{"title":"RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"","products":[{"product_id":"1-core-16-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 16 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 16 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 16 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e16\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e5.3 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e18.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e24.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.3 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e1.160 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e0.677 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 94.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 35.5938px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e804000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eN02E01C016BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eICC Cable Corp :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eNEK-RFOU1C16-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406314254490,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_12b961f2-7e19-4e4c-9f4f-1029eec1f125.png?v=1759814214"},{"product_id":"1-core-25-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 25 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 25 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 25 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e25 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e6.6 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e19.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e1.7 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e25.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.3 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.734 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e0.797 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C025BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C25-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406334832794,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_2357d926-f674-4043-a747-5aeb0b9e2213.png?v=1762488759"},{"product_id":"1-core-35-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 35 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 35 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 35 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e35 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e7.9 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e21.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e1.7 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e26.7 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.4 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.529 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e0.903 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 94.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 35.5938px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e804002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eN02E01C035BAKRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eNEK-RFOU1C35-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406402662554,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_be04fa4c-b28b-4ca7-ba8b-db8f7251796a.png?v=1762488761"},{"product_id":"1-core-50-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 50 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 50 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 50 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e50 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e9.1 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e22.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e28.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.4 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.391 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e1.044 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20080191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C050BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C50-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406425370778,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_6186661f-7a53-4399-a1f8-91752e1aa330.png?v=1759814215"},{"product_id":"1-core-70-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 70 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 70 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 70 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e70 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e11 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e24.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e30.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.5 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.270 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e1.249 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20113313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C070BAKRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C70-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406491365530,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_8f0b3b81-d6d4-4fc9-9828-2be99454f914.png?v=1762488762"},{"product_id":"1-core-95-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 95 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 95 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 95 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e95 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e12.9 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e26.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e1.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e32.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.6 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.195 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e1.503 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 94.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 35.5938px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e804005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eN02E01C095BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eNEK-RFOU1C95-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406505652378,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_e9a5f7af-53b8-48c5-81a3-5849ac628a0a.png?v=1759814215"},{"product_id":"1-core-120-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 120 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 120 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 120 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e120  mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e14.5 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e28.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e34.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.7 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.154 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e1.764 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20076157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C120BAKRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C120-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406521807002,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_a560ef9e-c6d0-44e6-a78b-e9f9fb061ac3.png?v=1759814217"},{"product_id":"1-core-150-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 150 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 150 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 150 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e150 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e16.2 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e29.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e36.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.7 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.126 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e2.018 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C150BAKRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C150-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406542712986,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_c68cd2ef-36b9-44cb-b0a8-995e460e9ae1.png?v=1762488765"},{"product_id":"1-core-185-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 185 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 185 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 185 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e185\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e18.0 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e31.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e38.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e1.8 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.100 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e2.406 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20098204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C185BAKRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C185-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406560702618,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_87ef93dd-e063-48b0-9974-4f8bfe0d2075.png?v=1762488765"},{"product_id":"1-core-240-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 240 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 240 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 240 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e240\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e61 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e20.6 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e34.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e41.