{"title":"Three Conductor Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV - 25 kV","description":"","products":[{"product_id":"8-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"8 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e8 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 8 AWG 3C CPE Jacket, 5kV-25kV Cable, 8 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e : One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.13\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e  8\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.20\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 810\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086400614769,"sku":"NNC085MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_7a4e414a-2dd5-4f0d-9cdc-6da5e4c27f59.png?v=1763020980"},{"product_id":"6-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"6 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 6 AWG 3C CPE Jacket, 5kV-25kV Cable, 6 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e : One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.27\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 990 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086435676529,"sku":"NNC065MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_ebd64851-2748-4a1d-bc24-df037f057dea.png?v=1763020983"},{"product_id":"4-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"4 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4 AWG 3C CPE Jacket, 5kV-25kV Cable, 4 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e : One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.37\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1218 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086441738609,"sku":"NNC045MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_d60ab163-828f-4538-8565-af7bc5a756f0.png?v=1763020983"},{"product_id":"2-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"2 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2 AWG 3C CPE Jacket, 5kV-25kV Cable, 2 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.49\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1556 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086451143025,"sku":"NNC025MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_efab4b84-ac4d-401e-8963-0883160743ab.png?v=1763020985"},{"product_id":"1-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"1 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1 AWG 3C CPE Jacket, 5kV-25kV Cable, 1 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.55\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1815  \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086458188145,"sku":"NNC015MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_86e0e7fe-64a7-41fe-9456-fa762e631ec1.png?v=1763020985"},{"product_id":"1-0-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"1\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 1\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.63\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2094\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086463824241,"sku":"NNC10133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_a6e357e9-3e75-4067-95ba-ef8562ce534e.png?v=1763020986"},{"product_id":"2-0-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"2\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 2\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.79\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2557\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086473163121,"sku":"NNC20133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_16686d98-d158-4956-aa11-90d4cc8641e9.png?v=1763021109"},{"product_id":"3-0-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"3\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 3\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 3\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.89\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3017 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086480437617,"sku":"NNC30133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_502de1f3-a7f4-4ec1-97cd-fe1c580870f2.png?v=1759832263"},{"product_id":"4-0-awg-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"4\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 4\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.00\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3548\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086494495089,"sku":"NNC40133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_ab7c1623-5988-49f1-a5c1-3223ba30bf38.png?v=1763021111"},{"product_id":"250-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"250 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 250 MCM 3C CPE Jacket, 5kV-25kV Cable, 250 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.13\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4072 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086503539057,"sku":"NNC250133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_717bb843-dc0f-428c-8514-ee377f7685ea.png?v=1763021113"},{"product_id":"300-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"300 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 300 MCM 3C CPE Jacket, 5kV-25kV Cable, 300 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.23\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4657\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086511731057,"sku":"NNC300133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_3d5cb777-0ad3-4c41-a2da-e434187b1028.png?v=1759832263"},{"product_id":"350-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"350 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 350 MCM 3C CPE Jacket, 5kV-25kV Cable, 350 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.33\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5243 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086544073073,"sku":"NNC350133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_932d6780-c711-411f-bb09-f4e798801063.png?v=1763021113"},{"product_id":"400-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"400 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 400 MCM 3C CPE Jacket, 5kV-25kV Cable, 400 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.42\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5861 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086550331761,"sku":"NNC400133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_59d90acd-8686-4a0e-aeab-b7ab788d9682.png?v=1763021115"},{"product_id":"500-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"500 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 500 MCM 3C CPE Jacket, 5kV-25kV Cable, 500 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.64\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 7091 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086562455921,"sku":"NNC500133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_65767443-aab0-43cd-81b2-ee7f57a3a193.png?v=1763021116"},{"product_id":"600-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"600 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e600 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e600 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 600 MCM 3C CPE Jacket, 5kV-25kV Cable, 600 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 600 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.81\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.90\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 8462\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086573171057,"sku":"NNC600133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_3dca0cdc-ef4a-4805-8b5c-6cb69d49a6ca.png?v=1759832265"},{"product_id":"750-mcm-3c-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv","title":"750 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Copper MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e750 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 750 MCM 3C CPE Jacket, 5kV-25kV Cable, 750 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.91\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 3.11\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 10132 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086586114417,"sku":"NNC750133MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_69586587-fca7-4d0b-a1fe-19b35696d60e.png?v=1763021118"},{"product_id":"6-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"6 