1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2
Applications:
Tray XHHW Cable is designed for use for power distribution channels when voltage does not exceed 600 volts. It is a type of instrumentation cable which is insulated and jacketed for maximum chemical and mechanical protection. This cable has a long service life and can withstand harsh outdoor environmental conditions. The cable is printed with numbers and color-coded for easy identification.
This cable is used in raceway systems, cable trays, free air, and direct burial in:
- ā¢Ā Burglar alarms
- ⢠Cash registers
- ⢠Control systems
- ⢠Intercom wiring
- ⢠Petrochemical facilities
- ⢠Industrial control systems
The electrical cable is also suitable for NEC Class 1 Division 2 hazardous locations. XHHW tray cable is equally effective as a power and control cable. The electrical cable is flame-retardant. s and sunlight-resistant, s a recommended maximum temperature of 90°C. The minimum recommended temperature is -25°C. The electrical cable also has excellent moisture resistance.
Also Known As:
1 AWG 3C Cable Tray, 1 AWG 3C Cable Tray Types, 1 AWG 3C Electrical Cable Tray, 1 AWG 3C Pvc Cable Tray, 1 AWG 3C wire cable tray, 1 AWG 3C cable tray wire, 1 AWG 3C Tray Instrument Cable, 1 AWG 3C Tray Instrumentation Cable, 1 AWG 3CĀ TC-ER Cable, 1 AWG 3CĀ direct burial tray cable, 1 AWG 3C XLP Cable, 1 AWG 3C PVC Cable, 1 AWG 3C Exposed Run Tray Cable, 1 AWG 3C XHHW tray cable, 1 AWG 3C XHHW tray wire, 1 AWG 3C tinned copper tray cable, 1 AWG 3C flame-retardant tray cable, 1 AWG 3C tray power cable, 1 AWG 3CĀ ray control cable.
Ā
Standards:
⢠UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors.
⢠Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
⢠Individual conductors pass UL VW-1 flame test and rated XHHW-2/VW1, UL 1581/UL 2556 VW-1
⢠Rated at 90°C wet or dry
⢠Oil Res I & II
⢠āHeavy Dutyā rating per ICEA Standards
⢠Meets cold bend test at -25°C
⢠NEMA WC70/ICEA S-95-658, NEMA WC57/ICEA S-73-532
⢠IEEE 1202 and CSA FT4 70,000 BTU Flame Test
⢠IEEE 383 70,000 BTU Vertical Flame Test
⢠ICEA T-29-520 210,000 BTU
Conductor:
⢠Fully annealed bare copper per ASTM B-3, Class B stranding per ASTM B-8
Insulation:
⢠Flame retardant Cross-linked Polyethylene (FR-XLPE) that is heat and moisture resistant. Also has a VW-1 rating and is XHHW-2 per UL 44
Ground:
⢠Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8
Assembly:
⢠Conductors are cabled together with or without fillers as required to form a round compact cable core with a binder tape
Jacket:
⢠Flame and sunlight resistant black PVC rated 90°C wet or dry per UL 1277
Options:
⢠ICEA Method 1, Table E-1 Color Code
Specification:
⢠Gauge: 1 AWG
⢠No. Conductors: 3
⢠No. of Strands: 19
ā¢Ā GroundĀ Wire Size :Ā 6Ā AWG
⢠Insulation Thickness: 0.055 Inches
⢠Jacket Thickness: 0.080 Inches
⢠Overall Diameter : 1.093 Inches