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.0 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0762 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e2.977 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20077819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C240BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C240-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406592782490,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_ec947927-b557-4b2c-8cdd-565a908707e4.png?v=1762488766"},{"product_id":"1-core-300-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 300 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 300 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 300 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e300\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e61 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e23.1 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e36.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e44.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.1 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0607 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e3.500 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20076156\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C300BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C300-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406628630682,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_50f6b67e-a863-4e8c-b526-8bc0ccb56122.png?v=1762488767"},{"product_id":"1-core-400-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 400 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 400 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 400 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e400 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e61 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e26.1 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e40.7 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e48.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.2 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0475 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e4.332 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C400BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C400-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406667329690,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_ba496a3c-de0c-4bef-b5e3-cf17a45749a7.png?v=1762488769"},{"product_id":"1-core-500-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 500 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 500 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 500 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e500 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e61 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e29.2 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e43.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e51.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.4 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0369 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e5.038 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 94.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 35.5938px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e804012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eN02E01C500BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eNEK-RFOU1C500-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406694854810,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_ce372460-f079-4b00-aed1-c553cad73014.png?v=1759814217"},{"product_id":"1-core-630-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"1 Core 630 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Core 630 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 1 Core 630 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e1 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e630\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e91 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e33.2 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e47.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e56.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.5 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0286 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e6.258\u003cstrong\u003e \u003c\/strong\u003eLbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E01C630BAKRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU1C630-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406739452058,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_6ae4a9a0-7ee9-4b52-86d1-614f5acc5bf2.png?v=1762488771"},{"product_id":"3-core-16-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 16 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 16 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 16 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e16\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e5.3 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e38.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e46.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.1 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e1.160 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e2.279 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C016BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C16-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406761111706,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_9b9acdf7-1479-4c7f-aa6c-3f9524e81503.png?v=1762488773"},{"product_id":"3-core-25-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 25 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 25 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 25 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e25 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e6.6 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e41.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e49.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.3 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.734 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e2.695 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C025BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C25-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406850011290,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_0a9e146d-91b3-444d-af09-ca85d87a45aa.png?v=1762488776"},{"product_id":"3-core-35-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 35 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 35 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 35 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e35 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e7.9 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e43.7\u003cstrong\u003e \u003c\/strong\u003emm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.7 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e51.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.4 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.529 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e3.083 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C035BCCRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C35-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406894149786,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_4c6ed228-5220-43e2-b8b2-b437fe13296a.png?v=1762488777"},{"product_id":"3-core-50-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 50 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 50 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 50 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e50 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e9.1 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e46.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e54.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.5 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.391 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e3.556 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C050BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C50-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406937206938,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_9037145e-f4cb-470f-a2d9-ca389d61382f.png?v=1762488778"},{"product_id":"3-core-70-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 70 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 70 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 70 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e70\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e11 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e50.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e59.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.7 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.270 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e4.332 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20076430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C070BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C70-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40406985080986,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_68090229-6e2a-44ee-8322-51e566927de9.png?v=1762488780"},{"product_id":"3-core-95-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 95 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 95 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 95 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e95\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e12.9 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e54.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e63.