{"title":"JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"","products":[{"product_id":"1-cores-10-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 10 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 10 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 10 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 10 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.35 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 4.05 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 19.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 0.8 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.840 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.4515 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39719614546074,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_56148dc2-ba29-4e23-a84b-66ece2eac801.png?v=1762483565"},{"product_id":"1-cores-16-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 16 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 16 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.70 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 5.10 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 21.2 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 0.8 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.160 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.5327 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39719640629402,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_c59851c2-918c-4fc3-ad0c-4f86780a528a.png?v=1762483566"},{"product_id":"1-cores-25-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 25 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e• 3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 25 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 6.42 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 22.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 0.9 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.734 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.6315 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39719659208858,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_8692bee7-8abe-4cf3-8c64-ffe79157a584.png?v=1759812766"},{"product_id":"1-cores-35-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 35 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 35 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 7.56 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 23.9 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.0 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.529 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.7408 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39719690371226,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_a3e5c276-f60f-46ed-9b50-c4423e253324.png?v=1762483568"},{"product_id":"1-cores-50-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 50 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 50 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/1.78 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 8.90 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 25.4 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.0 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.391 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 0.8678 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39719732740250,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_50385d1b-202f-4559-943d-eedcd325a6be.png?v=1759812766"},{"product_id":"1-cores-70-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 70 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 70 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 10.70 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 27.4 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.1 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.270 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.0724 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39719763968154,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_01e80b23-5138-4181-af72-cc305b2f3664.png?v=1762483569"},{"product_id":"1-cores-95-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 95 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 95 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 12.60 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 29.7 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.2 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.195 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.3193 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39726736900250,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_217b55cf-5302-4e3c-b552-de4a2094b9be.png?v=1762483597"},{"product_id":"1-cores-120-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 120 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 120 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.03 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 14.21 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 31.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.3 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.154 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.5380 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727267971226,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_43091eb8-2367-49d2-a385-cce64e60d696.png?v=1759812783"},{"product_id":"1-cores-150-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 150 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 150 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.25 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 15.75 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 33.3 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.3 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.126 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.7780 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727298936986,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_90dd451b-cc85-4bca-8441-890206e562d3.png?v=1762483603"},{"product_id":"1-cores-185-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 185 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 185 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 185 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 185 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 17.64 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 35.8 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.100 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.1801 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727315550362,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_988258cd-ca8a-4865-9f9c-ae0432adb185.png?v=1759812785"},{"product_id":"1-cores-240-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 240 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 240 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 240 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 240 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 61\/2.25 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 20.25 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 39.3 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.0762 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.7023 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727356182682,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_797128aa-2cad-429c-bf9b-9bfe009ad7cb.png?v=1762483606"},{"product_id":"1-cores-300-mm-jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable","title":"1 Cores 300 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e1 Cores 300 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 1 Cores 300 mm² JIS C 3410 3.6\/6KV (FA-)SPYCBY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Cold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 Cable, SPYCBY Cable, Asian Shipyard Cable, Flame Retardant Cable, Medium Voltage Cable, Japenese Industrial Cable, Marine Shipyard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003e• Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• A Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003e• EPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Three Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003e• Flame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003e• Suitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003e• In Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003e• Any Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 300 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 61\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 22.68 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Nominal Overall Dia.\u003c\/strong\u003e : 42.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003e(FA-)SPYCBY Tolerance\u003c\/strong\u003e : 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.0607 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight\u003c\/strong\u003e : 3.2526 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39727405039770,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/1aSPYCB_429d70c7-a5d3-4543-bc68-1ccc57ddb682.png?v=1759812785"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/jis-c-3410-3-6-6kv-fa-spycby-shipboard-flame-retardant-medium-voltage-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}