{"title":"Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"","products":[{"product_id":"14-awg-3c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"14 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 3C MC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, 14 AWG 3C XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, 14 AWG 3C VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 3 x 18\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.530\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  0.630\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 51\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  219 \u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  4.4\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  3.170\u003cbr\u003e\u003cstrong\u003e• Inductive Resistance Ω\/1000ft: \u003c\/strong\u003e0.058\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 25\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744142836081,"sku":"NNC1432","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_a078db64-8617-4ec4-8106-0b98d2dd9460.png?v=1755674668"},{"product_id":"14-awg-4c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"14 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 4C MC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, 14 AWG 4C XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, 14 AWG 4C VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 3 x 18\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.569\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e   0.669\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 64\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  240\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  4.7\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e2.631\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  3.170\u003cbr\u003e\u003cstrong\u003e• Inductive Resistance Ω\/1000ft: \u003c\/strong\u003e0.058\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744145686897,"sku":"NNC1433","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_a078db64-8617-4ec4-8106-0b98d2dd9460.png?v=1755674668"},{"product_id":"12-awg-3c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"12 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 3C MC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, 12 AWG 3C XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, 12 AWG 3C VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 3 x 16\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.570\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  0.670\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  233\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  4.7\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  2.002\u003cbr\u003e\u003cstrong\u003e• Inductive Resistance Ω\/1000ft: \u003c\/strong\u003e0.054\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 25\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 30\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e641468\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744151912817,"sku":"NNC641468","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_a078db64-8617-4ec4-8106-0b98d2dd9460.png?v=1755674668"},{"product_id":"12-awg-4c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"12 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 4C MC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, 12 AWG 4C XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, 12 AWG 4C VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 3 x 16\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.610\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  0.710\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 101\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  291\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 5.0\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e1.662\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e  2.002\u003cbr\u003e\u003cstrong\u003e• Inductive Resistance Ω\/1000ft: \u003c\/strong\u003e0.054\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 24\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744155713905,"sku":"NNC1444","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_a078db64-8617-4ec4-8106-0b98d2dd9460.png?v=1755674668"},{"product_id":"10-awg-3c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"10 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 3C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 3C MC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, 10 AWG 3C  XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, 10 AWG 3C  VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 14\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.610\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e   0.716\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 135\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 299\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 5.0\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e   1.253\u003cbr\u003e\u003cstrong\u003e• Inductive Resistance Ω\/1000ft: \u003c\/strong\u003e0.050\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 35\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  40\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e641504\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744157450609,"sku":"NNC641504","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_a078db64-8617-4ec4-8106-0b98d2dd9460.png?v=1755674668"},{"product_id":"10-awg-4c-type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"10 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 4C MC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, 10 AWG 4C XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, 10 AWG 4C VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 14\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.700\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  0.800\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e  161\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  379\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 5.6\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°Ω \/1000ft:\u003c\/strong\u003e   1.253\u003cbr\u003e\u003cstrong\u003e• Inductive Resistance Ω\/1000ft: \u003c\/strong\u003e0.050\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  32\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744161874289,"sku":"NNC1446","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_a078db64-8617-4ec4-8106-0b98d2dd9460.png?v=1755674668"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}