{"title":"JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"","products":[{"product_id":"1-cores-16-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 16 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 16 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 16 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 16 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.70 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 5.10 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 20.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 0.8 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.160 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.5397 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727544008858,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_3176a372-0e9d-4f89-aa40-56db252ee757.png?v=1759812786"},{"product_id":"1-cores-25-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 25 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 25 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 25 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 25 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 6.42 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 22.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 0.9 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.734 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.6420 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769702236314,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_1c415962-5120-4237-827b-8e7e3933d470.png?v=1759812888"},{"product_id":"1-cores-35-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 35 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 35 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 35 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e• Code\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 35 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 7.56 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 23.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 0.9 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.529 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.7478 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769706201242,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_fd062058-b94b-437f-b589-b0337fa94679.png?v=1759812888"},{"product_id":"1-cores-50-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 50 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 50 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 50 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 50 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/1.78 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 8.90 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 24.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.0 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.391 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.8678 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769715245210,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_63236b73-8e80-4018-8da1-15952d27d893.png?v=1762483882"},{"product_id":"1-cores-70-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 70 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 70 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 70 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 70 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 10.70 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 26.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.1 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.270 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.0653 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769739002010,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_bc156f41-dd8f-4735-a7cb-2983461aa8f1.png?v=1759812890"},{"product_id":"1-cores-95-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 95 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 95 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 95 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 95 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e :19\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 12.60 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 28.9 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.2 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.195 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.3053 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769747390618,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11.png?v=1762483884"},{"product_id":"1-cores-120-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 120 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 120 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 120 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 120 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.03 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 14.21 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 30.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.2 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.154 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.5169 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769757778074,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_44d0b047-b3d6-443c-8edf-507f874d5eb2.png?v=1762483884"},{"product_id":"1-cores-150-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 150 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 150 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 150 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 150 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.25 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 15.75 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 32.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.3 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.126 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.8415 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769759449242,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_51eea971-2d1e-42e3-9ef7-7fa1876cb3b0.png?v=1762483885"},{"product_id":"1-cores-185-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 185 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 185 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 185 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 185 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e• Conductor Dia.\u003c\/strong\u003e : 17.64 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 34.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.100 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.1590 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769767542938,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_ea5ee2d6-ea5e-47d4-8616-809f0422b1ec.png?v=1759812890"},{"product_id":"1-cores-240-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 240 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 240 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 240 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 240 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 61\/2.25 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 20.25 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 37.7 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.5 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.0762 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.6529 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769774522522,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_a9d0730f-11d7-4119-9cb7-0ea87349d091.png?v=1762483887"},{"product_id":"1-cores-300-mm-jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 300 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 300 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 300 mm² JIS C 3410 6\/10KV (FA-)SPYCB Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCB Cable, MV Cable, Marine Shipyard Cable, Japenese Industrial Cable, Flame Retardant Cable, Medium Voltage Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 300 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 61\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 22.68 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Nominal Overall Dia.\u003c\/strong\u003e : 40.3 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCB Tolerance\u003c\/strong\u003e : 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.0607 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 3.1539 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39769779962010,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/aa11_9c76568d-92da-48f6-a646-cd207cdbc8ca.png?v=1759812891"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/jis-c-3410-6-10kv-fa-spycb-shipboard-flame-retardant-medium-voltage-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}