{"title":"Multi Conductor Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eMulti Conductor Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"16-awg-2c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"16 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e16 AWG 2C 600V Control Cable, 16 AWG 2C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 16 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 2\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.057\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  25\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.308\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 16\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e 47\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e4.180 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e5.266\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.2\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e673140\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62403989274993,"sku":"NNC673140","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"16-awg-4c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"16 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e16 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e16 AWG 4C 600V Control Cable, 16 AWG 4C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 16 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.057\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  25\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.355\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 32\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e 77\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e4.180 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e5.266\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.4\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSouthwire:\u003c\/strong\u003e \u003cspan data-sheets-root=\"1\"\u003e58028501\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619261\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405419729265,"sku":"NNC619261","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"16-awg-7c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"16 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e16 AWG 7C 600V Control Cable, 16 AWG 7C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 16 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 7\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.057\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  25\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.425\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 56\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  121\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e4.180 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e5.266\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.7\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 42.125px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 160.597px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e604310\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405446533489,"sku":"NNC604310","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-2c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 2C 600V Control Cable, 14 AWG 2C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 2\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.349\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  26\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   68\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.4\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405473075569,"sku":"NNC659874","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-3c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 3C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 3C 600V Control Cable, 14 AWG 3C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 3\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.370\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  38\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   87\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.5\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405499584881,"sku":"NNC659875","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-4c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 4C 600V Control Cable, 14 AWG 4C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.403\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  51\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   109\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e  14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405522030961,"sku":"NNC659876","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-5c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 5C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 5C 600V Control Cable, 14 AWG 5C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 5\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.440\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  64\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  132\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.8\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e  14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405537104241,"sku":"NNC659877","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-6c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 6C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 6C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 6C 600V Control Cable, 14 AWG 6C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 6\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.479\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 77\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  155\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e  14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405556568433,"sku":"NNC659878","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-7c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 7C 600V Control Cable, 14 AWG 7C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 7\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.479\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 90\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  171\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e  12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405558174065,"sku":"NNC659879","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-8c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 8C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 8C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e14 AWG 8C 600V Control Cable, 14 AWG 8C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 8\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.519\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 102\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  195\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.1\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e  12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405559026033,"sku":"NNC659871","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-9c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 9C 600V Control Cable, 14 AWG 9C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 9\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 0.588\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  115\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  236\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.4\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e  12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405573280113,"sku":"NNC659872","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-10c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 10C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 10C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e14 AWG 10C 600V Control Cable, 14 AWG 10C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 10\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.638\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  128\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  266\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405579276657,"sku":"NNC659873","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-12c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 12C 600V Control Cable, 14 AWG 12C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 12\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.659\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 154\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  303\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619930\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405588353393,"sku":"NNC619930","price":8.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-15c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 15C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 15C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 15C 600V Control Cable, 14 AWG 15C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 15\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.730\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 192\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  371\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405594251633,"sku":"NNC619931","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-19c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 19C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 19C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e14 AWG 19C 600V Control Cable, 14 AWG 19C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 0.768\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 243\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  446\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  3.1\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405598577009,"sku":"NNC619932","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-20c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 20C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 20C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 20C 600V Control Cable, 14 AWG 20C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eStandards:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 20\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.808\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 256\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  475\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  3.2\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405600182641,"sku":"NNC619934","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-25c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 25C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 25C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e14 AWG 25C 600V Control Cable, 14 AWG 25C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eStandards:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 25\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.937\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 320\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  619\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 3.7\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405602607473,"sku":"NNC619935","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-30c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 30C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 30C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e14 AWG 30C 600V Control Cable, 14 AWG 30C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 30\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.991\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 384\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  719\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 4.0\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405602738545,"sku":"NNC619938","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"14-awg-37c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"14 AWG 37C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 37C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e14 AWG 37C 600V Control Cable, 14 AWG 37C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 14 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e 0.070\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  1.067\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 474\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   862\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e2.630 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e3.288\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 5.3\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e10\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405603197297,"sku":"NNC619939","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-2c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 2C 600V Control Cable, 12 AWG 2C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 2\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.384\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  41\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e    90\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e1.660 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.5\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e604305\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405603426673,"sku":"NNC606672","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-2c-copper-fr-xlpe-cpe-jacket-control-cable-600v-1","title":"12 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 2C 600V Control Cable, 12 AWG 2C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 2\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.398\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  41\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  103\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e1.660 \u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405614502257,"sku":"NNC604305","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-3c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 3C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 3C 600V Control Cable, 12 AWG 3C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 2\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.408\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  41\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  61\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405620302193,"sku":"NNC658927","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-4c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 4C 600V Control Cable, 12 AWG 4C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eStandards:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.445\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  81\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e 148\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.8\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e616890\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405620924785,"sku":"NNC616890","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-4c-copper-fr-xlpe-cpe-jacket-control-cable-600v-1","title":"12 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 4C 600V Control Cable, 12 AWG 4C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.461\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  81\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  155\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.8\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e604307\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405622694257,"sku":"NNC604307","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-5c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 5C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 5C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 5C 600V Control Cable, 12 AWG 5C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 5\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.487\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 102\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  181\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  1.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405623284081,"sku":"NNC625874","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-6c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 6C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 6C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 6C 600V Control Cable, 12 AWG 6C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 6\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.532\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 122\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   214\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.1\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405639045489,"sku":"NNC625478","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-7c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e12 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 7C 600V Control Cable, 12 AWG 7C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 7\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.532\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 143\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  237\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.1\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619937\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405641339249,"sku":"NNC619937","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-8c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 8C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 8C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 8C 600V Control Cable, 12 AWG 8C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 8\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e    0.607\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 163\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  288\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.4\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405642060145,"sku":"NNC622144","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-9c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 9C 600V Control Cable, 12 AWG 9C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 9\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.651\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 183\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  324\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619939\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405643862385,"sku":"NNC619939","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-10c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 10C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 10C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 10C 600V Control Cable, 12 AWG 10C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 10\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.709\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 204\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  365\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.8\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405644353905,"sku":"NNC655887","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-12c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 12C 600V Control Cable, 12 AWG 12C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 12\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.732\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 244\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  419\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  2.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618414\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405644910961,"sku":"NNC618414","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-15c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 15C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 15C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 15C 600V Control Cable, 12 AWG 15C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 15\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.813\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 305\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  516\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  3.3\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405646385521,"sku":"NNC618415","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-19c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 19C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 19C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 19C 600V Control Cable, 12 AWG 19C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.896\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e 387\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  657\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  3.6\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405648449905,"sku":"NNC618412","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-20c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 20C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 20C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 20C 600V Control Cable, 12 AWG 20C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 20\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 0.942\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  407\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e 699\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  3.8\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:   \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e15\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405649269105,"sku":"NNC618418","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-25c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 25C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 25C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 25C 600V Control Cable, 12 AWG 25C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 25\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 1.043\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  509\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e 860\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  5.2\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e13\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405657297265,"sku":"NNC618411","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-30c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 30C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 30C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e12 AWG 30C 600V Control Cable, 12 AWG 30C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 30\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  1.104\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  611\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  1005\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  5.5\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e11\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e13\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405660377457,"sku":"NNC618419","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"12-awg-37c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"12 AWG 37C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 37C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e12 AWG 37C 600V Control Cable, 12 AWG 37C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.087\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  1.191\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  