{"title":"Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eType MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"14-awg-2c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 2C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e14 AWG 2C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 2C Armor Welded Armor MC Cable 14 AWG 2C MC-HL (Heat and Light Resistant) Cable 14 AWG 2C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 2C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 2\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.480\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil): \u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e  0.586\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:  \u003c\/strong\u003e38\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e159\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft: \u003c\/strong\u003e3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp): \u003c\/strong\u003e25\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e568912\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55742318641521,"sku":"NNC568912^","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-4c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e14 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso known as:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e14 AWG 4C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 4C Armor Welded Armor MC Cable 14 AWG 4C MC-HL (Heat and Light Resistant) Cable 14 AWG 4C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 4C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 4\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.650\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil): \u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.676\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:  \u003c\/strong\u003e64\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e214\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft: \u003c\/strong\u003e3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp): \u003c\/strong\u003e20\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e589289\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55742417207665,"sku":"NNC589289^","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-6c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 6C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 6C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e14 AWG 6C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 6C Armor Welded Armor MC Cable 14 AWG 6C MC-HL (Heat and Light Resistant) Cable 14 AWG 6C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 6C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 6\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.650\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil): \u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.756\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e 89\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e267\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft: \u003c\/strong\u003e3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp): \u003c\/strong\u003e20\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550607\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55742493098353,"sku":"NNC550607","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-7c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 7C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso known as:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e14 AWG 7C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 7C Armor Welded Armor MC Cable 14 AWG 7C MC-HL (Heat and Light Resistant) Cable 14 AWG 7C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 7C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.650\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil): \u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.756\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e 89\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e248\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft: \u003c\/strong\u003e3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp): \u003c\/strong\u003e20\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e586450\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55743963431281,"sku":"NNC586450","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-7c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 7C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 7C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e12 AWG 7C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 7C Armor Welded Armor MC Cable 12 AWG 7C MC-HL (Heat and Light Resistant) Cable 12 AWG 7C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 7C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.700\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.806\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e 142\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e337\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp): \u003c\/strong\u003e24\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e890592\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55743969624433,"sku":"NNC890592","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-8c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 8C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 8C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e14 AWG 8C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 8C Armor Welded Armor MC Cable 14 AWG 8C MC-HL (Heat and Light Resistant) Cable 14 AWG 8C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 8C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 8\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.700\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.806\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e  114\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):   \u003c\/strong\u003e318 \u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 17\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550609\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55743972966769,"sku":"NNC550609","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-9c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 9C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 9C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e14 AWG 9C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 9C Armor Welded Armor MC Cable 14 AWG 9C MC-HL (Heat and Light Resistant) Cable 14 AWG 9C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 9C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 9\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.700\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.896\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e   127\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e 352\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 17\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e890611!\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55743984566641,"sku":"NNC890611!","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-11c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 11C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 11C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e14 AWG 11C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 11C Armor Welded Armor MC Cable 14 AWG 11C MC-HL (Heat and Light Resistant) Cable 14 AWG 11C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 11C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 11\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.480\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.896\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e    153\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e  388\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 12\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550614\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55743991480689,"sku":"NNC550614","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-12c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 12C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e14 AWG 12C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 12C Armor Welded Armor MC Cable 14 AWG 12C MC-HL (Heat and Light Resistant) Cable 14 AWG 12C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 12C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 12\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:0.790\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.896\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e    153\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e   387\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 12\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e890585!\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744031785329,"sku":"NNC890585!","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-18c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 18C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 18C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e14 AWG 18C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 18C Armor Welded Armor MC Cable 14 AWG 18C MC-HL (Heat and Light Resistant) Cable 14 AWG 18C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 18C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 18\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:0.920\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e  1.026\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e 242\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):   \u003c\/strong\u003e540\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 12\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550615\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744036045169,"sku":"NNC550615","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"14-awg-36c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"14 AWG 36C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 36C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e14 AWG 36C Metal Clad (MC) Cable Control Cable with Corrugated Steel 14 AWG 36C Armor Welded Armor MC Cable 14 AWG 36C MC-HL (Heat and Light Resistant) Cable 14 AWG 36C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 14 AWG 36C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  14\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 36\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 14\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:0.943\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e  1.043\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e  472\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):   \u003c\/strong\u003e793\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 3.170\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 10\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550617\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744037552497,"sku":"NNC550617","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-2c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 2C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e12 AWG 2C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 2C Armor Welded Armor MC Cable 12 AWG 2C MC-HL (Heat and Light Resistant) Cable 12 AWG 2C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 2C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 2\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.530\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.636\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e  61\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):   \u003c\/strong\u003e193\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e25\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 30\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550810\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744038109553,"sku":"NNC550810","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-3c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e12 AWG 3C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 3C Armor Welded Armor MC Cable 12 AWG 3C MC-HL (Heat and Light Resistant) Cable 12 AWG 3C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 3C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 3\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.610\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   0.716\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e 81\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e236\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e25\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 30\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e568795\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744043614577,"sku":"NNC568795","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-4c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e12 AWG 4C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 4C Armor Welded Armor MC Cable 12 AWG 4C MC-HL (Heat and Light Resistant) Cable 12 AWG 4C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 4C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 4\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.650\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e  0.756\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e 102\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e  272 \u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 