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.9 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.195 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e5.221 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20076152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C095BCCRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C95-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407011066010,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_c6bdb36d-aff8-4a7e-aede-ce7926ca8c51.png?v=1762488781"},{"product_id":"3-core-120-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 120 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 120 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 120 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3\u003cstrong\u003e \u003c\/strong\u003eCore\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e120\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37  EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e14.5 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e58.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e67.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.0 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.154 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e6.026 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20086406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C120BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C120-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407027777690,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_903a79d1-3d5f-4722-92f7-b2710028614e.png?v=1762488782"},{"product_id":"3-core-150-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 150 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 150 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 150 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cablee : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e150 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e16.2 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e61.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e71.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.2 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.126 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e6.900\u003cstrong\u003e \u003c\/strong\u003eLbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e20076162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C150BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C150-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407061790874,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_42573046-7a63-4dd5-9d2e-8982e3c5f3e7.png?v=1762488782"},{"product_id":"3-core-185-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 185 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 185 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 185 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e185 mm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e18 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e66.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e75.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.3 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.100 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e8.051 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 94.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 35.5938px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e20077823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eN02E03C185BCCRD12 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eNEK-RFOU3C185-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407112515738,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_927be65f-28d3-4149-b2ff-e46512cf2cd3.png?v=1762488784"},{"product_id":"3-core-240-mm-rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 240 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 240 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 240 mm² RFOU 6\/10KV Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• Conductor Nominal Area : \u003c\/strong\u003e240\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e61 EA\u003cbr\u003e\u003cstrong\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e20.6 mm\u003cbr\u003e\u003cstrong\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e72.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e83.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.6 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0762 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e10.047 Lbs\/Ft\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e804029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eIncore Cables :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eN02E03C240BCCRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C240-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407150198938,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_fd15b922-6625-44b4-872d-06ad2af52aa3.png?v=1762488784"},{"product_id":"3-core-25-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 25 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 25 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 25 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e25 mm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e16 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 7 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e6.6 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e5.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.0 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e41.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e49.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.3 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.734 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e2.836 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C25E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407189323930,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_03e6f862-9b35-44ca-9885-f3158b31eace.png?v=1762488785"},{"product_id":"3-core-35-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 35 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 35 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 35 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e35 mm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e25 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e7\u003cstrong\u003e \u003c\/strong\u003eEA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 7 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e7.9 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e6.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e44.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.7 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e52.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.4 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.529 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e3.302 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C35E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407229923482,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_c9283a23-c1ca-4943-8da5-1bf0ddf83e6e.png?v=1759814218"},{"product_id":"3-core-50-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 50 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 50 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 50 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e50 \u003c\/span\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e25 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 7 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e9.1 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e6.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e46.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e54.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.5 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.391 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e3.754 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C50E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407339597978,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_d7941579-a188-4e1a-9100-93eb012a653d.png?v=1759814219"},{"product_id":"3-core-70-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 70 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 70 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 70 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e70\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e35 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 7 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e11.0 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e7.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.2 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e50.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e2.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e59.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.7 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.270 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e4.600 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C70E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407367778458,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_0f8712c0-e4e4-4a3b-ad55-d3486c8d99c1.png?v=1759814220"},{"product_id":"3-core-95-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 95 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 95 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 95 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e95\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e50 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e19 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 19 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e12.9 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e9.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e55.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.1 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e64.