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 6 AWG 3C CPE Jacket, 5kV-25kV Cable, 6 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.39\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1108\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086601777521,"sku":"NNC088MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_df148f96-dfe0-4bfa-b59b-38d5e0ed5102.png?v=1759832267"},{"product_id":"4-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"4 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4 AWG 3C CPE Jacket, 5kV-25kV Cable, 4 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.48\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1343\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52086618358129,"sku":"NNC04115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_cfc11f2f-3472-4471-bd06-55d799e84834.png?v=1759832266"},{"product_id":"2-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"2 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2 AWG 3C CPE Jacket, 5kV-25kV Cable, 2 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.60\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1690 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088227103089,"sku":"NNC02115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_f55f4347-c3e3-42df-88e0-996bee2f994b.png?v=1763021124"},{"product_id":"1-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"1 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1 AWG 3C CPE Jacket, 5kV-25kV Cable, 1 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.67\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1955\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088235983217,"sku":"NNC01115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_929e96f0-6995-475b-8e0a-e1a8ada1c505.png?v=1763021124"},{"product_id":"1-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"1\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 1\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.82\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2364 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088238801265,"sku":"NNC10115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_52571b16-9739-43c9-aa2f-23932cc11995.png?v=1759832268"},{"product_id":"2-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"2\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 2\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.90\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2717  \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088256987505,"sku":"NNC20115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_5f435915-c9ab-4505-ae7e-adc794e0b5f7.png?v=1759832268"},{"product_id":"3-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"3\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 3\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 3\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.00\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3185  \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088278647153,"sku":"NNC30115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_85ed292a-dc3e-4fe4-a9b3-144329fcd15b.png?v=1759832270"},{"product_id":"4-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"4\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 4\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.12\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3724\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088295129457,"sku":"NNC40115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_7d401675-f250-4426-9a55-42ec1cfc00c3.png?v=1763021127"},{"product_id":"250-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"250 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 250 MCM 3C CPE Jacket, 5kV-25kV Cable, 250 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.24\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4258\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088353685873,"sku":"NNC250115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_4681be7f-f07d-4908-bfc7-78b2e0ddd897.png?v=1763021128"},{"product_id":"300-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"300 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 300 MCM 3C CPE Jacket, 5kV-25kV Cable, 300 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.35\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4851\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088367874417,"sku":"NNC300115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_affaa8e8-14f0-4e6d-b9f4-507bf25c83fa.png?v=1763021128"},{"product_id":"350-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"350 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 350 MCM 3C CPE Jacket, 5kV-25kV Cable, 350 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.44\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5445 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088380653937,"sku":"NNC350115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_f65a55b8-0b1e-4116-89d0-258124c40d54.png?v=1759832270"},{"product_id":"400-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"400 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 400 MCM 3C CPE Jacket, 5kV-25kV Cable, 400 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.54\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 6070 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088388223345,"sku":"NNC400115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_6cd75e8e-1004-42af-a19f-651283efe320.png?v=1763021130"},{"product_id":"500-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-115-mil-cpe-jacket-8-kv","title":"500 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 115 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 500 MCM 3C CPE Jacket, 5kV-25kV Cable, 500 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.82\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 7510 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088396022129,"sku":"NNC500115MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_26e073e1-8593-44fd-b88e-470dcbfca731.png?v=1763021131"},{"product_id":"6-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"6 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 6 AWG 3C CPE Jacket, 5kV-25kV Cable, 6 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.50\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1235 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088402739569,"sku":"NNC06140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_49a3f74c-fa63-4a47-9438-514dddcc14a5.png?v=1763021132"},{"product_id":"4-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"4 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4 AWG 3C CPE Jacket, 5kV-25kV Cable, 4 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.59\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1477\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52088417190257,"sku":"NNC04140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_6b3388e5-9d6e-495d-abbb-c4e6b4dc0107.png?v=1763021133"},{"product_id":"2-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"2 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2 AWG 3C CPE Jacket, 5kV-25kV Cable, 2 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.71\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1833\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091408908657,"sku":"NNC02140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_c521233c-7271-4bc4-bbb8-214a8e9593e2.png?v=1759832273"},{"product_id":"1-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"1 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1 AWG 3C CPE Jacket, 5kV-25kV Cable,1 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.85\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2229 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091444134257,"sku":"NNC01140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_3cd83c72-6a8d-4896-8bd1-a430d84035be.png?v=1763021143"},{"product_id":"1-0-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"1\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 1\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.93\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2526\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091457634673,"sku":"NNC10140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_018d771a-c63b-4154-9d13-ab007c6b62fa.png?v=1763021143"},{"product_id":"2-0-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"2\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 