12-3C Solid Copper MC-Stat Plus Aluminum THHN Insulation Interlocked Armored Cable
![12-3C Solid Copper MC-Stat Plus Aluminum THHN Insulation Interlocked Armored Cable](http://nassaunationalcable.com/cdn/shop/products/Untitled110_ab80a62d-2b65-4e24-9066-42c5cf754ea6_{width}x.png?v=1642416581)
Where are we? 4 Continents 8 Countries
![map](http://nassaunationalcable.com/cdn/shop/t/125/assets/MapDesign1.png?v=141730508087340066881694327314)
![garrie](http://nassaunationalcable.com/cdn/shop/t/125/assets/garrie11.png?v=147058525823915106791694327288)
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Allowable Ampacity for 12-3C Solid Copper MC-Stat Plus Aluminum THHN Insulation Interlocked Armored Cable: 100 Amps
Applications:
Branch circuit wiring for various power distribution systems, including lighting, devices, and receptacles. Suitable for branch circuits supplying computers and other electronic equipment where additive harmonic currents from nonlinear switching loads may be present.
Also Known as:
AFC Cable, MC Cable, MC Stat Plus, Interlocked Armored, Interlocked Aluminum, Aluminum Cable, MCI-A Cable, Galvanized Interlocking, Aluminum Strip Cable, 120/208V Cable
Construction:
• Armor: Interlocked Aluminum Strip (Light Green Striped)
• Conductors: Solid Copper
• Conductor Insulation: Type THHN with Protective Polypropylene Covering on Each Insulated Conductor (No Assembly Tape)
• Neutral Conductor: White 120/208V
• Grounding: Two grounding means – (1) armor PLUS full-sized aluminum ground conductor, (2) Full-sized green insulated copper grounding conductor NEC® 250.118(10)(b)
• Maximum Temperature Rating: 90°C (Dry)
• Maximum Voltage Rating: 600V
Features & Benefits:
• A neutral per phase Type MCI-A cable designed for multi-wire branch circuit applications
• Addresses harmonics distortions in power distribution systems and meets the requirements of NEC 210.4(B) Disconnecting Means
• Eliminates shared neutrals and allows electrical systems to continue to operate
Decreases the time it takes to identify a faulty circuit because only the affected single-phase breaker will trip thus, reducing the length of unnecessary outages
• Type MCI-A cable with a green insulated copper grounding conductor
• Made in USA of US and/or imported materials
References & Ratings:
• UL 1569, UL 83, UL 1479, UL 1581, UL 2556, E80042
• Federal spec A-A–59544 (formerly J-C–30B)
• NEC 210.4(B), 330, 300.22(C), 230.43, 250.118, 392, 396, 503, 530, 517, 518, 530, 645
• May be surface mounted, fished, and/or embedded in plaster
• UL Classified 1, 2, and 3 hours through (Fire) penetration product, R–14141
• NEC 300.22(C) Environmental Air Handling Spaces
• Cable Tray Rated, install per NEC
• Meets all OSHA and HUD requirements
• Patent Pending
• Made in USA of US and/or imported materials
Specification:
• Phase AWG Size: 12
• Number of Conductors: 3
• Neutral AWG Size: 12
• Number of Conductors: 3
• Insulated Grounding Wire AWG: 12 (Solid Green)
• Bonding/Bond Cond. AWG: 10
• Armor Nominal O.D: 0.663 Inch
• Weight 1000ft: 258 Lbs
• (Black / Red / Blue) 1000' Reel Code: 7305-60-00
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews