{"title":"Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"","products":[{"product_id":"8-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"8 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e8 AWG 4C Type MC-HL copper power cable, 8 AWG 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 8 AWG 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.141\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1 x 10\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.790\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 0.890\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 504\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 6.2\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  422\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 40\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 44\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290824393073,"sku":"NNC08LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_769c11ce-4b20-4e22-a589-2577f7669fde.png?v=1763025880"},{"product_id":"6-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"6 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e 6 AWG 4C Type MC-HL copper power cable, 6 AWG 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 6 AWG 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.177\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.920\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  1.020\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 691\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 7.1\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  671\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 52\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 60\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290834747761,"sku":"NNC06LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_f89e5d8a-d100-43d4-b6e2-2b8b7f048f56.png?v=1763025882"},{"product_id":"4-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"4 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4 AWG 4C Type MC-HL copper power cable, 4 AWG 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 4 AWG 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.225\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 1.020\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  1.120\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  914\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 7.8\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  1068\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  68\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 76\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 53.4305%;\" height=\"35\" width=\"446\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%;\"\u003e\u003cstrong\u003e Compatiable with manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 54.1429%;\" height=\"32\" width=\"189\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.245%;\"\u003e\u003cstrong\u003e      Southwire \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2401%;\"\u003e         \u003cspan data-sheets-root=\"1\"\u003e641520\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290856440177,"sku":"NNC641520","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_0f606944-17b3-4f5e-aa99-1f578d31c78a.png?v=1763025884"},{"product_id":"2-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"2 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG 4C Type MC-HL copper power cable, 2 AWG 4C  Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 2 AWG 4C  LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.282\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1 x 6\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.220 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.320\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1358\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 9.2\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  1698\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e   92\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 104\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290862240113,"sku":"NNC02LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_22aed9c6-dade-4ad8-963c-a190d06ecd23.png?v=1763025884"},{"product_id":"1-0-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"1\/0 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 4C Type MC-HL copper power cable, 1\/0 AWG 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 1\/0 AWG 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.361\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1 x 6\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e   1.480\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.580\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 2030\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 11.1\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  2703\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 120\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 136\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290862502257,"sku":"NNC1\/0LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_c3ad5331-a1e8-4ef4-b0e0-ccb1ae7e0d90.png?v=1763025885"},{"product_id":"2-0-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"2\/0 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 4C Type MC-HL copper power cable, 2\/0 AWG 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 2\/0 AWG 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.405\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 4\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 1.540\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  1.660\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 2444\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 11.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  3407\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 156\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"446\" height=\"35\" style=\"width: 53.4305%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%;\"\u003e\u003cstrong\u003e Compatiable with manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"189\" height=\"32\" style=\"width: 54.1429%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.245%;\"\u003e\u003cstrong\u003e      Southwire \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2401%;\"\u003e        \u003cspan data-sheets-root=\"1\"\u003e572421\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290866401649,"sku":"NNC572421","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_9cef9e33-57cc-46cb-9a72-4ecbb199148e.png?v=1763025885"},{"product_id":"4-0-awg-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"4\/0 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 4C Type MC-HL copper power cable, 4\/0 AWG 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 4\/0 AWG 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.512\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 4\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.845\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  1.965\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 3541\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 13.8\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  5416\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 184\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 208\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 48.7998%; height: 75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.3221%; height: 35.5966px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 43.5083%; height: 19.6023px;\"\u003e\u003cstrong\u003eSouthwire : :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8137%; height: 19.6023px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e550856\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290900513137,"sku":"NNC550856","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_11539d32-458d-402d-8c83-a9adb18be362.png?v=1763025887"},{"product_id":"250-mcm-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"250 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM 4C Type MC-HL copper power cable, 250 MCM 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 250 MCM 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.558\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 4\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e   2.040\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  2.160\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  4253\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  15.1\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  6400\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 204 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 232\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290951696753,"sku":"NNC250LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/124_db64ecfd-f036-47af-aa6e-66f1a7746841.png?v=1763025890"},{"product_id":"350-mcm-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"350 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM 4C Type MC-HL copper power cable, 350 MCM 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 350 MCM 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.661\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1 x 3\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 2.290 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 75\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 2.440\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  5787\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 17.1\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  8960\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  248\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 280\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290965721457,"sku":"NNC350LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/124_db64ecfd-f036-47af-aa6e-66f1a7746841.png?v=1763025890"},{"product_id":"500-mcm-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"500 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM 4C Type MC-HL copper power cable, 500 MCM 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 500 MCM 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.789\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1 x 2\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  2.670\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 75\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 2.820\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 7756\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 19.7\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  12800\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  304\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 344\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"5\" width=\"446\" style=\"width: 437px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 427.727px;\"\u003e\u003cstrong\u003e                Compatiable with manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable height=\"32\" width=\"189\" style=\"width: 404px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 184.114px;\"\u003e\u003cstrong\u003e      Southwire \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 205.477px;\"\u003e         \u003cspan data-sheets-root=\"1\"\u003e563069\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290971062641,"sku":"NNC563069","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/124_db64ecfd-f036-47af-aa6e-66f1a7746841.png?v=1763025890"},{"product_id":"750-mcm-4c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"750 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45354_2_1_1.pdf?v=1755670708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 4C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM 4C Type MC-HL copper power cable, 750 MCM 4C Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 750 MCM 4C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM 8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  61\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.968\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  80\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1 x 1\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  3.220 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 3.390\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  11602\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 23.7\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  19200\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  380\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 428\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290979254641,"sku":"NNC750LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/124_db64ecfd-f036-47af-aa6e-66f1a7746841.png?v=1763025890"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}