{"title":"Instrumentation Tray Cable PLTC\/ITC Individual \u0026 Overall Shield PVC Jacket 300V 105°C","description":"","products":[{"product_id":"20-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/2 Cable Tray, 20\/2 Cable Tray Types, 20\/2 Electrical Cable Tray, 20\/2 Pvc Cable Tray, 20\/2 wire cable tray, 20\/2 cable tray wire, 20\/2 PLTC Cable, 20\/2 ITC Cable, 20\/2 PVC Cable, 20\/2 Tray Instrument Cable, 20\/2 Tray Instrumentation Cable, 20\/2 SPOS Cable, 20\/2 Low-Voltage Tray Cable, 20\/2 Shielded Tray Cable, 20\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.349 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 66 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31439908241508,"sku":"NNC33610X","price":1.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_300ec0d6-50f5-4ff3-868f-a07b50e8e0ac.jpg?v=1762478512"},{"product_id":"20-awg-4p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 4P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 4P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/4 Cable Tray, 20\/4 Cable Tray Types, 20\/4 Electrical Cable Tray, 20\/4 Pvc Cable Tray, 20\/4 wire cable tray, 20\/4 cable tray wire, 20\/4 PLTC Cable, 20\/4 ITC Cable, 20\/4 PVC Cable, 20\/4 Tray Instrument Cable, 20\/4 Tray Instrumentation Cable, 20\/4 SPOS Cable, 20\/4 Low-Voltage Tray Cable, 20\/4 Shielded Tray Cable, 20\/4 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.423 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 101 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-04PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31439917940836,"sku":"NNC33611X","price":1.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_ac28b62a-0b67-45f1-b9e2-8c73f71ab54d.jpg?v=1762478513"},{"product_id":"20-awg-8p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 8P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 8P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/8 Cable Tray, 20\/8 Cable Tray Types, 20\/8 Electrical Cable Tray, 20\/8 Pvc Cable Tray, 20\/8 wire cable tray, 20\/8 cable tray wire, 20\/8 PLTC Cable, 20\/8 ITC Cable, 20\/8 PVC Cable, 20\/8 Tray Instrument Cable, 20\/8 Tray Instrumentation Cable, 20\/8 SPOS Cable, 20\/8 Low-Voltage Tray Cable, 20\/8 Shielded Tray Cable, 20\/8 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.543 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 170 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-08PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31439955951716,"sku":"NNC33612X","price":2.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_dddd471d-2e63-4af8-938b-2999f20f81b4.jpg?v=1762478514"},{"product_id":"20-awg-12p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 12P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 12P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/12 Cable Tray, 20\/12 Cable Tray Types, 20\/12 Electrical Cable Tray, 20\/12 Pvc Cable Tray, 20\/12 wire cable tray, 20\/12 cable tray wire, 20\/12 PLTC Cable, 20\/12 ITC Cable, 20\/12 PVC Cable, 20\/12 Tray Instrument Cable, 20\/12 Tray Instrumentation Cable, 20\/12 SPOS Cable, 20\/12 Low-Voltage Tray Cable, 20\/12 Shielded Tray Cable, 20\/12 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.674 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 250 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-12PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31439966994532,"sku":"NNC33613X","price":2.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_b250ae51-e810-4c46-86b2-b581c7aaf69f.jpg?v=1762478515"},{"product_id":"20-16-pairs-individual-overall-shield-pltc-pvc-cable-300v","title":"20 AWG 16P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 16P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/16 Cable Tray, 20\/16 Cable Tray Types, 20\/16 Electrical Cable Tray, 20\/16 Pvc Cable Tray, 20\/16 wire cable tray, 20\/16 cable tray wire, 20\/16 PLTC Cable, 20\/16 ITC Cable, 20\/16 PVC Cable, 20\/16 Tray Instrument Cable, 20\/16 Tray Instrumentation Cable, 20\/16 SPOS Cable, 20\/16 Low-Voltage Tray Cable, 20\/16 Shielded Tray Cable, 20\/16 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.747 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 315 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-16PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31439974596708,"sku":"NNC33614X","price":3.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_3ff493c9-2da6-45b4-98b8-b31fe3388a8c.jpg?v=1762478515"},{"product_id":"20-awg-20p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 20P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 20P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/20 Cable Tray, 20\/20 Cable Tray Types, 20\/20 Electrical Cable Tray, 20\/20 Pvc Cable Tray, 20\/20 wire cable tray, 20\/20 cable tray wire, 20\/20 PLTC Cable, 20\/20 ITC Cable, 20\/20 PVC Cable, 20\/20 Tray Instrument Cable, 20\/20 Tray Instrumentation Cable, 20\/20 SPOS Cable, 20\/20 Low-Voltage Tray Cable, 20\/20 Shielded Tray Cable, 20\/20 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.827 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 382 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-20PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440022962276,"sku":"NNC33615X","price":4.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_15a237b4-8647-4de8-9260-2dc46f4183f7.jpg?v=1762478516"},{"product_id":"20-awg-24p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 24P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 24P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/24 Cable Tray, 20\/24 Cable Tray Types, 20\/24 Electrical Cable Tray, 20\/24 Pvc Cable Tray, 20\/24 wire cable tray, 20\/24 cable tray wire, 20\/24 PLTC Cable, 20\/24 ITC Cable, 20\/24 PVC Cable, 20\/24 Tray Instrument Cable, 20\/24 Tray Instrumentation Cable, 20\/24 STOS Cable, 20\/24 Low-Voltage Tray Cable, 20\/24 Shielded Tray Cable, 20\/24 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.939 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 466 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-24PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440057860196,"sku":"NNC33616X","price":5.