{"title":"JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"","products":[{"product_id":"3-cores-10-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 10 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 10 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 10 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)SPYCB Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 10 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.35 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 4.05 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 34.1 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.840 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.1424 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39755954749594,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_9e53ad3d-4caf-41ce-8a51-723c20d3b022.png?v=1762483781"},{"product_id":"3-cores-16-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 16 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 16 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 16 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 16 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.70 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 5.10 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 36.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.5 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.160 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.3545 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756226789530,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_a73f8956-fc5a-4498-9d17-89250497c8aa.png?v=1762483782"},{"product_id":"3-cores-25-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 25 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 25 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 25 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 25 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 6.42 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 39.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.734 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.6716 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756456624282,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_f139d219-3d86-4024-900c-bf380068a9e2.png?v=1759812863"},{"product_id":"3-cores-35-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 35 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 35 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 35 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 35 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 7.56 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 42.2 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.529 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.9751 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756547162266,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_a526b7ea-6adb-486e-ab08-b839897d86c9.png?v=1762483784"},{"product_id":"3-cores-50-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 50 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 50 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 50 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 50 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/1.78 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 8.90 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 45.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.7 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.391 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.3699 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756594544794,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_7cef7914-f967-4b26-832a-40c49b9157ef.png?v=1762483784"},{"product_id":"3-cores-70-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 70 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 70 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 70 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 70 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 10.70 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 49.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.8 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.270 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.9694 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756630720666,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_b9ad18e2-47c6-440d-9dda-ce90129bead0.png?v=1759812864"},{"product_id":"3-cores-95-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 95 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 95 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 95 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 95 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 12.60 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 54.1 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 1.9 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.195 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 3.7107 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756661293210,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_f712639f-415b-43bd-8757-6eeeed3cf2a6.png?v=1762483785"},{"product_id":"3-cores-120-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 120 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 120 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 120 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 120 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.03 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 14.21 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 57.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 2.0 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.154 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 4.3806 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756910067866,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_cde161d3-e255-40cc-9f1e-891ecf4eff3b.png?v=1762483786"},{"product_id":"3-cores-150-mm-jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 150 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 150 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 150 mm² JIS C 3410 6\/10KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYC Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 150 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 15.75 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 61.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e : 2.1 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.126 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 5.1146 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39756997558426,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_d4de33d0-49fb-4f8a-9b84-4b40ef40feb8.png?v=1759812866"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/jis-c-3410-6-10kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}