{"title":"Three Conductor MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"","products":[{"product_id":"8-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"8 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 64  amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 66 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e8 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 8 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 8 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.140\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.470\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.080\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.170 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 64 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 66\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 735 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896732549489,"sku":"NNC030336","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d62e028d-3980-438d-be3f-686b7288dd53.png?v=1759829687"},{"product_id":"6-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"6 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 84 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 88 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e6 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 6 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 6 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.180\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.505\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.080\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.240  \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 84 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 88\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 915\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896732713329,"sku":"NNC030337","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_74a679e7-8f32-4eee-b29a-1ad890b2dd9a.png?v=1763009222"},{"product_id":"4-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"4 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 110 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 115 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e4 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 4 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 4 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.230\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.555\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.080\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.340\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 110 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 115\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 1135\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896733335921,"sku":"NNC030338","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_4c69b698-4fe4-47e8-9b2d-389a22d6845f.png?v=1763009224"},{"product_id":"2-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"2 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 145 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 135 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e2 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 2 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 2 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.283 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.573\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.080\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.443 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 145\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 135\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 1447\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896733466993,"sku":"NNC030339","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_8ddb8aaf-c344-425e-a207-e379714a7c6f.png?v=1763009225"},{"product_id":"1-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"1 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 165 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 155 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e1 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 1 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 1 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.322\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.613\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.080\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.529 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 165 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 155\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 1730 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896733532529,"sku":"NNC030340","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_615b264d-dc9d-449a-b2a9-65d29b70d24b.png?v=1763009225"},{"product_id":"1-0-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"1\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 190 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 185 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 1\/0 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 1\/0 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.362\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.653 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.616 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 190\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 185\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 1987 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896733958513,"sku":"NNC030341","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_32dc8dc9-73a2-48f2-b480-cd52dc09854b.png?v=1763009228"},{"product_id":"2-0-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"2\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 220  amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 210 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 2\/0 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 2\/0 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.405 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.693\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.765\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 220 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 210\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 2421 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896734187889,"sku":"NNC030342","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_13513379-2c52-4318-9b13-88df670f3221.png?v=1759829687"},{"product_id":"3-0-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"3\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 250 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 245 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 3\/0 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 3\/0 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.456\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 3 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.743 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.873\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 250\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 245\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 2869 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896761942385,"sku":"NNC030343","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_ad96b263-1747-4aa4-8cc9-aeec7b61b3bb.png?v=1759829689"},{"product_id":"4-0-awg-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"4\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 285 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 285 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 4\/0 AWG 3C EPR\/PVC Cable, MV105 Power Cable, 4\/0 AWG 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.512\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 3 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.798\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 1.992\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 285\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 285\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 3384\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896762106225,"sku":"NNC030344","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_6114bc6b-ce04-41c9-b2a2-cef74751bba1.png?v=1763009235"},{"product_id":"250-mcm-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"250 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 315 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 315 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e250 MCM 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 250 MCM 3C EPR\/PVC Cable, MV105 Power Cable, 250 MCM 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.558 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 3 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.853 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 2.123\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 315\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 315\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 3868\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896763548017,"sku":"NNC030345","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_00d237fa-10f9-40b1-a58b-af4c91f2e1ad.png?v=1763009237"},{"product_id":"350-mcm-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"350 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 380 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 390 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e350 MCM 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 350 MCM 3C EPR\/PVC Cable, MV105 Power Cable, 350 MCM 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.661\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.958\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 2.349\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 380\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 390\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 5056\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896763711857,"sku":"NNC030346","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_e7813bf3-1fd0-41ab-a46f-f3d95acaca03.png?v=1763009238"},{"product_id":"500-mcm-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"500 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 460 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 475 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e500 MCM 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 500 MCM 3C EPR\/PVC Cable, MV105 Power Cable, 500 MCM 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.790 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.083 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.140\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 2.619\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 460 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 475\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 6770\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896763875697,"sku":"NNC030347","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_a8a91976-cda3-4b42-9540-578518b3d4a5.png?v=1759829689"},{"product_id":"750-mcm-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"750 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 570 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 585 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e750 MCM 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 750 MCM 3C EPR\/PVC Cable, MV105 Power Cable, 750 MCM 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.968 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.270\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.140\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 3.077\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 570\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 585\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 9722 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896764301681,"sku":"NNC030348","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_e33e132d-2c01-4cad-8384-671d9747e41e.png?v=1759829690"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/three-conductor-mv105-5kv-epr-pvc-133-medium-voltage-power-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}