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_8d28a72b-b727-4e58-83a0-fa9387c7b75e.jpg?v=1762478516"},{"product_id":"20-awg-36p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 36P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 36P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/36 Cable Tray, 20\/36 Cable Tray Types, 20\/36 Electrical Cable Tray, 20\/36 Pvc Cable Tray, 20\/36 wire cable tray, 20\/36 cable tray wire, 20\/36 PLTC Cable, 20\/36 ITC Cable, 20\/36 PVC Cable, 20\/36 Tray Instrument Cable, 20\/36 Tray Instrumentation Cable, 20\/36 SPOS Cable, 20\/36 Low-Voltage Tray Cable, 20\/36 Shielded Tray Cable, 20\/36 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 36\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.070 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 655 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-36PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440073719908,"sku":"NNC33617X","price":7.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_68889599-f0ac-4488-aaac-9c62e10fd17b.jpg?v=1762478518"},{"product_id":"20-awg-50p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"20 AWG 50P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 50P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/50 Cable Tray, 20\/50 Cable Tray Types, 20\/50 Electrical Cable Tray, 20\/50 Pvc Cable Tray, 20\/50 wire cable tray, 20\/50 cable tray wire, 20\/50 PLTC Cable, 20\/50 ITC Cable, 20\/50 PVC Cable, 20\/50 Tray Instrument Cable, 20\/50 Tray Instrumentation Cable, 20\/50 SPOS Cable, 20\/50 Low-Voltage Tray Cable, 20\/50 Shielded Tray Cable, 20\/50 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.278 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 902 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-50PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440116547684,"sku":"NNC33618X","price":9.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_e5b76914-9932-4781-98d8-0c658d71169a.jpg?v=1762478518"},{"product_id":"18-awg-1-triad-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 1 Triad PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e18 AWG 1 Triad PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/1 Cable Tray, 18\/1 Cable Tray Types, 18\/1 Electrical Cable Tray, 18\/1 Pvc Cable Tray, 18\/1 wire cable tray, 18\/1 cable tray wire, 18\/1 PLTC Cable, 18\/1 ITC Cable, 18\/1 PVC Cable, 18\/1 Tray Instrument Cable, 18\/1 Tray Instrumentation Cable, 18\/1 STOS Cable, 18\/1 Low-Voltage Tray Cable, 18\/1 Shielded Tray Cable, 18\/1 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Triad :\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.035\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.247 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 43 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eK41803\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440146628708,"sku":"NNC33619X","price":0.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_f75355b5-f7c2-412f-960d-5d6333773232.jpg?v=1762478519"},{"product_id":"18-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e18 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/2 Cable Tray, 18\/2 Cable Tray Types, 18\/2 Electrical Cable Tray, 18\/2 Pvc Cable Tray, 18\/2 wire cable tray, 18\/2 cable tray wire, 18\/2 PLTC Cable, 18\/2 ITC Cable, 18\/2 PVC Cable, 18\/2 Tray Instrument Cable, 18\/2 Tray Instrumentation Cable, 18\/2 SPOS Cable, 18\/2 Low-Voltage Tray Cable, 18\/2 Shielded Tray Cable, 18\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.382 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 84 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440156426340,"sku":"NNC33620X","price":0.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_7d814928-152d-410f-b2f6-8a630e8ae62b.jpg?v=1762478519"},{"product_id":"18-awg-3p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 3P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e18 AWG 3P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e18\/3 Cable Tray, 18\/3 Cable Tray Types, 18\/3 Electrical Cable Tray, 18\/3 Pvc Cable Tray, 18\/3 wire cable tray, 18\/3 cable tray wire, 18\/3 PLTC Cable, 18\/3 ITC Cable, 18\/3 PVC Cable, 18\/3 Tray Instrument Cable, 18\/3 Tray Instrumentation Cable, 18\/3 SPOS Cable, 18\/3 Low-Voltage Tray Cable, 18\/3 Shielded Tray Cable, 18\/3 Power Limited Tray Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.470 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 122 lbs\u003c\/p\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31440177987684,"sku":"NNC33621X","price":0.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_028475c0-71c3-4159-abb5-d3c1265b4c6b.jpg?v=1762478521"},{"product_id":"18-4-pairs-individual-overall-shield-pltc-pvc-cable-300v","title":"18 AWG 4P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e18 AWG 4P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/4 Cable Tray, 18\/4 Cable Tray Types, 18\/4 Electrical Cable Tray, 18\/4 Pvc Cable Tray, 18\/4 wire cable tray, 18\/4 cable tray wire, 18\/4 PLTC Cable, 18\/4 ITC Cable, 18\/4 PVC Cable, 18\/4 Tray Instrument Cable, 18\/4 Tray Instrumentation Cable, 18\/4 SPOS Cable, 18\/4 Low-Voltage Tray Cable, 18\/4 Shielded Tray Cable, 18\/4 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.443 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 121 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-04PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441736073316,"sku":"NNC33622X","price":1.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_77b47fdd-1a7f-44ee-8e22-87f4aba267ab.jpg?v=1762478521"},{"product_id":"18-awg-6p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 6P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e18 AWG 6P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/6 Cable Tray, 18\/6 Cable Tray Types, 18\/6 Electrical Cable Tray, 18\/6 Pvc Cable Tray, 18\/6 wire cable tray, 18\/6 cable tray wire, 18\/6 PLTC Cable, 18\/6 ITC Cable, 18\/6 PVC Cable, 18\/6 Tray Instrument Cable, 18\/6 Tray Instrumentation Cable, 18\/6 SPOS Cable, 18\/6 Low-Voltage Tray Cable, 18\/6 Shielded Tray Cable, 18\/6 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.510 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 166 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-06PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441743315044,"sku":"NNC33623X","price":2.