24\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e568796\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744051478897,"sku":"NNC568796","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-5c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 5C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 5C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e12 AWG 5C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 5C Armor Welded Armor MC Cable 12 AWG 5C MC-HL (Heat and Light Resistant) Cable 12 AWG 5C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 5C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 5\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.700\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e 0.806\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e  121\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e 313\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 24\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550610\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744063963505,"sku":"NNC550610","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-6c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 6C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 6C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e12 AWG 6C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 6C Armor Welded Armor MC Cable 12 AWG 6C MC-HL (Heat and Light Resistant) Cable 12 AWG 6C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 6C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 6\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.700\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e 0.806\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e   141\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e  336\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp): \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 24\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550611\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744075301233,"sku":"NNC550611","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-8c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 8C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 8C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e12 AWG 8C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 8C Armor Welded Armor MC Cable 12 AWG 8C MC-HL (Heat and Light Resistant) Cable 12 AWG 8C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 8C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 8\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:   0.790\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e 0.896\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e   182\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e   409\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 21\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550618\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744076874097,"sku":"NNC550618","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-11c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 11C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 11C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e12 AWG 11C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 11C Armor Welded Armor MC Cable 12 AWG 11C MC-HL (Heat and Light Resistant) Cable 12 AWG 11C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 11C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 11\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.920\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e1.026\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e   243\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e   516\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 15\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 250.225px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550619\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744079528305,"sku":"NNC550619","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-12c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 12C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e12 AWG 12C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 12C Armor Welded Armor MC Cable 12 AWG 12C MC-HL (Heat and Light Resistant) Cable 12 AWG 12C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 12C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 12\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:  0.920\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e1.026\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e  263\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e   543\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 15\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 42.125px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e584189\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744081690993,"sku":"NNC584189","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"12-awg-18c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"12 AWG 18C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 18C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e12 AWG 18C Metal Clad (MC) Cable Control Cable with Corrugated Steel 12 AWG 18C Armor Welded Armor MC Cable 12 AWG 18C MC-HL (Heat and Light Resistant) Cable 12 AWG 18C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 12 AWG 18C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  12\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 18\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 12\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 1.020\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e 1.126\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e 385\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e   722\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e 2.002\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 15\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 42.125px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550620\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744091062641,"sku":"NNC550620","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"10-awg-2c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"10 AWG 2C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 2C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e10 AWG 2C Metal Clad (MC) Cable Control Cable with Corrugated Steel 10 AWG 2C Armor Welded Armor MC Cable 10 AWG 2C MC-HL (Heat and Light Resistant) Cable 10 AWG 2C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 10 AWG 2C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  10\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 2\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 10\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.650\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e 0.756\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft:\u003c\/strong\u003e 97\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e 268\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  1.253\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 35\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 40\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 42.125px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e954321!\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744092438897,"sku":"NNC954321!","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"10-awg-5c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"10 AWG 5C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 5C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e10 AWG 5C Metal Clad (MC) Cable Control Cable with Corrugated Steel 10 AWG 5C Armor Welded Armor MC Cable 10 AWG 5C MC-HL (Heat and Light Resistant) Cable 10 AWG 5C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 10 AWG 5C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  10\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 5\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 10\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:0.790\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e 0.896\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e193\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e  411 \u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  1.253\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 42.125px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550612\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744093028721,"sku":"NNC550612","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"10-awg-6c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"10 AWG 6C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 6C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e10 AWG 6C Metal Clad (MC) Cable Control Cable with Corrugated Steel 10 AWG 6C Armor Welded Armor MC Cable 10 AWG 6C MC-HL (Heat and Light Resistant) Cable 10 AWG 6C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 10 AWG 6C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  10\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 6\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 10\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:0.790\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e 0.896\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e 225\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e   450 \u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  1.253\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 42.125px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550613\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744095158641,"sku":"NNC550613","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"10-awg-8c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"10 AWG 8C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 8C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003e10 AWG 8C Metal Clad (MC) Cable Control Cable with Corrugated Steel 10 AWG 8C Armor Welded Armor MC Cable 10 AWG 8C MC-HL (Heat and Light Resistant) Cable 10 AWG 8C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 10 AWG 8C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  10\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 8\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 10\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e: 0.920\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e  1.026\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e  289\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e  564 \u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  1.253\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 28\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 326.4px; height: 42.125px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550622\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744095355249,"sku":"NNC550622","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"},{"product_id":"10-awg-11c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v","title":"10 AWG 11C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45227_1.pdf?v=1755588134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 11C Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire's 600 Volt Type MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -40°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e10 AWG 11C Metal Clad (MC) Cable Control Cable with Corrugated Steel 10 AWG 11C Armor Welded Armor MC Cable 10 AWG 11C MC-HL (Heat and Light Resistant) Cable 10 AWG 11C XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable 10 AWG 11C MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003eCross Linked Polyethylene (XLPE) XHHW-2\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded copper with green insulation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003ePolypropylene filler as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolyester flat thread binder tape as needed\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Aluminum Welded Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize\u003c\/strong\u003e:  10\u003cbr\u003e•\u003cstrong\u003e Number of Conductor\u003c\/strong\u003e: 11\u003cbr\u003e• \u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 7\u003cbr\u003e• \u003cstrong\u003eInsulation Thickness (Mil)\u003c\/strong\u003e: 30\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:\u003c\/strong\u003e 1 x 10\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor(inch)\u003c\/strong\u003e:1.020\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e50 \u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e 1.126\u003cbr\u003e•\u003cstrong\u003e Copper Weight lb\/1000ft: \u003c\/strong\u003e  386\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e  699\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  1.253\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 20\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd style=\"width: 326.4px; height: 42.125px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 250.225px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.175px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550623\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744099778929,"sku":"NNC550623","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3c18029c-9e8a-470d-846f-18be1b512fab.png?v=1755590900"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-control-cable-600v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}