{"title":"Three Conductor Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"","products":[{"product_id":"8-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"8 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e8 AWG 3C Three Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 8 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 8 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.141\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 14\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.750\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 0.850\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  444\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 6.0\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  396\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  50\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 55\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294660346225,"sku":"NNC18LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"6-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"6 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e6 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 6 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 6 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.177\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 3 x 12\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.840\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 0.940\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 589\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  6.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  629\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  65\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 75\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294667555185,"sku":"NNC16LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"4-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"4 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 4 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 4 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.225\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  0.920\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.020\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  718\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  7.1\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  1001\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e   85\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 95\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e647699\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294678139249,"sku":"NNC647699","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"2-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"2 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 2 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 2 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.282\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 6\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.020\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.120\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1045\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 7.8\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  1592\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 130\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294761337201,"sku":"NNC12LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"1-0-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"1\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 1\/0 AWG 3C  VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 1\/0 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.361\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 10\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.350\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.450\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1679\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  10.2\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e 2534\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  150\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e 170\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294769987953,"sku":"NNC1\/01LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"2-0-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"2\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 2\/0 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 2\/0 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.405\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 10\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.470\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.576\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1992\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 11.0\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e 3194\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  175\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  195\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px;\" height=\"25\" width=\"340\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 330px;\"\u003e\u003cstrong\u003eCompatiable with manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 344px; height: 28px;\" height=\"32\" width=\"444\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 198.688px; height: 22px;\"\u003e\u003cstrong\u003e      Southwire \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 129.312px; height: 22px;\"\u003e       \u003cspan data-sheets-root=\"1\"\u003e672673\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294832902513,"sku":"NNC672673","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"3-0-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"3\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 3\/0 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 3\/0 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.456\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 8\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.540\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.660\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 2427\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 11.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  4027\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e   200\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  225\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px;\" height=\"25\" width=\"340\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 330px;\"\u003e\u003cstrong\u003eCompatiable with manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 344px; height: 28px;\" height=\"32\" width=\"444\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 198.688px; height: 22px;\"\u003e\u003cstrong\u003e      Southwire \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 129.312px; height: 22px;\"\u003e     \u003cspan data-sheets-root=\"1\"\u003e586674\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55295016010097,"sku":"NNC586674","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"4-0-awg-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"4\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 4\/0 AWG 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 4\/0 AWG 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.512\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 8\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.670\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  1.790\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 2963\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 12.5\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  5078\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e   230\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  260\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55295065129329,"sku":"NNC4\/01LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"250-mcm-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"250 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 250 MCM 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 250 MCM 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.558\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 8\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.845\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e   1.965\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 3458\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 13.8\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  6000\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  255\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  290\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55295222055281,"sku":"NNC2501LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"350-mcm-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"350 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 350 MCM 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 350 MCM 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.661\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 6\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e   2.200\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e   2.320\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 4623\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 16.2\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  8400\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  310\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  350\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55295283790193,"sku":"NNC3501LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"500-mcm-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"500 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 500 MCM 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 500 MCM 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.789\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 6\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 2.430\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 75\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 2.580\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  6371\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 18.1\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  12000\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  380\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  430\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55295292899697,"sku":"NNC5001LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"},{"product_id":"750-mcm-3c-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"750 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM 3C Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, 750 MCM 3C VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, 750 MCM 3C LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e  3\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.968\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  3 x 4\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 2.880\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 75\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 3.030\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  9190\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  21.2\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  18000\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e   475\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  535\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55295297126769,"sku":"NNC7501LSZH-TP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom_bd26420c-795b-4b29-b6cb-2feb59a729bb.png?v=1763025932"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/three-conductor-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}