, 500-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e: 500 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.766inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e1.452inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.512inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e 1x1AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e  3.850inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD: \u003c\/strong\u003e4.028inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 5023 \u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft): \u003c\/strong\u003e9435\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb): \u003c\/strong\u003e12000\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e 28.2inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e664985\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67594015998321,"sku":"NNC664985","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"},{"product_id":"750-mcm-3c-type-mv-105-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"750 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC466543.pdf?v=1790584835\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Type MV-105 Copper 25kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 25KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso known as:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM 3C 25kV ARMOR-X cable, 750 MCM 3C 25kV armored cable, 750 MCM 3C 25kV MV cable, 750 MCM 3C 25kV medium voltage cable, 750 MCM 3C 25kV shielded power cable, 750 MCM 3C 25kV 3\/C copper cable, 750 MCM 3C 25kV CU armored cable,750 MCM 3C 25kV CU MV cable, 750 MCM 3C 25kV NL-EPR cable, 750 MCM 3C 25kV EPR insulated cable, 750 MCM 3C  25kV 133% insulation cable, 750-3C 25kV tape shielded cable, 750-3C 25kV copper tape shield cable, 750-3C 25kV corrugated armor cable, 750-3C 25kV continuous corrugated welded armor cable, 750-3C ARMOR-X cable, 750-3C MV-105 cable, 750-3C MV-105 armored cable,750-3C MV-105 3\/C cable, 750-3C MC-HL cable, 750-3C 25kV tray-rated cable, 750-3C 25kV direct burial cable, 750-3C 25kV sunlight-resistant cable.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstruction: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eper ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Wax paper filler\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e UL 1072 Medium-Voltage Power Cables\u003cbr\u003e UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements)\u003cbr\u003e Made in America: Compliant with both Buy American and Buy America Act (BAA)   requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America   requirements per 49 C.F.R. part 661\u003cbr\u003e ABS Listed as CWCMC .\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSpeciation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e: 750 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands: \u003c\/strong\u003e61\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.968inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e1.664inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.724inch\u003cbr\u003e\u003cstrong\u003eGround: \u003c\/strong\u003e  1x1\/0AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e  3.850inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD:\u003c\/strong\u003e 4.030inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft):\u003c\/strong\u003e 7439 \u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft): \u003c\/strong\u003e12478\u003cstrong\u003e \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb): \u003c\/strong\u003e18000\u003cbr\u003e\u003cstrong\u003eMin Bending Radius:\u003c\/strong\u003e 28.2inch\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67594135667057,"sku":"NNC4528","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1024x1024_2x_75b96ec1-8039-454a-8c1f-168b67762e93.webp?v=1790584066"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/type-mv-105-three-conductor-copper-25kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}