567-18-3508 14 AWG 8P Tin Coated Copper Shield Silicone Al Mylar Armor C-L-X Okotherm CIC SP-OS Marine Cable
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
567-18-3508 14 AWG 8P Tin Coated Copper Shield Silicone Al Mylar Armor C-L-X Okotherm CIC SP-OS Marine Cable
Allowable AmpacityĀ for 567-18-3508 14 AWG 8P Tin Coated Copper Shield Silicone Al Mylar Armor C-L-X Okotherm CIC SP-OS Marine Cable:100 Amps
About:
The Tin Coated Copper Shield Silicone Al Mylar Armor C-L-X Okotherm CIC SP-OS Marine Cable is designed for use in challenging marine and offshore environments. This cable offers excellent protection against corrosion, mechanical damage, and electromagnetic interference (EMI), ensuring reliable performance in critical control and instrumentation applications.
Also Known As:
ā¢Ā Okotherm Marine Cable
ā¢Ā Tin Coated Copper Shield Marine Cable
ā¢Ā CIC (Control and Instrumentation Cable) Marine Cable
ā¢Ā C-L-X (Continuous Interlocking Armor) Marine Cable
ā¢Ā SP-OS (Silicone Protected Overall Shield) Marine Cable
Application:
ā¢Ā Okotherm CIC 600 volt instrumentation cables are used in systems where, in the event of aĀ fire, circuit integrity is required in order to maintain a process orĀ to safely shut down the process. Fire resistance is determined by compliance to the IEC 60331 circuit integrity fireĀ test. Okotherm CIC cables maintain circuit integrity based on qualification to IEC standardĀ 60331, for all temperatures and times up to andĀ including 2000°F for three hours. When exposed to a fire, the Okotherm CIC insulationĀ becomes an electrically insulating ceramic-likeĀ ash that is capable of maintaining the operatingĀ voltage.
ā¢Ā Okotherm CIC C-L-X Type MC-HL cablesĀ with the impervious, continuous aluminumĀ corrugated sheath are recommended as an alternative to a wire conduit system. TheseĀ cables may be installed indoors or outdoors, inĀ wet or dry locations, as open runs of cable secured to supports not more than six feet apart,Ā in cable tray, as an aerial cable on a messenger, in any approved raceway, directĀ burial, or encased in concrete. They are alsoĀ approved for use in Class I & II, Division 1Ā and 2, Class III, Division 1 and 2 and Zones 1 & 2 hazardous locations per NEC Articles
501, 502, 503, and 505.
ā¢Ā The isolated individual shields over each pair or triad, when properly grounded, prevent crosstalk or capacitive coupling between adjacent pairs or triads which occurs with acĀ signals, particularly the pulse type.Ā The overall shield eliminates most of theĀ static interference from the electric fieldĀ radiated by power cables and other electricalĀ equipment.
ā¢Ā Okotherm CIC 600 volt instrumentation cables should be considered on circuitsĀ designed for fire detection and suppression,Ā alarms, communication, circuits requiringĀ redundancy and personnel egress.
Standards:
ā¢Ā IEC 60092-350:Ā General construction and test methods of shipboard electrical cables
ā¢Ā IEC 60092-353:Ā Electrical installations in ships ā Part 353: Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1 kV and 3 kV
ā¢Ā IEEE 45:Ā IEEE Recommended Practice for Electrical Installations on Shipboard
ā¢Ā UL 1309:Ā Marine Shipboard Cable
ā¢Ā Lloyd's Register, DNV-GL, ABS (American Bureau of Shipping) certifications
Construction:
⢠Conductor: Nickel or tin coated copper
ā¢Ā Insulation:Ā Okotherm ThermosetĀ Silicone, with FR tape if required
ā¢Ā Braid:Ā Fiber Glass Braid
ā¢Ā Color Code:Ā ICEAĀ S-73-532, Method 7
ā¢Ā Group Shield:Ā Aluminum-mylar tape overlapped to provide 100% coverage, and aĀ 7 strand tin or nickel coated copper drain wire,Ā two sizes smaller than the conductor. All groupĀ shields are completely isolated from each other.
⢠Assembly: Pairs or triads assembled with left hand lay. Fiberglass fillers included where required to provide a round cable.
⢠Cable Shield: Aluminum-mylar tape overlapped to provide 100% coverage and a 7-strand tin or nickel coated copper drain wire, same size as conductors.
⢠Armor-C-L-X: Continuously Welded and Corrugated Aluminum
⢠Outer Jacket: Black PVC
Features:
ā¢Ā UL Listed as Type MC-HL cable E38916Ā and Marine Shipboard Cable E137931.
ā¢Ā UL Listed for cable tray use, direct burialĀ (2/C 14 AWG and larger) and sunlight resistant.
ā¢Ā Passes the IEEE 383-1974 and IEEEĀ 1202-1991 vertical tray flame tests.
ā¢Ā Passes the 210,000 BTU ICEA T-29-520Ā Vertical Tray Flame Test.
ā¢Ā Complete pre-packaged, factory-testedĀ wiring system.
ā¢Ā Individual pairs or triads are numbered andĀ color coded for simplified hook-up.
ā¢Ā C-L-X cables are quality control inspectedĀ to meet or exceed applicable UL standards.
ā¢Ā 90°C continuous operating temperature inĀ all types of installations.
ā¢Ā 130°C emergency rating.
ā¢Ā 250°C short circuit rating.
ā¢Ā Good EMI shielding characteristics.
ā¢Ā Individual units are completely isolated forĀ maximum noise rejection.
ā¢Ā Impervious, continuous metallic sheath ex- cludes moisture, gases and liquids.
ā¢Ā Lower installed system cost than conduit orĀ EMT systems.
ā¢Ā Provides excellent grounding safety
ā¢Ā Excellent compression and impactĀ resistance.
ā¢Ā Continuous long lengths.
ā¢Ā Minimum installation temperature of -40°CĀ or °F.
ā¢Ā American Bureau of Shipping (ABS) listedĀ as CWCMC Type MC-HL.
ā¢Ā Optional LSZH jacket available.
ā¢Ā Fire Resistant - Qualified to meet IECĀ 60331, -11 & -21, including temperature andĀ time up to 2000F for 3 hours, respectively.
ā¢Ā Fire Resistant - Qualified to meet the Hy- drocarbon Pool Circuit Integrity Fire Test, uti- lizing the UL 1709 time-temperature curve,Ā with minimum requirements of 65,000Ā BTU/h-ft2 heat flux, 2000F flame tempera- ture, 30 minute test duration, and 15A load.
Specifications:
⢠Conductor Size AWG: 14(7X)
ā¢Ā Number of Pairs: 8
⢠Number of Triads: -
⢠C-L-X O.D (Inches): 1.47
⢠C-L-X O.D (mm): 37.2
ā¢Ā Jacket Thickness (miles):Ā 50
ā¢Ā Nominal Cable O.DĀ (Inches): 1.58
ā¢Ā Nominal Cable O.DĀ (mm): 40.0
⢠Cross Sectional Area (sq. in): 1.95
ā¢Ā Approx. Net Weight: 885
⢠Part Number: 567-18-3508