{"title":"Okoguard Stranded Uncoated Copper Shield Okoclear-TP MV-105 15KV Power Cable","description":"","products":[{"product_id":"115-23-3352-1-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3352 1\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e115-23-3352 1\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3352 1\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 1\/0 American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 1\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 53.5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.74\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.05\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 26.7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 790\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 215\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 215\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 290\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3352\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693050294426,"sku":"115-23-3352","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_972c55cc-d6ff-4b3a-a718-c212c3018802.png?v=1762995450"},{"product_id":"115-23-3353-2-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3353 2\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3353 2\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3353 2\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 2\/0 American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 2\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 67.4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.78\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.84\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.09\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 27.7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 900\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 255\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 245\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 335\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3353\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693133557914,"sku":"115-23-3353","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_f1a4bfb3-6012-4dd7-82e8-54b1bd3ad81a.png?v=1762995450"},{"product_id":"115-23-3354-3-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3354 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3354 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3354 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 3\/0 American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 3\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 85.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.83\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.89\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.14\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 29.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 1040\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 290\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 275\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 385\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3354\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693140308122,"sku":"115-23-3354","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_ab52e5cf-af5d-4828-af85-e771e2116414.png?v=1759827763"},{"product_id":"115-23-3355-4-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3355 4\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3355 4\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3355 4\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 4\/0 American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 4\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3½\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 107.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.87\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.93\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.19\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 30.2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 1200\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 330\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 315\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 445\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3355\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693154431130,"sku":"115-23-3355","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_418ee494-b459-4f6c-afe8-23396eeb949c.png?v=1759827764"},{"product_id":"115-23-3356-250-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3356 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3356 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3356 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 250 MCM American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 250\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3½\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 127.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.93\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.99\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.25\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 31.8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 1365\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 365\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 345\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 495\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3356\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693166588058,"sku":"115-23-3356","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_6cadfbd7-3011-429d-811e-7db5f864015e.png?v=1762995453"},{"product_id":"115-23-3357-350-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3357 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3357 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3357 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 350 MCM American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 350\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 4\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 177.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.02\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 1.08\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.33\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 33.8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 1720\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 440\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 415\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 610\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3357\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693179891866,"sku":"115-23-3357","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_276e5d94-1b21-43c5-aedb-52bd95c240b2.png?v=1759827764"},{"product_id":"115-23-3358-500-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3358 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3358 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3358 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 500 MCM American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 500\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 4\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 253.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.13\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 1.19\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.44\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 36.6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 2245\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 535\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 500\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 765\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3358\u003c\/span\u003e\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44693184282778,"sku":"115-23-3358","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_a1dd5aec-2f08-4126-9996-4b6e36a82fc1.png?v=1762995455"},{"product_id":"115-23-3359-750-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3359 750 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e115-23-3359 750 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3359 750 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 750 MCM American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 750\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 5\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 380.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.31\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 1.37\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.62\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 41.1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 3130\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 655\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 610\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 990\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3359\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44693187068058,"sku":"115-23-3359","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_8eff8c22-4206-4a97-9f5d-beb1c3538680.png?v=1762995455"},{"product_id":"115-23-3360-1000-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-175mils-15kv-power-cable","title":"115-23-3360 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3360 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3360 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable is a 1000 MCM American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhile the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 1000\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 5\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 507.0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.47\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 1.53\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.78\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 45.2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 4010\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 755\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 690\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 1185\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3360\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44693190738074,"sku":"115-23-3360","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_2f6a2bbd-378a-48ab-86f3-28d9f866743f.png?v=1759827766"},{"product_id":"115-23-3363-1-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3363 1\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e115-23-3363 1\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3363 1\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 1\/0 AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 1\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3½\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 53.5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.82\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.88\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.13\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 28.7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 870\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 215\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 215\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 290\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3363\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44693192605850,"sku":"115-23-3363","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_c3f6ef4a-1aa9-413b-8472-b3db4fdeb1c1.png?v=1762995456"},{"product_id":"115-23-3364-2-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3364 2\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3364 2\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3364 2\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 2\/0 AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e 2\/0\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3½\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 67.4 \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 0.86\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e 0.92\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 1.17\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e 29.7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e 985\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e 255\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e 245\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e 335\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e 115-23-3364\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44693209841818,"sku":"115-23-3364","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_70fa6c04-2763-48c2-b111-7f5260f55f3f.png?v=1762995457"},{"product_id":"115-23-3365-3-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3365 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"115-23-3365 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\"}' data-sheets-root=\"1\"\u003e115-23-3365 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3365 3\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 3\/0 AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 3\/0\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3½\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 85.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 0.92\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 0.98\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.23\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 31.2\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 1140\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 290\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 275\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 385\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3365\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842765222042,"sku":"115-23-3365","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_4e6923f3-f5bd-435d-adb9-15a8697ad986.png?v=1759828114"},{"product_id":"115-23-3366-4-0-awg-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3366 4\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3366 4\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3366 4\/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 4\/0 AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 4\/0\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 3½\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 107.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 0.96\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.27\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 32.3\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 1300\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 330\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 315\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 445\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3366\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842767974554,"sku":"115-23-3366","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_decbd776-1a3a-4d1a-9c42-9de19abde9a0.png?v=1762997198"},{"product_id":"115-23-3367-250-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3367 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3367 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3367 250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 250 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e 4\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 127.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.01\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.07\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.33\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 33.8\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 1460\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 365\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 345\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 495\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3367\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842771316890,"sku":"115-23-3367","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_a4c6bbf0-5eb8-435d-abc7-25a4d35f2dfc.png?v=1759828116"},{"product_id":"115-23-3368-350-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3368 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"115-23-3368 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\"}' data-sheets-root=\"1\"\u003e115-23-3368 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3368 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 350 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 177.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.10\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.16\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.42\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 36.1\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 1830\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 440\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 415\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 610\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3368\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842774790298,"sku":"115-23-3368","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_da62e3a2-b6d9-4ba0-9720-955ac806832e.png?v=1759828116"},{"product_id":"115-23-3369-500-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3369 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"115-23-3369 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\"}' data-sheets-root=\"1\"\u003e115-23-3369 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3369 500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 500 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 253.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.22\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.28\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.54\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 39.1\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 2370\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 535\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 500\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 765\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3369\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842777804954,"sku":"115-23-3369","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_5ea4a677-0e94-4d17-a7bf-c5badeef51d4.png?v=1759828117"},{"product_id":"115-23-3370-750-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3370 750 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e115-23-3370 750 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3370 750 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 750 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 380.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.40\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.46\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 80\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.03\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.71\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 43.4\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 3270\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 655\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 610\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 990\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3370\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842780491930,"sku":"115-23-3370","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_4137be86-ab57-4c29-b18b-1d8f90c0c21f.png?v=1762997201"},{"product_id":"115-23-3371-1000-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3371 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"115-23-3371 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\"}' data-sheets-root=\"1\"\u003e115-23-3371 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3371 1000 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 1000 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 507.0\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.54\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.60\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e 110\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.79\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.92\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 48.8\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 4240\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 755\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 690\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 1185\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3371\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842783015066,"sku":"115-23-3371","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_07ec95f9-f57c-4d82-997a-1a792024d19e.png?v=1762997201"},{"product_id":"115-23-3372-1250-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3372 1250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"115-23-3372 1250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\"}' data-sheets-root=\"1\"\u003e115-23-3372 1250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3372 1250 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 1250 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 1250 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 633.5\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.75\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.81\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e\u003cspan\u003e 4.33\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 2.13\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 54.1\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 5225\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 845\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 770\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 1350\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3372\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842794549402,"sku":"115-23-3372","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_b7d5b97e-8d92-409d-a54e-7636b58728d6.png?v=1759828117"},{"product_id":"115-23-3373-1500-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-220mils-15kv-power-cable","title":"115-23-3373 1500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-53.pdf?v=1712755559\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"115-23-3373 1500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\"}' data-sheets-root=\"1\"\u003e115-23-3373 1500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 115-23-3373 1500 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis power cable features a 1500 MCM AWG size, which is a large conductor size typically used for high-current applications. The \"1C\" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The \"Okoguard\" is the brand's proprietary insulation material, and \"Okoclear-TP\" refers to the transparent thermoplastic outer jacket. \"MV-105\" indicates that the cable is rated for medium voltage applications up to 15 kV. The \"220mils\" specifies the thickness of the insulation.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as \"15 kV single conductor medium voltage power cable.\"\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eOkoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke\/zero halogen characteristics is needed.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eType MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eMay be installed in cable trays where permitted by NEC Section 392 as permitted by\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhile the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUncoated copper compact stranded per ASTM B-496.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eExtruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e5 mil bare copper tape helically applied, with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMeets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.\u003cbr data-mce-fragment=\"1\"\u003eUL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLow smoke\/zero halogen jacket.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eOkoguard cables meet or exceed all recognized industry standards (UL,\u003cbr data-mce-fragment=\"1\"\u003eNEMA\/ICEA and IEEE).\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e105°C continuous operating temperature.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e140°C emergency rating.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003e250°C short circuit rating\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExcellent corona resistance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to “treeing”.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eScreens are clean stripping.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eExceptional resistance to moisture.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eResistant to most oils, acids, and alkalis.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eUL listed: MV-105, Sunlight Resistant, and Cable Tray Use.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003ePasses the UL \u0026amp; IEEE 383-1974 Vertical Tray Flame Test.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eSizes 500 kcmil and larger pass FT4\/IEEE 1202 Vertical Tray Flame Test.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size AWG:\u003c\/strong\u003e\u003cspan\u003e 1500 MCM\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Conduit Size Inches (5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor Size mm²:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 760.2\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Insulation (in.):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 1.88\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Dia. over Screen (in.):\u003c\/strong\u003e\u003cspan\u003e 1.94\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (Miles):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness (mm):\u003c\/strong\u003e\u003cspan\u003e 4.33\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (Inches):\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 2.26\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. O.D. (mm):\u003c\/strong\u003e\u003cspan\u003e 57.4\u003c\/span\u003e\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Approx. Net Weight:\u003c\/strong\u003e\u003cspan\u003e 6105\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Ampacities (2) Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 925\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (3) Underground Duct:\u003c\/strong\u003e\u003cspan\u003e 845\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Ampacities (4) Cable Tray:\u003c\/strong\u003e\u003cspan\u003e 1500\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Part Number:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan\u003e 115-23-3373\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Okonite","offers":[{"title":"Default Title","offer_id":44842797695130,"sku":"115-23-3373","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_1e99e67e-e3be-4e3a-ba53-8f244b1c02dc.png?v=1759828118"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/okoguard-stranded-uncoated-copper-shield-okoclear-tp-mv-105-15kv-power-cable.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}