{"title":"JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cstrong\u003e﻿\u003c\/strong\u003e\u003c\/strong\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":771,\"3\":{\"1\":0},\"4\":{\"1\":2,\"2\":65535},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}'\u003eJIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e","products":[{"product_id":"3-cores-10-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 10 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e3 Cores 10 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 10 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 10 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.35 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 4.05 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 34.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.4 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.840 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 1.1429 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727440724122,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_c36345e5-dbfd-4279-acce-510316bcfe04.png?v=1759812786"},{"product_id":"3-cores-16-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstrong\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"3 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}' data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}'\u003e3 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 16 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.70 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 5.10 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 36.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.5 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.160 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 1.3546 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727477260442,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_a0f71e9a-fb47-4431-a436-3ecf807b3b74.png?v=1762483607"},{"product_id":"3-cores-25-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cabl3","title":"3 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cabl3","description":"\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"3 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cabl3\"}'\u003e3 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 25 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 6.42  mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 39.6 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.734 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 1.6721 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727522283674,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_65426e73-da81-4769-b25c-23d0088a623d.png?v=1762483609"},{"product_id":"3-cores-35-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"3 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}' data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}'\u003e3 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 35 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 7.56 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 42.2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.529 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 1.9756 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727547121818,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_c297b091-fafa-45f7-b892-b414cdb88858.png?v=1759812788"},{"product_id":"3-cores-50-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"3 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}'\u003e3 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 50 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/1.78 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 8.90 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 45.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.7 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.391 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 2.3707 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727583723674,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_fe4ff77e-31cb-400b-9b3c-9b11913de85a.png?v=1762483611"},{"product_id":"3-cores-70-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"3 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}'\u003e3 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 70 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 10.70 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 49.6 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.8 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.270 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 2.9703 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cquillbot-extension-portal\u003e\u003c\/quillbot-extension-portal\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727661645978,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_12ad0a83-f847-4bc6-994c-8e5ede8af485.png?v=1762483611"},{"product_id":"3-cores-95-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"3 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}'\u003e3 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cstrong\u003e﻿\u003c\/strong\u003e\u003c\/strong\u003e  \u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 95 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 12.60 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 54.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 1.9 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.195 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 3.7112 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727694315674,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_b10ca934-f304-46de-8539-f27b6ed1aab3.png?v=1762483613"},{"product_id":"3-cores-120-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cstrong\u003e﻿\u003c\/strong\u003e\u003c\/strong\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstrong\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"3 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}' data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}'\u003e3 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cstrong\u003e﻿\u003c\/strong\u003e\u003c\/strong\u003e  \u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eShipboard Cable,\u003c\/span\u003e\u003cspan\u003e JIS C 3410 Cable, \u003c\/span\u003e\u003cspan\u003eTPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 120 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.03 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 14.21 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 57.8 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 2.0 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.154 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 4.3815 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727719121050,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_6c668b7c-ae9a-4bda-8357-e7e906463b40.png?v=1762483613"},{"product_id":"3-cores-150-mm-jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cstrong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstrong\u003e\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"3 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\"}'\u003e3 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)TPYC Shipboard Flame Retardant Medium Voltage Cable: \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide: JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact: CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature: 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, TPYC Cable, Asian Shipyard Cable, Flame Retardant Cable, Tinned Annealed Copper, Medium Voltage Cable, Japenese Industrial Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e: Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e: Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e: Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e: Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e: Red, Yellow, Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e: 150 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 15.75 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Nominal Overall Dia.\u003c\/strong\u003e : 61.6 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYC Tolerance\u003c\/strong\u003e: 2.1 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.126 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e: 5.1153 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727756607642,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/true_74d0b252-88b8-4655-b887-710cbf7e6f3f.png?v=1762483614"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/jis-c-3410-3-6-6kv-fa-tpyc-shipboard-flame-retardant-medium-voltage-cable-1.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}