753\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  1211\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft:  \u003c\/b\u003e118\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e2.075\u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e  6.0\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e12\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405672796529,"sku":"NNC618416","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-2c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 2C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e10 AWG 2C 600V Control Cable, 10 AWG 2C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 2\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.431\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  65\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  124\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 1.7\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 30\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e30\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e30\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619943\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405674500465,"sku":"NNC619943","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-3c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 3C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 3C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 3C 600V Control Cable, 10 AWG 3C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 3\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.459\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  97\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  165\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 1.8\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 30\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e30\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e30\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618360\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405675811185,"sku":"NNC618360","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-4c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e10 AWG 4C 600V Control Cable, 10 AWG 4C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 0.511\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  130\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  205\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.1\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e30\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e604302\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405681348977,"sku":"NNC619945","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-4c-copper-fr-xlpe-cpe-jacket-control-cable-600v-1","title":"10 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e10 AWG 4C 600V Control Cable, 10 AWG 4C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 45\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 0.516\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  130\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  206\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.1\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e30\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619945\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405768315249,"sku":"NNC604302","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-5c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 5C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 5C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e10 AWG 5C 600V Control Cable, 10 AWG 5C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 5\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e 0.581\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e   162\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  273\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.3\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e30\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405802721649,"sku":"NNC632258","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-6c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 6C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 6C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 6C 600V Control Cable, 10 AWG 6C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 6\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.632\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  194\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  323\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.5\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:  \u003c\/strong\u003e28\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e30\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405812781425,"sku":"NNC665588","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-7c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 7C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 7C 600V Control Cable, 10 AWG 7C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 7\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.641\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  227\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  356\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.5\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 21\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e28\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e604219\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405813633393,"sku":"NNC604219","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-8c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 8C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 8C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 8C 600V Control Cable, 10 AWG 8C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 8\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.685\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e   259\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  410\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.7\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 21\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e28\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405814944113,"sku":"NNC569845","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-9c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 9C 600V Control Cable, 10 AWG 9C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 9\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.736\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e   291\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e  461\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 2.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 21\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e28\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619950\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405820186993,"sku":"NNC619950","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-10c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 10C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 10C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 10C 600V Control Cable, 10 AWG 10C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 10\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e  0.803\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e    324\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   519\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 3.2\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405821235569,"sku":"NNC586947","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-12c-copper-fr-xlpe-cpe-jacket-control-cable-600v","title":"10 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-end=\"179\" data-start=\"157\"\u003e10 AWG 12C 600V Control Cable, 10 AWG 12C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 12\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.830\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e   389\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   600\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 3.3\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e622897\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405827592561,"sku":"NNC622897","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-12c-copper-fr-xlpe-cpe-jacket-control-cable-600v-1","title":"10 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 12C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e10 AWG 12C 600V Control Cable, 10 AWG 12C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 12\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 60\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.887\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e   389\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e    615\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 3.5\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 65.5875px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 42.125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 42.125px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4625px;\"\u003e\n\u003ctd style=\"width: 160.597px; height: 23.4625px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px; height: 23.4625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e604304\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405827985777,"sku":"NNC604304","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"},{"product_id":"10-awg-15c-copper-fr-xlpe-cpe-jacket-control-cable-600v-1","title":"10 AWG 15C Copper FR-XLPE CPE Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85010_1_303b9389-395b-45dc-9a9d-ebb0805199f8.pdf?v=1759403467\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 15C Copper FR-XLPE CPE Jacket Control Cable 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-start=\"157\" data-end=\"179\"\u003e10 AWG 15C 600V Control Cable, 10 AWG 15C FR-XLPE Insulated Control Cable, 16\/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE\/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor: \u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation: \u003cbr\u003e\u003c\/b\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller: \u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder: \u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket: \u003cbr\u003e\u003c\/b\u003eChlorinated Polyethylene (CPE) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size:\u003c\/b\u003e 10 AWG \u003cbr\u003e\u003cb\u003e• Number of Conductors:\u003c\/b\u003e 15\u003cbr\u003e\u003cb\u003e• Diameter Over Conductor\u003c\/b\u003e \u003cb\u003e(inch):\u003c\/b\u003e  0.111\u003cbr\u003e\u003cb\u003e• Insulation Thickness (Mil):\u003c\/b\u003e  30\u003cbr\u003e\u003cb\u003e• Jacket Thickness (Mil):\u003c\/b\u003e 80\u003cbr\u003e\u003cb\u003e• Approx. OD (In):\u003c\/b\u003e   0.964\u003cbr\u003e\u003cb\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/b\u003e  486\u003cbr\u003e\u003cb\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/b\u003e   777\u003cbr\u003e\u003cb\u003e• DC Resistance Ω \/1000ft: \u003c\/b\u003e 1.040\u003cbr\u003e\u003cb\u003e• AC Resistance @ 90°C Ω \/1000ft:  \u003c\/b\u003e1.300 \u003cbr\u003e\u003cb\u003e• Min Bending Radius (In):\u003c\/b\u003e 3.9\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity At 60°C:  \u003c\/strong\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 75°C:   \u003c\/strong\u003e17\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:  \u003c\/strong\u003e20\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62405829886321,"sku":"NNC604306","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_22baf9a1-c3fc-4d74-b836-6ae09fb14dec.png?v=1754981831"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/multi-conductor-copper-fr-xlpe-cpe-jacket-control-cable-600v.oembed?page=3","provider":"NassauNationalCable","version":"1.0","type":"link"}