16 AWG 16C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable

16 AWG 16C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable
Roll over image to Zoom

16 AWG 16C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable

SKU:
sumsave®-as-z1z1-k-bare-copper-unshielded-halogen-free-0-6-1kv-cpr-flexible-cable

Select a Gauge

16 AWG 16C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

16 AWG 16C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable

Allowable Ampacity for 16 AWG 16C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable: 100 Amps

Application:

Z1Z1-K (AS) CPR cables comply with the construction product classification criteria according to CPR Regulation 305/2011 and the EN 50575 standard, being those indicated for fixed installations, protected or not, where in case of fire it is required a low emission of smoke and corrosive gases, such as public places, hospitals, schools, shopping centers and airports. They are suitable for indoor and outdoor installations. Appropriate for installations where you want to increase fire protection.

Suitable for the following installations:
• ITC-BT 20 Interior or reception installations
• ITC-BT 28 Public premises
• ITC-BT 29 Installations in premises with risk of fire or explosion
• ITC-BT 30 Installations in premises with special characteristics

Also Known as: 

Sumsave Cable, Sum Cable, Z1Z1-K Cable, Flexible Cable, Sumsave® (AS) Z1Z1-K Cable, CPR Cable

Design:

• Flexible electrolytic copper conductor (Class 5) according to UNE-EN 60228, EN 60228 and IEC 60228
• Halogen-free thermoplastic polyolefin insulation with characteristics according to Table 1 Annex 1 of the UNE 21123-4 / UNE-HD 603-4 standard Conductor
• identification according to UNE 21089, HD 308 S2 or EN 50334
• Thermoplastic polyolefin cover type DMZ-E according to UNE 21123-4 and UNE-HD 603-1 - ST8according to IEC 60502-1
• Green color

Technical Data:

Rated voltage 0.6/1 kV Test
voltage 3,500 V AC Maximum
temperature 70 °C
Minimum bending radius 6 x Outside diameter in fixed installation
Service temperature -40 °C to +70 °C

Specification:

AWG Size: 16
Number of Conductor: 16

Conductor: Bare Copper
N x S: 16G 1.50 mm²
Conductor resistance at 20°C: 13.30 ohm/km
Outer Diameter approx: 17.10 mm
Rated Voltage: 0.6/1kV
Weight: 339.34 lbs/MFT


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color