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e2.9 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.195 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e5.602 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C95E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407390388378,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_b9545b0c-ea4b-4af7-b572-efc1a9b308de.png?v=1759814220"},{"product_id":"3-core-120-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 120 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 120 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 120 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e120\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e70 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 19 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e14.5 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e11.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.4 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e59.2 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e68.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.0 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.154 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e6.590 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C120E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407414571162,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_d61eb6b9-4f41-46d8-b0f6-fd72ebbef81d.png?v=1759814221"},{"product_id":"3-core-150-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 150 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 150 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 150 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e150\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e95 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 19 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e16.2 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e12.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e63.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e73.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.2 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.126 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e7.754 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C150E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407439114394,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_97262ca9-bb82-4713-9146-859f63c3895e.png?v=1762488791"},{"product_id":"3-core-185-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 185 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 185 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 185 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e185\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e95 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e37 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 19 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e18 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e12.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e67.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e77.3 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.4 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.100 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e8.834 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C185E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407450910874,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_dd1dd974-601d-4c74-93e6-3d8199a1217d.png?v=1759814221"},{"product_id":"3-core-240-mm-rfou-6-10kv-w-earth-flame-retardant-halogen-free-high-voltage-power-cable","title":"3 Core 240 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Core 240 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor 3 Core 240 mm² RFOU 6\/10KV W\/ Earth Flame Retardant Halogen Free High Voltage Power Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eRFOU 6\/10KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, High Voltage Power Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConstruction :\u003cbr\u003e\u003cbr\u003e• Conductor :\u003c\/strong\u003e Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Screen : \u003c\/strong\u003eSemi Conducting Layer (Tape\/Compound)\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation \u003c\/strong\u003e\u003cb\u003e: - \u003c\/b\u003eCode - R\u003cbr\u003e\u003cb\u003e                       - \u003c\/b\u003eEPR as per IEC 60092-360\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Screen : \u003c\/strong\u003e- Non-metallic Part : Semi-conducting Layer (Tape \/ Compound)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eMetallic Part : Copper Wire Braid\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e                                   - \u003c\/strong\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part                                                   \u003cbr\u003e\u003cbr\u003e•\u003cstrong\u003e Cabling \u003c\/strong\u003e: - Three Metallic Braided Conductors Shall Be Cabled\u003cbr data-mce-fragment=\"1\"\u003e                  - Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003cbr data-mce-fragment=\"1\"\u003e                  - Suitable Tape(S) May Be Applied On The Cabled Core\u003cbr data-mce-fragment=\"1\"\u003e                  - A Filler May Be Applied To Obtain A Circular Cable\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Covering : - \u003c\/strong\u003eCode F\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e                               - Flame Retardant Halogen Free Thermoset Compound\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• Armor : \u003c\/strong\u003e- Code O\u003cbr\u003e\u003cstrong\u003e                \u003c\/strong\u003e- Braid Of Tinned Copper Wire (0) \/ Bronze Wire (B) \/ Galvanized Steel Wire (C)\u003cbr data-mce-fragment=\"1\"\u003e                \u003cspan data-mce-fragment=\"1\"\u003e- Code (B,C)\u003cbr\u003e\u003c\/span\u003e                - A Suitable Separator Tape(S) May Be Applied Under\/Over The Armor\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSheath : - \u003c\/strong\u003eCode U\u003cbr\u003e              - SHF2 As Per IEC 60092-360\u003cbr data-mce-fragment=\"1\"\u003e              - Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant\u003cbr data-mce-fragment=\"1\"\u003e              - Outer Sheath Color : Red\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCore Identification : - \u003c\/strong\u003e3C : Off-white, Black, Red\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication Standards :\u003cbr\u003e\u003cbr\u003e• Design Guide : \u003c\/strong\u003eNEK-606 \u0026amp; IEC 60092-354\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Flame Retardant : \u003c\/strong\u003eIEC 60332-1 \u0026amp; IEC 60332-3 Category A\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Halogen Content : \u003c\/strong\u003eIEC 60754-1, 0.5%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cold Bend \/ Impact : \u003c\/strong\u003eCSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e\/-35\u003cspan data-mce-fragment=\"1\"\u003eºC\u003c\/span\u003e)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Mud \/ Oil Resistant : \u003c\/strong\u003eNEK 606 (Category A,B,C,D)\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Smoke Light Transmittance : \u003c\/strong\u003eIEC 61034, 60%\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Sunlight (UV) Resistant : \u003c\/strong\u003eUL 1581\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003cbr\u003e•\u003c\/strong\u003e \u003cstrong\u003eNo of Cores : \u003c\/strong\u003e3 Core\u003cbr\u003e\u003cstrong\u003e• No of Earth : \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Nominal Area : \u003c\/strong\u003e240\u003cstrong\u003e \u003c\/strong\u003emm²\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Nominal Area : \u003c\/strong\u003e120 mm²\u003cstrong\u003e\u003cbr\u003e• Conductor Min. No. Of Wires : \u003c\/strong\u003e61 EA\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Min. No. Of Wires\u003cspan data-mce-fragment=\"1\"\u003e :\u003c\/span\u003e\u003c\/strong\u003e 37 EA\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Max.Over All Dia : \u003c\/strong\u003e20.6 mm\u003cbr\u003e\u003cstrong\u003e• Earth Conductor Max.Over All Dia : \u003c\/strong\u003e14.5 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Insulation : \u003c\/strong\u003e3.4 mm\u003cbr\u003e\u003cstrong\u003e• Earth Thickness of Insulation : \u003c\/strong\u003e1.6 mm\u003cstrong\u003e\u003cbr\u003e• Dia Of Copper Wire For Braid :\u003c\/strong\u003e 0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Inner Covering : \u003c\/strong\u003e1.8 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Nominal Dia. Inner Covering : \u003c\/strong\u003e74.0 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Dia. of Wire for Armour : \u003c\/strong\u003e0.4 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Thickness of Sheath : \u003c\/strong\u003e3.9 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Nominal : \u003c\/strong\u003e84.6 mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Overall Diameter Tolerance: \u003c\/strong\u003e3.7 ±mm\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conductor Resistance (at 20°C) (Max.) : \u003c\/strong\u003e0.0762 Ω\/km\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Test Voltage : \u003c\/strong\u003e21.0 V\/5min.\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Cable Weight : \u003c\/strong\u003e10.979 lbs\/ft\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\" data-mce-style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eNEK-RFOU3C240E-10KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":40407472832666,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Untitled_cdee898e-55ac-4eac-9a43-8eda88f70ae5.png?v=1759814223"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/rfou-6-10kv-flame-retardant-halogen-free-high-voltage-power-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}