2\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.02\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2886 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091475362161,"sku":"NNC20140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_67398740-8d41-44e4-9449-da6d454e7ebf.png?v=1763021145"},{"product_id":"3-0-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"3\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 3\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 3\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.12\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3361\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091496726897,"sku":"NNC30140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_871fec66-5465-4fe6-905e-e536fa48c617.png?v=1763021146"},{"product_id":"4-0-awg-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"4\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 4\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.23\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3909 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091529363825,"sku":"NNC40140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_5b26da6c-b897-471c-b370-086e98d87721.png?v=1763021147"},{"product_id":"250-mcm-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"250 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 250 MCM 3C CPE Jacket, 5kV-25kV Cable, 250 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.35\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e  4452 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091540308337,"sku":"NNC250140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_93be302a-837e-43af-acea-a301ca53b8b2.png?v=1763021147"},{"product_id":"300-mcm-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"300 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 300 MCM 3C CPE Jacket, 5kV-25kV Cable, 300 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.46\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5054\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091561935217,"sku":"NNC300140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_a06b880d-9825-4e6a-9722-4228a6f69813.png?v=1759832275"},{"product_id":"350-mcm-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"350 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 350 MCM 3C CPE Jacket, 5kV-25kV Cable, 350 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.56\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5655 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091581497713,"sku":"NNC350140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_d572294b-3bab-43fd-8210-61ab77692b58.png?v=1759832275"},{"product_id":"400-mcm-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"400 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 400 MCM 3C CPE Jacket, 5kV-25kV Cable, 400 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.70\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 6384\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091687829873,"sku":"NNC400140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_fa9ebca5-ed63-4e30-8549-82874ec54156.png?v=1763021151"},{"product_id":"500-mcm-3c-copper-mv-105-tape-shielded-epr-133-insulation-140-mil-cpe-jacket-8-kv","title":"500 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Copper MV-105 Tape Shielded EPR 133% Insulation 140 mil CPE Jacket 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 500 MCM 3C CPE Jacket, 5kV-25kV Cable, 500 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.94\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 7752\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091725283697,"sku":"NNC500140MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_3c32e142-e61f-44e3-afc6-4cf8919cac0c.png?v=1763021151"},{"product_id":"2-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"2 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2 AWG 3C CPE Jacket, 5kV-25kV Cable, 2 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.94\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2180\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091752972657,"sku":"NNC02175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_a97a1be9-e94d-4459-9ecc-8912ac67c12b.png?v=1759832276"},{"product_id":"1-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"1 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1 AWG 3C CPE Jacket, 5kV-25kV Cable, 1 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.01\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2462\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091776958833,"sku":"NNC01175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_6e00aeaf-0184-410f-a73b-570dc3b5d53a.png?v=1763021153"},{"product_id":"1-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"1\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 1\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.09\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2767\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091800813937,"sku":"NNC10175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_1efdaa82-d725-4d63-a9d0-c52acffaf079.png?v=1763021154"},{"product_id":"2-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"2\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 2\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 2\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.17\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3137\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52091905311089,"sku":"NNC20175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_47de977c-2be5-4962-a90d-e6c05d90f62c.png?v=1763021157"},{"product_id":"3-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"3\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 3\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 3\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.27\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3623 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52092150120817,"sku":"NNC30175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_8eba463b-4e8e-4f22-992d-52bd3d7f98da.png?v=1763021163"},{"product_id":"4-0-awg-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"4\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 4\/0 AWG 3C CPE Jacket, 5kV-25kV Cable, 4\/0 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.39\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4183\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52092162081137,"sku":"NNC40175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_acd6c665-dd0c-4cad-8e35-668b23282fbb.png?v=1763021165"},{"product_id":"250-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"250 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 250 MCM 3C CPE Jacket, 5kV-25kV Cable, 250 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.51\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4739\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52092176695665,"sku":"NNC250175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_37f23b03-7f7f-4d16-bab4-67e2a08ebfb0.png?v=1763021165"},{"product_id":"300-mcm-3c-copper-mv-105-tape-shielded-epr-100-insulation-175-mil-cpe-jacket-15-kv","title":"300 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-06-mv105-3c-epr-cpe_removed_1.pdf?v=1737110810\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Copper MV-105 Tape Shielded EPR 100% Insulation 175 mil CPE Jacket 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 300 MCM 3C CPE Jacket, 5kV-25kV Cable, 300 MCM 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-105.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use for all cable sizes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e : Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003ePhase ID:\u003c\/strong\u003e Colored strings (black, red and White yarns.)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.66\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5448\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52092195340657,"sku":"NNC300175MV-105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_f806bc49-5a44-4bdd-a460-69981d6da176.png?v=1763021166"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/three-conductor-copper-mv-105-tape-shielded-epr-insulated-cpe-jacket-5-kv-25-kv.oembed?page=4","provider":"NassauNationalCable","version":"1.0","type":"link"}