112-16-2894 1/0 AWG 3C 6AWG Gnd Tin Coated Copper Unshielded Okonite FMR-N Okolon TS-CPE Power And Control Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
112-16-2894 1/0 AWG 3C 6AWG Gnd Tin Coated Copper Unshielded Okonite FMR-N Okolon TS-CPE Power And Control Cable
Allowable Ampacity for 112-16-2894 1/0 AWG 3C 6AWG Gnd Tin Coated Copper Unshielded Okonite FMR-N Okolon TS-CPE Power And Control Cable:100 Amps
About:
The 112-16-2894 1/0 AWG 3C 6AWG Gnd Tin Coated Copper Unshielded Okonite FMR-N Okolon TS-CPE Power And Control Cable is designed for robust power and control applications. It features tin-coated copper conductors and a durable Okolon TS-CPE jacket, making it suitable for industrial environments and direct burial. This cable is ideal for ensuring reliable electrical connections in demanding settings, complying with NEC and IEEE standards for safety and performance.
Also Known As:
• Okonite 1/0 AWG 3C FMR-N Cable
• Okolon TS-CPE Unshielded Cable
Application:
Okonite FMR-N Power and Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.
Standards:
• IEEE Standards: Meets specific IEEE standards for power and control cables, ensuring reliability and safety in electrical applications.
• UL Listing: Typically UL listed, confirming it meets the safety requirements set by Underwriters Laboratories for electrical cables.
• NEC Compliance: Complies with the National Electrical Code (NEC) specifications, which govern the installation of electrical wiring and equipment in the United States.
Construction:
• Conductors: Tin Coated Copper per ASTM B-33, Class B stranded per ASTM B-8.
• Insulation: Okonite FMR-N meets or exceeds the electrical and physical requirements of ICEA S-73-532 & S-95-658.
• Color Coding: Base colors and tracers as shown on reverse of Data Sheet. Sizes 8 AWG and larger: surface printing of numbers per ICEA Method 4.
• Assembly: Conductors cabled using flame and moisture resistant fillers.
• Overall Jacket: The Okolon TS-CPE compound meets or exceeds the requirements of ICEA S-73-532 and S-95-658.
Features:
• Qualified as Class 1E cable
• Flame retardant - passes the IEEE 383 and 1202 flame test requirements.
• Quality Assurance traceability
• 90°C rated cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.
• Mechanically rugged.
• Flexible, easy to install and terminate.
• Color or number coded conductors.
• Resistant to water, oil and most chemicals.
• Thermally stable at elevated temperatures.
• High insulation resistance, even at elevated temperatures.
• Small diameter, lightweight.
Specifications:
• Conductor Size AWG/kcmil: 1/0(19X)
• Number of Conductors: 3
• Insulation Thickness (miles): 55
• Grounding Conductor AWG: 6
• Jacket Thickness - mils: 80
• Jacket Thickness - mm: 2.03
• Approx. O.D. - Inches: 1.22
• Approx. O.D. -mm: 31.0
• 90°C Wet or Dry (1): 166
• Approx. Net Weight: 1621
• Part Number: 112-16-2894
*Data provided on this page is subject to change based on different manufacturers' variances