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_69a61cfa-8074-40e2-bedd-fc27098e8574.jpg?v=1762478522"},{"product_id":"18-awg-8p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 8P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e18 AWG 8P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/8 Cable Tray, 18\/8 Cable Tray Types, 18\/8 Electrical Cable Tray, 18\/8 Pvc Cable Tray, 18\/8 wire cable tray, 18\/8 cable tray wire, 18\/8 PLTC Cable, 18\/8 ITC Cable, 18\/8 PVC Cable, 18\/8 Tray Instrument Cable, 18\/8 Tray Instrumentation Cable, 18\/8 SPOS Cable, 18\/8 Low-Voltage Tray Cable, 18\/8 Shielded Tray Cable, 18\/8 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.577 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 211 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-08PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441748852836,"sku":"NNC33624X","price":2.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_b280c188-ee7d-4e7a-838d-d0e0e6d6d315.jpg?v=1762478522"},{"product_id":"18-awg-12p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 12P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e18 AWG 12P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/12 Cable Tray, 18\/12 Cable Tray Types, 18\/12 Electrical Cable Tray, 18\/12 Pvc Cable Tray, 18\/12 wire cable tray, 18\/12 cable tray wire, 18\/12 PLTC Cable, 18\/12 ITC Cable, 18\/12 PVC Cable, 18\/12 Tray Instrument Cable, 18\/12 Tray Instrumentation Cable, 18\/12 SPOS Cable, 18\/12 Low-Voltage Tray Cable, 18\/12 Shielded Tray Cable, 18\/12 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.060\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.743 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 327 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-12PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441758257252,"sku":"NNC33625X","price":4.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_af109021-3924-41d9-9bf8-b7a45d31b133.jpg?v=1762478524"},{"product_id":"18-awg-24p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"18 AWG 24P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e18 AWG 24P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/24 Cable Tray, 18\/24 Cable Tray Types, 18\/24 Electrical Cable Tray, 18\/24 Pvc Cable Tray, 18\/24 wire cable tray, 18\/24 cable tray wire, 18\/24 PLTC Cable, 18\/24 ITC Cable, 18\/24 PVC Cable, 18\/24 Tray Instrument Cable, 18\/24 Tray Instrumentation Cable, 18\/24 SPOS Cable, 18\/24 Low-Voltage Tray Cable, 18\/24 Shielded Tray Cable, 18\/24 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.070\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.187 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 870 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-24PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441779032164,"sku":"NNC33626X","price":6.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_65c2391c-745a-420e-b83f-24689134fe0f.jpg?v=1762478523"},{"product_id":"16-awg-1-triad-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"16 AWG 1 Triad PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e16 AWG 1 Triad PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e16\/1 Cable Tray, 16\/1 Cable Tray Types, 16\/1 Electrical Cable Tray, 16\/1 Pvc Cable Tray, 16\/1 wire cable tray, 16\/1 cable tray wire, 16\/1 PLTC Cable, 16\/1 ITC Cable, 16\/1 PVC Cable, 16\/1 Tray Instrument Cable, 16\/1 Tray Instrumentation Cable, 16\/1 STOS Cable, 16\/1 Low-Voltage Tray Cable, 16\/1 Shielded Tray Cable, 16\/1 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Number of Triad :\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.035\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.247 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 43 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eK41803\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441829101668,"sku":"NNC33627X","price":0.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_0bff2f0d-74eb-4794-8489-9b050688f0b0.jpg?v=1762478525"},{"product_id":"16-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"16 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e16 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e16\/2 Cable Tray, 16\/2 Cable Tray Types, 16\/2 Electrical Cable Tray, 16\/2 Pvc Cable Tray, 16\/2 wire cable tray, 16\/2 cable tray wire, 16\/2 PLTC Cable, 16\/2 ITC Cable, 16\/2 PVC Cable, 16\/2 Tray Instrument Cable, 16\/2 Tray Instrumentation Cable, 16\/2 SPOS Cable, 16\/2 Low-Voltage Tray Cable, 16\/2 Shielded Tray Cable, 16\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.050\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.446 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 120 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e16-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31441906892900,"sku":"NNC33628X","price":0.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_5c33280e-3647-4d2f-89d0-c301763d2d02.jpg?v=1762478525"},{"product_id":"16-awg-4p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"16 AWG 4P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e16 AWG 4P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e16\/4 Cable Tray, 16\/4 Cable Tray Types, 16\/4 Electrical Cable Tray, 16\/4 Pvc Cable Tray, 16\/4 wire cable tray, 16\/4 cable tray wire, 16\/4 PLTC Cable, 16\/4 ITC Cable, 16\/4 PVC Cable, 16\/4 Tray Instrument Cable, 16\/4 Tray Instrumentation Cable, 16\/4 SPOS Cable, 16\/4 Low-Voltage Tray Cable, 16\/4 Shielded Tray Cable, 16\/4 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.050\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.516 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 174 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e16-04PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31442055757924,"sku":"NNC33629X","price":1.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_2a513e31-2b55-4392-a2e5-f25fe21fb365.jpg?v=1762478526"},{"product_id":"16-awg-6p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"16 AWG 6P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e16 AWG 6P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e16\/6 Cable Tray, 16\/6 Cable Tray Types, 16\/6 Electrical Cable Tray, 16\/6 Pvc Cable Tray, 16\/6 wire cable tray, 16\/6 cable tray wire, 16\/6 PLTC Cable, 16\/6 ITC Cable, 16\/6 PVC Cable, 16\/6 Tray Instrument Cable, 16\/6 Tray Instrumentation Cable, 16\/6 SPOS Cable, 16\/6 Low-Voltage Tray Cable, 16\/6 Shielded Tray Cable, 16\/6 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.060\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.623 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 254 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31606\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":31442084855908,"sku":"NNC33630X","price":2.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_08b80c7b-079a-42ae-b677-78c80df81adf.jpg?v=1759810157"},{"product_id":"250-20-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/2 Cable Tray, 20\/2 Cable Tray Types, 20\/2 Electrical Cable Tray, 20\/2 Pvc Cable Tray, 20\/2 wire cable tray, 20\/2 cable tray wire, 20\/2 PLTC Cable, 20\/2 ITC Cable, 20\/2 PVC Cable, 20\/2 Tray Instrument Cable, 20\/2 Tray Instrumentation Cable, 20\/2 SPOS Cable, 20\/2 Low-Voltage Tray Cable, 20\/2 Shielded Tray Cable, 20\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.349 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 66 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402931028337,"sku":"NNC33610X250","price":162.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_300ec0d6-50f5-4ff3-868f-a07b50e8e0ac.jpg?v=1762478512"},{"product_id":"500-20-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/2 Cable Tray, 20\/2 Cable Tray Types, 20\/2 Electrical Cable Tray, 20\/2 Pvc Cable Tray, 20\/2 wire cable tray, 20\/2 cable tray wire, 20\/2 PLTC Cable, 20\/2 ITC Cable, 20\/2 PVC Cable, 20\/2 Tray Instrument Cable, 20\/2 Tray Instrumentation Cable, 20\/2 SPOS Cable, 20\/2 Low-Voltage Tray Cable, 20\/2 Shielded Tray Cable, 20\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.349 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 66 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402931487089,"sku":"NNC33610X500","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_300ec0d6-50f5-4ff3-868f-a07b50e8e0ac.jpg?v=1762478512"},{"product_id":"1000-20-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/2 Cable Tray, 20\/2 Cable Tray Types, 20\/2 Electrical Cable Tray, 20\/2 Pvc Cable Tray, 20\/2 wire cable tray, 20\/2 cable tray wire, 20\/2 PLTC Cable, 20\/2 ITC Cable, 20\/2 PVC Cable, 20\/2 Tray Instrument Cable, 20\/2 Tray Instrumentation Cable, 20\/2 SPOS Cable, 20\/2 Low-Voltage Tray Cable, 20\/2 Shielded Tray Cable, 20\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.349 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 66 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402931978609,"sku":"NNC33610X1000","price":590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_300ec0d6-50f5-4ff3-868f-a07b50e8e0ac.jpg?v=1762478512"},{"product_id":"250-20-awg-4p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 4P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 4P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/4 Cable Tray, 20\/4 Cable Tray Types, 20\/4 Electrical Cable Tray, 20\/4 Pvc Cable Tray, 20\/4 wire cable tray, 20\/4 cable tray wire, 20\/4 PLTC Cable, 20\/4 ITC Cable, 20\/4 PVC Cable, 20\/4 Tray Instrument Cable, 20\/4 Tray Instrumentation Cable, 20\/4 SPOS Cable, 20\/4 Low-Voltage Tray Cable, 20\/4 Shielded Tray Cable, 20\/4 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.423 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 101 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-04PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402935452017,"sku":"NNC33611X250","price":247.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_ac28b62a-0b67-45f1-b9e2-8c73f71ab54d.jpg?v=1762478513"},{"product_id":"500-20-awg-4p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 4P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 4P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/4 Cable Tray, 20\/4 Cable Tray Types, 20\/4 Electrical Cable Tray, 20\/4 Pvc Cable Tray, 20\/4 wire cable tray, 20\/4 cable tray wire, 20\/4 PLTC Cable, 20\/4 ITC Cable, 20\/4 PVC Cable, 20\/4 Tray Instrument Cable, 20\/4 Tray Instrumentation Cable, 20\/4 SPOS Cable, 20\/4 Low-Voltage Tray Cable, 20\/4 Shielded Tray Cable, 20\/4 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.423 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 101 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-04PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402936435057,"sku":"NNC33611X500","price":480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_ac28b62a-0b67-45f1-b9e2-8c73f71ab54d.jpg?v=1762478513"},{"product_id":"1000-20-awg-4p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 4P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 4P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/4 Cable Tray, 20\/4 Cable Tray Types, 20\/4 Electrical Cable Tray, 20\/4 Pvc Cable Tray, 20\/4 wire cable tray, 20\/4 cable tray wire, 20\/4 PLTC Cable, 20\/4 ITC Cable, 20\/4 PVC Cable, 20\/4 Tray Instrument Cable, 20\/4 Tray Instrumentation Cable, 20\/4 SPOS Cable, 20\/4 Low-Voltage Tray Cable, 20\/4 Shielded Tray Cable, 20\/4 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.423 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 101 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-04PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402939941233,"sku":"NNC33611X1000","price":920.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_ac28b62a-0b67-45f1-b9e2-8c73f71ab54d.jpg?v=1762478513"},{"product_id":"250-20-awg-8p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 8P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 8P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/8 Cable Tray, 20\/8 Cable Tray Types, 20\/8 Electrical Cable Tray, 20\/8 Pvc Cable Tray, 20\/8 wire cable tray, 20\/8 cable tray wire, 20\/8 PLTC Cable, 20\/8 ITC Cable, 20\/8 PVC Cable, 20\/8 Tray Instrument Cable, 20\/8 Tray Instrumentation Cable, 20\/8 SPOS Cable, 20\/8 Low-Voltage Tray Cable, 20\/8 Shielded Tray Cable, 20\/8 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.543 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 170 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-08PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402941514097,"sku":"NNC33612X250","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_dddd471d-2e63-4af8-938b-2999f20f81b4.jpg?v=1762478514"},{"product_id":"500-20-awg-8p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 8P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 8P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/8 Cable Tray, 20\/8 Cable Tray Types, 20\/8 Electrical Cable Tray, 20\/8 Pvc Cable Tray, 20\/8 wire cable tray, 20\/8 cable tray wire, 20\/8 PLTC Cable, 20\/8 ITC Cable, 20\/8 PVC Cable, 20\/8 Tray Instrument Cable, 20\/8 Tray Instrumentation Cable, 20\/8 SPOS Cable, 20\/8 Low-Voltage Tray Cable, 20\/8 Shielded Tray Cable, 20\/8 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.543 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 170 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-08PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402944102769,"sku":"NNC33612X500","price":995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_dddd471d-2e63-4af8-938b-2999f20f81b4.jpg?v=1762478514"},{"product_id":"1000-20-awg-8p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c-1","title":"1000' 20 AWG 8P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 8P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/8 Cable Tray, 20\/8 Cable Tray Types, 20\/8 Electrical Cable Tray, 20\/8 Pvc Cable Tray, 20\/8 wire cable tray, 20\/8 cable tray wire, 20\/8 PLTC Cable, 20\/8 ITC Cable, 20\/8 PVC Cable, 20\/8 Tray Instrument Cable, 20\/8 Tray Instrumentation Cable, 20\/8 SPOS Cable, 20\/8 Low-Voltage Tray Cable, 20\/8 Shielded Tray Cable, 20\/8 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.055\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.543 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 170 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-08PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402945872241,"sku":"NNC33612X1000","price":1940.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_dddd471d-2e63-4af8-938b-2999f20f81b4.jpg?v=1762478514"},{"product_id":"250-20-awg-12p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 12P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 12P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/12 Cable Tray, 20\/12 Cable Tray Types, 20\/12 Electrical Cable Tray, 20\/12 Pvc Cable Tray, 20\/12 wire cable tray, 20\/12 cable tray wire, 20\/12 PLTC Cable, 20\/12 ITC Cable, 20\/12 PVC Cable, 20\/12 Tray Instrument Cable, 20\/12 Tray Instrumentation Cable, 20\/12 SPOS Cable, 20\/12 Low-Voltage Tray Cable, 20\/12 Shielded Tray Cable, 20\/12 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.674 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 250 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-12PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402951180657,"sku":"NNC33613X250","price":705.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_b250ae51-e810-4c46-86b2-b581c7aaf69f.jpg?v=1762478515"},{"product_id":"500-20-awg-12p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 12P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 12P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/12 Cable Tray, 20\/12 Cable Tray Types, 20\/12 Electrical Cable Tray, 20\/12 Pvc Cable Tray, 20\/12 wire cable tray, 20\/12 cable tray wire, 20\/12 PLTC Cable, 20\/12 ITC Cable, 20\/12 PVC Cable, 20\/12 Tray Instrument Cable, 20\/12 Tray Instrumentation Cable, 20\/12 SPOS Cable, 20\/12 Low-Voltage Tray Cable, 20\/12 Shielded Tray Cable, 20\/12 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.674 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 250 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-12PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402954228081,"sku":"NNC33613X500","price":1375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_b250ae51-e810-4c46-86b2-b581c7aaf69f.jpg?v=1762478515"},{"product_id":"1000-20-awg-12p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 12P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 12P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/12 Cable Tray, 20\/12 Cable Tray Types, 20\/12 Electrical Cable Tray, 20\/12 Pvc Cable Tray, 20\/12 wire cable tray, 20\/12 cable tray wire, 20\/12 PLTC Cable, 20\/12 ITC Cable, 20\/12 PVC Cable, 20\/12 Tray Instrument Cable, 20\/12 Tray Instrumentation Cable, 20\/12 SPOS Cable, 20\/12 Low-Voltage Tray Cable, 20\/12 Shielded Tray Cable, 20\/12 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 12\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.674 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 250 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-12PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402955440497,"sku":"NNC33613X1000","price":2650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_b250ae51-e810-4c46-86b2-b581c7aaf69f.jpg?v=1762478515"},{"product_id":"250-20-awg-16p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c-copy","title":"250' 20 AWG 16P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 16P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/16 Cable Tray, 20\/16 Cable Tray Types, 20\/16 Electrical Cable Tray, 20\/16 Pvc Cable Tray, 20\/16 wire cable tray, 20\/16 cable tray wire, 20\/16 PLTC Cable, 20\/16 ITC Cable, 20\/16 PVC Cable, 20\/16 Tray Instrument Cable, 20\/16 Tray Instrumentation Cable, 20\/16 SPOS Cable, 20\/16 Low-Voltage Tray Cable, 20\/16 Shielded Tray Cable, 20\/16 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.747 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 315 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-16PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402957111665,"sku":"NNC33614X250","price":862.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_3ff493c9-2da6-45b4-98b8-b31fe3388a8c.jpg?v=1762478515"},{"product_id":"500-20-awg-16p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 16P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 16P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/16 Cable Tray, 20\/16 Cable Tray Types, 20\/16 Electrical Cable Tray, 20\/16 Pvc Cable Tray, 20\/16 wire cable tray, 20\/16 cable tray wire, 20\/16 PLTC Cable, 20\/16 ITC Cable, 20\/16 PVC Cable, 20\/16 Tray Instrument Cable, 20\/16 Tray Instrumentation Cable, 20\/16 SPOS Cable, 20\/16 Low-Voltage Tray Cable, 20\/16 Shielded Tray Cable, 20\/16 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.747 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 315 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-16PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402958881137,"sku":"NNC33614X500","price":1695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_3ff493c9-2da6-45b4-98b8-b31fe3388a8c.jpg?v=1762478515"},{"product_id":"1000-20-awg-16p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 16P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 16P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/16 Cable Tray, 20\/16 Cable Tray Types, 20\/16 Electrical Cable Tray, 20\/16 Pvc Cable Tray, 20\/16 wire cable tray, 20\/16 cable tray wire, 20\/16 PLTC Cable, 20\/16 ITC Cable, 20\/16 PVC Cable, 20\/16 Tray Instrument Cable, 20\/16 Tray Instrumentation Cable, 20\/16 SPOS Cable, 20\/16 Low-Voltage Tray Cable, 20\/16 Shielded Tray Cable, 20\/16 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.747 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 315 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-16PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402964222321,"sku":"NNC33614X1000","price":3350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_3ff493c9-2da6-45b4-98b8-b31fe3388a8c.jpg?v=1762478515"},{"product_id":"250-20-awg-20p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 20P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 20P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/20 Cable Tray, 20\/20 Cable Tray Types, 20\/20 Electrical Cable Tray, 20\/20 Pvc Cable Tray, 20\/20 wire cable tray, 20\/20 cable tray wire, 20\/20 PLTC Cable, 20\/20 ITC Cable, 20\/20 PVC Cable, 20\/20 Tray Instrument Cable, 20\/20 Tray Instrumentation Cable, 20\/20 SPOS Cable, 20\/20 Low-Voltage Tray Cable, 20\/20 Shielded Tray Cable, 20\/20 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.827 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 382 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-20PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402964681073,"sku":"NNC33615X250","price":1175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_15a237b4-8647-4de8-9260-2dc46f4183f7.jpg?v=1762478516"},{"product_id":"500-20-awg-20p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 20P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 20P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/20 Cable Tray, 20\/20 Cable Tray Types, 20\/20 Electrical Cable Tray, 20\/20 Pvc Cable Tray, 20\/20 wire cable tray, 20\/20 cable tray wire, 20\/20 PLTC Cable, 20\/20 ITC Cable, 20\/20 PVC Cable, 20\/20 Tray Instrument Cable, 20\/20 Tray Instrumentation Cable, 20\/20 SPOS Cable, 20\/20 Low-Voltage Tray Cable, 20\/20 Shielded Tray Cable, 20\/20 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.827 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 382 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-20PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402966974833,"sku":"NNC33615X500","price":2275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_15a237b4-8647-4de8-9260-2dc46f4183f7.jpg?v=1762478516"},{"product_id":"1000-20-awg-20p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 20P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 20P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/20 Cable Tray, 20\/20 Cable Tray Types, 20\/20 Electrical Cable Tray, 20\/20 Pvc Cable Tray, 20\/20 wire cable tray, 20\/20 cable tray wire, 20\/20 PLTC Cable, 20\/20 ITC Cable, 20\/20 PVC Cable, 20\/20 Tray Instrument Cable, 20\/20 Tray Instrumentation Cable, 20\/20 SPOS Cable, 20\/20 Low-Voltage Tray Cable, 20\/20 Shielded Tray Cable, 20\/20 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.066\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.827 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 382 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-20PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402969923953,"sku":"NNC33615X1000","price":4300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_15a237b4-8647-4de8-9260-2dc46f4183f7.jpg?v=1762478516"},{"product_id":"250-20-awg-24p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 24P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 24P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/24 Cable Tray, 20\/24 Cable Tray Types, 20\/24 Electrical Cable Tray, 20\/24 Pvc Cable Tray, 20\/24 wire cable tray, 20\/24 cable tray wire, 20\/24 PLTC Cable, 20\/24 ITC Cable, 20\/24 PVC Cable, 20\/24 Tray Instrument Cable, 20\/24 Tray Instrumentation Cable, 20\/24 STOS Cable, 20\/24 Low-Voltage Tray Cable, 20\/24 Shielded Tray Cable, 20\/24 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.939 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 466 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-24PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402971595121,"sku":"NNC33616X250","price":1287.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_8d28a72b-b727-4e58-83a0-fa9387c7b75e.jpg?v=1762478516"},{"product_id":"500-20-awg-24p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 24P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 24P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/24 Cable Tray, 20\/24 Cable Tray Types, 20\/24 Electrical Cable Tray, 20\/24 Pvc Cable Tray, 20\/24 wire cable tray, 20\/24 cable tray wire, 20\/24 PLTC Cable, 20\/24 ITC Cable, 20\/24 PVC Cable, 20\/24 Tray Instrument Cable, 20\/24 Tray Instrumentation Cable, 20\/24 STOS Cable, 20\/24 Low-Voltage Tray Cable, 20\/24 Shielded Tray Cable, 20\/24 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.939 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 466 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-24PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402972152177,"sku":"NNC33616X500","price":2400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_8d28a72b-b727-4e58-83a0-fa9387c7b75e.jpg?v=1762478516"},{"product_id":"1000-20-awg-24p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 24P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"[short]\n\u003ch4\u003e20 AWG 24P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/24 Cable Tray, 20\/24 Cable Tray Types, 20\/24 Electrical Cable Tray, 20\/24 Pvc Cable Tray, 20\/24 wire cable tray, 20\/24 cable tray wire, 20\/24 PLTC Cable, 20\/24 ITC Cable, 20\/24 PVC Cable, 20\/24 Tray Instrument Cable, 20\/24 Tray Instrumentation Cable, 20\/24 STOS Cable, 20\/24 Low-Voltage Tray Cable, 20\/24 Shielded Tray Cable, 20\/24 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.939 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 466 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-24PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63402972447089,"sku":"NNC33616X1000","price":4650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_8d28a72b-b727-4e58-83a0-fa9387c7b75e.jpg?v=1762478516"},{"product_id":"250-20-awg-36p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 36P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 36P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/36 Cable Tray, 20\/36 Cable Tray Types, 20\/36 Electrical Cable Tray, 20\/36 Pvc Cable Tray, 20\/36 wire cable tray, 20\/36 cable tray wire, 20\/36 PLTC Cable, 20\/36 ITC Cable, 20\/36 PVC Cable, 20\/36 Tray Instrument Cable, 20\/36 Tray Instrumentation Cable, 20\/36 SPOS Cable, 20\/36 Low-Voltage Tray Cable, 20\/36 Shielded Tray Cable, 20\/36 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 36\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.070 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 655 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-36PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403000988017,"sku":"NNC33617X250","price":1985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_68889599-f0ac-4488-aaac-9c62e10fd17b.jpg?v=1762478518"},{"product_id":"500-20-awg-36p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 36P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 36P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/36 Cable Tray, 20\/36 Cable Tray Types, 20\/36 Electrical Cable Tray, 20\/36 Pvc Cable Tray, 20\/36 wire cable tray, 20\/36 cable tray wire, 20\/36 PLTC Cable, 20\/36 ITC Cable, 20\/36 PVC Cable, 20\/36 Tray Instrument Cable, 20\/36 Tray Instrumentation Cable, 20\/36 SPOS Cable, 20\/36 Low-Voltage Tray Cable, 20\/36 Shielded Tray Cable, 20\/36 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 36\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.070 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 655 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-36PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403027988849,"sku":"NNC33617X500","price":3945.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_68889599-f0ac-4488-aaac-9c62e10fd17b.jpg?v=1762478518"},{"product_id":"1000-20-awg-36p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 36P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 36P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/36 Cable Tray, 20\/36 Cable Tray Types, 20\/36 Electrical Cable Tray, 20\/36 Pvc Cable Tray, 20\/36 wire cable tray, 20\/36 cable tray wire, 20\/36 PLTC Cable, 20\/36 ITC Cable, 20\/36 PVC Cable, 20\/36 Tray Instrument Cable, 20\/36 Tray Instrumentation Cable, 20\/36 SPOS Cable, 20\/36 Low-Voltage Tray Cable, 20\/36 Shielded Tray Cable, 20\/36 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 36\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.070 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 655 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 304px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-36PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403080679793,"sku":"NNC33617X1000","price":7850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_68889599-f0ac-4488-aaac-9c62e10fd17b.jpg?v=1762478518"},{"product_id":"250-20-awg-50p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 20 AWG 50P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 50P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/50 Cable Tray, 20\/50 Cable Tray Types, 20\/50 Electrical Cable Tray, 20\/50 Pvc Cable Tray, 20\/50 wire cable tray, 20\/50 cable tray wire, 20\/50 PLTC Cable, 20\/50 ITC Cable, 20\/50 PVC Cable, 20\/50 Tray Instrument Cable, 20\/50 Tray Instrumentation Cable, 20\/50 SPOS Cable, 20\/50 Low-Voltage Tray Cable, 20\/50 Shielded Tray Cable, 20\/50 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.278 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 902 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-50PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403092672881,"sku":"NNC33618X250","price":2280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_e5b76914-9932-4781-98d8-0c658d71169a.jpg?v=1762478518"},{"product_id":"500-20-awg-50p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 20 AWG 50P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 50P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/50 Cable Tray, 20\/50 Cable Tray Types, 20\/50 Electrical Cable Tray, 20\/50 Pvc Cable Tray, 20\/50 wire cable tray, 20\/50 cable tray wire, 20\/50 PLTC Cable, 20\/50 ITC Cable, 20\/50 PVC Cable, 20\/50 Tray Instrument Cable, 20\/50 Tray Instrumentation Cable, 20\/50 SPOS Cable, 20\/50 Low-Voltage Tray Cable, 20\/50 Shielded Tray Cable, 20\/50 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.278 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 902 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-50PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403103060337,"sku":"NNC33618X500","price":4495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_e5b76914-9932-4781-98d8-0c658d71169a.jpg?v=1762478518"},{"product_id":"1000-20-awg-50p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"1000' 20 AWG 50P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e20 AWG 50P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e20\/50 Cable Tray, 20\/50 Cable Tray Types, 20\/50 Electrical Cable Tray, 20\/50 Pvc Cable Tray, 20\/50 wire cable tray, 20\/50 cable tray wire, 20\/50 PLTC Cable, 20\/50 ITC Cable, 20\/50 PVC Cable, 20\/50 Tray Instrument Cable, 20\/50 Tray Instrumentation Cable, 20\/50 SPOS Cable, 20\/50 Low-Voltage Tray Cable, 20\/50 Shielded Tray Cable, 20\/50 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.018 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.078\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 1.278 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 902 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eL32050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003e20-50PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\"\u003eHW10302050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403114332529,"sku":"NNC33618X1000","price":8780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_e5b76914-9932-4781-98d8-0c658d71169a.jpg?v=1762478518"},{"product_id":"250-18-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"250' 18 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e18 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/2 Cable Tray, 18\/2 Cable Tray Types, 18\/2 Electrical Cable Tray, 18\/2 Pvc Cable Tray, 18\/2 wire cable tray, 18\/2 cable tray wire, 18\/2 PLTC Cable, 18\/2 ITC Cable, 18\/2 PVC Cable, 18\/2 Tray Instrument Cable, 18\/2 Tray Instrumentation Cable, 18\/2 SPOS Cable, 18\/2 Low-Voltage Tray Cable, 18\/2 Shielded Tray Cable, 18\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.382 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 84 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403123376497,"sku":"NNC33620X250","price":202.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_7d814928-152d-410f-b2f6-8a630e8ae62b.jpg?v=1762478519"},{"product_id":"500-18-awg-2p-pltc-itc-individual-overall-shield-instrumentation-tray-cable-pvc-jacket-300v-105-c","title":"500' 18 AWG 2P PLTC\/ITC Individual \u0026 Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch4\u003e18 AWG 2P PLTC\/ITC Individual \u0026amp; Overall Shield Instrumentation Tray Cable PVC Jacket 300V 105°C\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePower Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. PLTC SPOS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable trays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e18\/2 Cable Tray, 18\/2 Cable Tray Types, 18\/2 Electrical Cable Tray, 18\/2 Pvc Cable Tray, 18\/2 wire cable tray, 18\/2 cable tray wire, 18\/2 PLTC Cable, 18\/2 ITC Cable, 18\/2 PVC Cable, 18\/2 Tray Instrument Cable, 18\/2 Tray Instrumentation Cable, 18\/2 SPOS Cable, 18\/2 Low-Voltage Tray Cable, 18\/2 Shielded Tray Cable, 18\/2 Power Limited Tray Cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eStandards:\u003cbr\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL listed as type PLTC \u0026amp; CL3 per UL standard 13 and as type ITC per UL standard 2250\u003cbr\u003e• Suitable for installations under NEC (NFPA 70) article 725 and article 727 guidelines\u003cbr\u003e• Suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• EPA 40 CFR, part 261\u003cbr\u003e• Cold bend rating of -40°C\u003cbr\u003e• UL approved for Sunlight Resistant Applications meets IEEE 1202 flame test\u003cbr\u003e• (UL) ITC Sunlight Resistant or PLTC or CL3 FT4\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eConductor: \u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• 7 Strand class B annealed bare copper conductor, per ASTM B3 \u0026amp; B8\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eInsulation:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) insulation\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eShield:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Aluminum polyester foil with 100% coverage on each pair, with an overall aluminum polyester foil with 100% coverage with a tinned copper drain wire in contact with all shields\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e• Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size AWG :\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• Number of Pairs :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Insulation Thickness : \u003c\/strong\u003e0.016 \u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Jacket Thickness : \u003c\/strong\u003e0.045\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eI\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enches\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outside Diameter :\u003c\/strong\u003e 0.382 Inches\u003cbr\u003e\u003cstrong\u003e• Temperature Rating :\u003c\/strong\u003e 105°C\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 300V\u003cbr\u003e\u003cstrong\u003e• Weight 1000ft :\u003c\/strong\u003e 84 lbs\u003c\/p\u003e\n\u003ctable style=\"width: 322px;\" data-mce-style=\"width: 322px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\" data-mce-style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 304px; height: 21px;\" data-mce-style=\"width: 304px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eL31802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003ePriority Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003e18-02PRPLTC-SPOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\" data-mce-style=\"width: 151px;\"\u003e\u003cstrong\u003eHouston Wire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153px;\" data-mce-style=\"width: 153px;\"\u003eHW10301802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63403129405809,"sku":"NNC33620X500","price":390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/OSPLTC3_7d814928-152d-410f-b2f6-8a630e8ae62b.jpg?v=1762478519"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/instrumentation-tray-cable-pltc-itc-individual-overall-shield-pvc-jacket-300v-105-c.oembed?page=4","provider":"NassauNationalCable","version":"1.0","type":"link"}