{"title":"Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003ch2\u003e\u003cspan\u003eMachine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"machine-flex-thhn-thwn-2-copper-pvc-power-wire-1","title":"Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMachine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eMachine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64078902034801,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"8-awg-168-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"8 AWG 168 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e8 AWG 168 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e8 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 8 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 8 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  8 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  168\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.153\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  35\u003cbr\u003e\u003cstrong\u003e• Insulation Color : \u003c\/strong\u003eBK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.223\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft : \u003c\/strong\u003e52\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e62\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e0.8\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e132\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.715\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e 0.861\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.052\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  :  \u003c\/strong\u003e50\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e55\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64078917632369,"sku":"NNC525876","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"6-awg-273-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"6 AWG 273 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e6 AWG 273 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e6 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 6 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 6 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  6 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 273\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.190\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  35\u003cbr\u003e\u003cstrong\u003e• Insulation Color : \u003c\/strong\u003eBK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.264\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft :  \u003c\/strong\u003e83\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e98\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch :  \u003c\/strong\u003e1.0\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e209\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.450\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e 0.541\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.051\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  :   \u003c\/strong\u003e65\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e75\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64078926446961,"sku":"NNC659874","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"4-awg-413-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"4 AWG 413 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e4 AWG 413 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e4 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 4 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 4 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  4 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 413\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.235\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  50\u003cbr\u003e\u003cstrong\u003e• Insulation Color : \u003c\/strong\u003eBK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.335\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft :  \u003c\/strong\u003e130\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e153\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e1.3\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e333\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.282\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e 0.340\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.048\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e95\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64078929101169,"sku":"NNC672867","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"3-awg-525-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"3 AWG 525 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e3 AWG 525 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e3 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 3 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 3 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  4 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 525\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.270\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  50\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e GN\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.366\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft : \u003c\/strong\u003e169\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e197\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e1.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e420\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.226\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e 0.272\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.047\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 100\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e115\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64078933459313,"sku":"NNC664229","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"2-awg-665-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"2 AWG 665 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e2 AWG 665 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 2 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 2 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  2 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 665\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.302\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  50\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e BK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  0.402\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft : \u003c\/strong\u003e210\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e243\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e1.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e530\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:   \u003c\/strong\u003e0.179\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e 0.216\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.045\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e130\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64078981005681,"sku":"NNC584234","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"1-awg-836-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"1 AWG 836 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e1 AWG 836 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 1 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 1 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  1 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 836\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.329\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e GN\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e   0.449\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft : \u003c\/strong\u003e260\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e302\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e1.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e669\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:   \u003c\/strong\u003e0.137\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e  0.164\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.046\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 130\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e145\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64079007613297,"sku":"NNC456258","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"1-0-awg-1044-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"1\/0 AWG 1044 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e1\/0 AWG 1044 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 1\/0 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 1\/0 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  1\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 1044\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch : \u003c\/strong\u003e0.400\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e BK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.520\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft :  \u003c\/strong\u003e334\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e374\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e 2.0\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e844\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.113\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e  0.136\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.044\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 150\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e170\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64079009677681,"sku":"NNC677368","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"2-0-awg-1330-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"2\/0 AWG 1330 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e2\/0 AWG 1330 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 2\/0 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 2\/0 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  2\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 1330\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.430\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e BK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.520\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft :   \u003c\/strong\u003e381\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e426\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e 2.0\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e1064\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.090\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e  0.108\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e0.043\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 175\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e195\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64079011938673,"sku":"NNC865924","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"3-0-awg-1672-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"3\/0 AWG 1672 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e3\/0 AWG 1672 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 3\/0 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 3\/0 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  3\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  1672\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.490\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e BK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  0.608\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft :  \u003c\/strong\u003e535\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e599\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e 2.4\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e1342\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.072\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e  0.087\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e 0.042\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 200\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e225\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64079048606065,"sku":"NNC457120","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"},{"product_id":"4-0-awg-2109-strands-machine-flex-thhn-thwn-2-copper-pvc-power-wire","title":"4\/0 AWG 2109 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44066_1.pdf?v=1781846850\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e4\/0 AWG 2109 Strands Machine Flex THHN\/THWN-2 Copper PVC Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s Machine Flex power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. 1\/0 AWG \u0026amp; larger rated for CT use Flame Resistant. 90°C Wet or Dry. 600 Volts. Flexible Stranded Copper Conductor. PVC Insulation and Nylon Jacket (THHN\/THWN-2). Oil \u0026amp; Gasoline Resistant. Sunlight Resistant. Rated UL VW-1 and CSA FT1 \u0026amp; FT4 Flame Resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Machine Flex THHN\/THWN-2 Power Cable Flexible THHN\/THWN-2 Copper Power Wire THHN\/THWN-2 Machine Tool Wire Flexible Copper PVC\/Nylon Power Cable Industrial Machine Flex Power Cable 4\/0 AWG Flexible Stranded Copper THHN Wire THHN\/THWN-2 Industrial Power Wire 600V Machine Flex Copper Cable PVC Insulated Nylon Jacket Power Wire Flexible Control \u0026amp; Power Wire 4\/0 AWG Machine Wiring THHN\/THWN-2 Cable Industrial Equipment Power Cable Flexible Feed Wire for Machinery Copper Machine Power Conductor\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having    Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 83 Thermoplastic Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 2463 (80C, 600V)\u003cbr\u003e• UL 1063 Machine Tool Wiring (MTW)\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 - 4\/0 AWG: Class K, flexible stranded bare copper. 250 - 750 kcmil: Class I, flexible stranded bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Polyvinyl Chloride (PVC) with Nylon sheath \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  4\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e   2109\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.550\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Insulation Color :\u003c\/strong\u003e BK\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  0.664\u003cbr\u003e\u003cstrong\u003e• Copper Weight  lb\/1000ft :  \u003c\/strong\u003e676\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e746\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius inch : \u003c\/strong\u003e 2.6\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb : \u003c\/strong\u003e1692\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.057\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 75°C :\u003c\/strong\u003e  0.069\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ 60Hz : \u003c\/strong\u003e 0.041\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e 230\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e260\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64079051522417,"sku":"NNC679607","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_5_9acaaec2-c077-43cc-98ef-cec08312e4e8.png?v=1781846283"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/machine-flex-thhn-thwn-2-copper-pvc-power-wire.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}