{"title":"IEEE 1580 Type TP(OS)LSEL Signal Cable Aluminum \/ Bronze Armored 300V","description":"","products":[{"product_id":"tp18islsela-1-18-awg-1-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-1 18 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-1 18 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.305 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.368 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 63 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 76 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-1\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37495066525850,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_356a10ed-3bc3-40a6-87b1-c2cff781f41d.jpg?v=1762480680"},{"product_id":"tp18islsela-2-18-awg-2-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-2 18 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-2 18 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 2\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.459 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.522 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 108.15 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 128 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-2\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37495367106714,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_4812cc3b-fc3b-4e90-8684-46af59faadf4.jpg?v=1762480681"},{"product_id":"tp18islsela-3-18-awg-3-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-3 18 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-3 18 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 3\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.488 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.551 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 134.4 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 153 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-3\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37495411114138,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_f86c744b-2dad-42b9-9197-d9d377db465e.jpg?v=1762480681"},{"product_id":"tp18islsela-4-18-awg-4-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-4 18 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-4 18 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 4\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.06 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.567 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.63 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 184.8 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 205 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-4\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37495484022938,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_1d8f3d1d-d880-44a5-997b-200bf14ae112.jpg?v=1762480682"},{"product_id":"tp18islsela-5-18-awg-5-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-5 18 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-5 18 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 5\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.619 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.682 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 238.35 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 257 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-5\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37495507124378,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_442b9fd5-81ad-462f-b679-d7a25fb957cb.jpg?v=1762480682"},{"product_id":"tp18islsela-7-18-awg-7-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-7 18 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-7 18 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 7\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.672 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.735 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 283.5 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 304 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-7\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37495571415194,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_92da0391-4aab-4f84-b486-0517b6d10e8a.jpg?v=1762480684"},{"product_id":"tp18islsela-10-18-awg-10-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-10 18 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e18(IS)LSELA-10 18 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 10\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.882 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.945 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 452.55 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 476 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-10\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500073410714,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_5d1f065f-a201-48dc-a3f3-58fd59ab4600.jpg?v=1762480692"},{"product_id":"tp18islsela-15-18-awg-15-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 15\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.998 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.061 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 573.3 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 595 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-15\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500238004378,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_1a2baa05-17c2-4c2e-aba8-729d2bcf01c7.jpg?v=1762480695"},{"product_id":"tp18islsela-20-18-awg-20-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(IS)LSELA-20 18 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELA-20 18 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.112 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.175 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 754.95 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 775 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELA-20\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500269330586,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_0290dfde-a44a-4b2d-9c34-925232e4256f.jpg?v=1762480697"},{"product_id":"tp16islsela-1-16-awg-1-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-1 16 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-1 16 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.324 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.387 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 74.55 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 88 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-1\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500365045914,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_b018b9ec-aa1c-4950-ac1a-71cedd825c7f.jpg?v=1762480700"},{"product_id":"tp16islsela-2-16-awg-2-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-2 16 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eTP16(IS)LSELA-2 16 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor TP16(IS)LSELA-2 16 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003cstrong\u003e 100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor use as Signal Cables aboard ship and off-shore oil rigs. The cables are constructed in accordance with the IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eMarine Tech Cable, LSE Signal Cable, TP16(IS)LSELA-2 Signal Cable, Aluminum Armored Cable, Signal Cable, Halogen Free Cable, 300V Signal Cable\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCONDUCTOR\u003c\/strong\u003e Soft annealed bare copper per ASTM B 3 and B 8, Class C stranding. Sizes as shown in the attached tables. (tinned copper conductors and Class B stranding available on request)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eINSULATION\u003c\/strong\u003e (Type LSE) Thermosetting, Cross-linked, Low Smoke, Halogen Free, Ethylene Propylene Rubber meeting the IEEE Std 1580-2001 requirements for Type LSE insulation. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eTWISTED PAIR COMPONENT\u003c\/strong\u003e (triads available on request) Two conductors twisted together to form a pair. One conductor insulated white with one black. Color code using printed number on each pair.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCOMPONENT SHIELD\u003c\/strong\u003e (optional) Shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with individually shielded components are identified with an “IS” designation.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eASSEMBLY\u003c\/strong\u003e Components cabled together with non-hygroscopic fillers as necessary.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eBINDER \u003c\/strong\u003eCabled assembly helically wrapped with polyester binder tape.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eOVERALL SHIELD\u003c\/strong\u003e (optional) Cable shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with an Overall Cable Shield are identified with an “OS” designation.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eJACKET\u003c\/strong\u003e (Type TPO) Flame Retardant, Low Smoke, Halogen Free, Thermoplastic Polyolefin meeting the IEEE Std 1580-2001 requirements for Type TPO jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e          OR\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eJACKET\u003c\/strong\u003e (Type L) Flame Retardant, Low Smoke, Halogen Free, Thermosetting, Cross-linked Polyolefin meeting the IEEE Std 1580-2001 requirements for Type L jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eARMOR\u003c\/strong\u003e (Optional) Aluminum or Bronze Armor Braid available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eRATINGS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Passes 70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/li\u003e\n\u003cli\u003e• Temperature Rated at 90°C\u003c\/li\u003e\n\u003cli\u003e• Meets all requirements of IEEE Std 1580-2001 for Signal Cable Types LSETPO and LSEL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAPPROVALS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• UL (Underwriters Laboratories) classified Marine Shipboard Cable in Accordance with International Standard IEEE Std 1580-2001.\u003c\/li\u003e\n\u003cli\u003e• UL File E319439\u003c\/li\u003e\n\u003cli\u003e• ABS Type Approval Certificate No.10-HS592905-PDA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eAWG:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNumber of Pairs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 0.025 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.045 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Diameter (nominal):\u003c\/strong\u003e 0.492 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eArmored Cable Diameter (nom):\u003c\/strong\u003e 0.555 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight (approx.):\u003c\/strong\u003e 128.1 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eAluminum Arm. Cable Weight:\u003c\/strong\u003e 149 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Type:\u003c\/strong\u003e TP16(IS)LSELA-2\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500389949594,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_78feab1f-4495-4d5e-8c19-8eed82926794.jpg?v=1762480700"},{"product_id":"tp16islsela-3-16-awg-3-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-3 16 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-3 16 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 3\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.06 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.554 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.617 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 180.6 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 200 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-3\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500404007066,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_f48fd7e0-7cde-4d3a-bbf5-1e80f9b5bf22.jpg?v=1762480701"},{"product_id":"tp16islsela-4-16-awg-4-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-4 16 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-4 16 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 4\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.06 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.606 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.669 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 224.7 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 244 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-4\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37500410888346,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_65bce454-5383-448a-a20a-9b07c86b3310.jpg?v=1762480701"},{"product_id":"tp16islsela-5-16-awg-5-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-5 16 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-5 16 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELA-5 16 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 5\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.664 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.727 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 269.85 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 291 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-5\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502674272410,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_d2e12ba9-10de-40cf-8c52-e71cad80763d.jpg?v=1762480719"},{"product_id":"tp16islsela-7-16-awg-7-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-7 16 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-7 16 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELA-7 16 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 7\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.721 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.784 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 353.85 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 374 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-7\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502816813210,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_0ab50e80-0766-40f1-877c-4c227ce22579.jpg?v=1762480720"},{"product_id":"tp16islsela-10-16-awg-10-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-10 16 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-10 16 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELA-10 16 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 10\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.948 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.011 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 549.15 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 571 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-10\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502827626650,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_5e1cd060-e2ef-4f15-bd8e-82eae6e5c9bd.jpg?v=1762480722"},{"product_id":"tp16islsela-15-16-awg-15-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-15 16 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-15 16 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELA-15 16 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 15\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.07 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.133 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 727.65 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 748 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-15\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502832115866,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_d3a586d9-39c9-4552-91a7-1d7c63802b1d.jpg?v=1762480721"},{"product_id":"tp16islsela-20-16-awg-20-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP16(IS)LSELA-20 16 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELA-20 16 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELA-20 16 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.194 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.257 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 928.2 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Aluminum Arm. Cable Weight: 945 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELA-20\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502845059226,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_331fcf70-343a-47fb-b175-971fc6dc04ee.jpg?v=1762480723"},{"product_id":"tp20islselb-1-20-awg-1-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-1 20 AWG 1 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-1 20 AWG 1 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-1 20 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.281 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.344 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 47.25 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 95 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-1\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502857019546,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_0a86da79-7b3c-45be-88b9-1a0c792148e1.jpg?v=1762480724"},{"product_id":"tp20islselb-2-20-awg-2-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-2 20 AWG 2 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-2 20 AWG 2 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-2 20 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 2\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.418 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.481 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 85.05 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 155 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-2\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502866194586,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_8dd1ed17-08d5-481a-9be8-2012fe5fe499.jpg?v=1762480724"},{"product_id":"tp20islselb-3-20-awg-3-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-3 20 AWG 3 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-3 20 AWG 3 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-3 20 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 3\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.444 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.507 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 103.95 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 175 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-3\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502878122138,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_5143a0ec-183a-4988-bd4a-cc465d123c19.jpg?v=1762480726"},{"product_id":"tp20islselb-4-20-awg-4-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-4 20 AWG 4 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-4 20 AWG 4 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-4 20 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 4\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.485 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.548 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 129.15 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 207 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-4\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502888411290,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_e06f597f-7c86-42b4-a75c-47ab1d30705b.jpg?v=1762480727"},{"product_id":"tp20islselb-5-20-awg-5-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-5 20 AWG 5 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-5 20 AWG 5 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-5 20 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 5\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.563 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.626 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 182.7 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 269 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-5\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502898405530,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_10a8a77d-b917-463e-9b32-a7e66e205066.jpg?v=1762480728"},{"product_id":"tp20islselb-7-20-awg-7-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-7 20 AWG 7 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-7 20 AWG 7 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-7 20 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 7\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.609 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.672 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 222.6 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 312 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-7\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502908858522,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_4c651e2f-78ef-4d98-9c25-e12455f5f735.jpg?v=1762480728"},{"product_id":"tp20islselb-10-20-awg-10-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-10 20 AWG 10 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-10 20 AWG 10 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-10 20 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 10\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.759 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.822 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 316.05 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 429 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-10\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502916231322,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_536539e1-0306-4889-a889-24a62d4564b7.jpg?v=1762480729"},{"product_id":"tp20islselb-15-20-awg-15-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-15 20 AWG 15 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-15 20 AWG 15 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-15 20 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 15\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.9 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.963 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 453.6 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 582 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-15\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502922424474,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_07257174-96b9-43d2-85b9-104da255e973.jpg?v=1762480730"},{"product_id":"tp20islselb-20-20-awg-20-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP20(IS)LSELB-20 20 AWG 20 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP20(IS)LSELB-20 20 AWG 20 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP20(IS)LSELB-20 20 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.003 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.066 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 573.3 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 709 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP20(IS)LSELB-20\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502927044762,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_4ad96ce0-ece7-47ae-8527-1c344c20253a.jpg?v=1762480731"},{"product_id":"tp18islselb-1-18-awg-1-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-1 18 AWG 1 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-1 18 AWG 1 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-1 18 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.305 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.368 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 63 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 114 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-1\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502935203994,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_1f5f6ae3-0664-4993-96ec-a5c2866c7124.jpg?v=1762480731"},{"product_id":"tp18islselb-2-18-awg-2-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-2 18 AWG 2 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-2 18 AWG 2 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-2 18 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 2\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.459 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.522 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 108.15 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 185 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-2\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502939463834,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_e84b21d7-72fc-4b4f-bd14-5bff598481cb.jpg?v=1762480732"},{"product_id":"tp18islselb-3-18-awg-3-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-3 18 AWG 3 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-3 18 AWG 3 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-3 18 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 3\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.488 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.551 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 134.4 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 213 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-3\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502970396826,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_0e4651b9-8238-4df7-8419-34129bf6afee.jpg?v=1762480732"},{"product_id":"tp18islselb-4-18-awg-4-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-4 18 AWG 4 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-4 18 AWG 4 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-4 18 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 4\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.06 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.567 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.63 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 184.8 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 271 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-4\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37502984159386,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_ab315a0d-2c17-4e5c-95d1-8df5d950bd21.jpg?v=1762480734"},{"product_id":"tp18islselb-5-18-awg-5-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-5 18 AWG 5 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-5 18 AWG 5 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-5 18 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 5\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.619 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.682 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 238.35 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 328 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-5\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503007850650,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_942760de-0829-48f5-98af-cfdc65cec7d6.jpg?v=1762480734"},{"product_id":"tp18islselb-7-18-awg-7-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-7 18 AWG 7 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-7 18 AWG 7 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-7 18 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 7\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.672 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.735 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 283.5 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 384 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-7\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503017812122,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_c4cb5006-c187-4411-b0bf-d63b4f678527.jpg?v=1762480735"},{"product_id":"tp18islselb-10-18-awg-10-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-10 18 AWG 10 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-10 18 AWG 10 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-10 18 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 10\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.882 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.945 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 452.55 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 579 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-10\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503021088922,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_108ead1d-53ec-4305-bd44-c9e9e9971a4a.jpg?v=1762480735"},{"product_id":"tp18islselb-15-18-awg-15-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 15\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.998 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.061 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 573.3 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 708 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-15\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503028428954,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_932e6761-2e93-4871-a62c-0c1861d3f4aa.jpg?v=1762480736"},{"product_id":"tp18islselb-20-18-awg-20-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP18(IS)LSELB-20 18 AWG 20 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP18(IS)LSELB-20 18 AWG 20 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP18(IS)LSELB-20 18 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.112 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.175 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 754.95 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 905 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP18(IS)LSELB-20\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503040323738,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_689b4224-78d6-4162-a375-5b31fb743875.jpg?v=1762480737"},{"product_id":"tp16islselb-1-16-awg-1-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-1 16 AWG 1 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-1 16 AWG 1 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-1 16 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.324 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.387 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 74.55 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 127 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-1\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503051202714,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_66dd4f3f-7ecd-41b6-8017-cd12dcb8d4f8.jpg?v=1762480738"},{"product_id":"tp16islselb-2-16-awg-2-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-2 16 AWG 2 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-2 16 AWG 2 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-2 16 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 2\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.045 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.492 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.555 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 128.1 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 208 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-2\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503079481498,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_d5218754-4b26-4b85-8061-ffc8a6adcc2a.jpg?v=1762480738"},{"product_id":"tp16islselb-3-16-awg-3-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-3 16 AWG 3 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-3 16 AWG 3 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-3 16 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 3\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.06 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.554 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.617 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 180.6 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 266 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-3\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503147442330,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_2f61ffc7-e579-4ee2-afb6-bfd5ef02aea7.jpg?v=1762480741"},{"product_id":"tp16islselb-4-16-awg-4-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-4 16 AWG 4 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-4 16 AWG 4 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-4 16 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 4\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.06 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.606 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.669 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 224.7 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 313 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-4\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503178113178,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_cc7e38ab-c78f-4a38-bc4a-ca3f7ca3cf59.jpg?v=1762480742"},{"product_id":"tp16islselb-5-16-awg-5-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-5 16 AWG 5 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-5 16 AWG 5 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-5 16 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 5\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.664 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.727 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 269.85 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 371 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-5\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503209111706,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_1de2c883-b99f-47b2-9dbc-f35fe13f0417.jpg?v=1762480743"},{"product_id":"tp16islselb-7-16-awg-7-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-7 16 AWG 7 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-7 16 AWG 7 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-7 16 AWG 7 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 7\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.060 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.721 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 0.784 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 353.85 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 456 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-7\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503224676506,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_e0ce2e44-e86c-4a6c-b300-eae2fb019420.jpg?v=1762480743"},{"product_id":"tp16islselb-10-16-awg-10-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-10 16 AWG 10 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-10 16 AWG 10 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-10 16 AWG 10 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 10\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 0.948 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.011 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 549.15 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 680 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-10\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503237685402,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_103a913e-1ded-421d-be65-0b3801fb0047.jpg?v=1762480744"},{"product_id":"tp16islselb-15-16-awg-15-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-15 16 AWG 15 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-15 16 AWG 15 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-15 16 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 15\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.07 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.133 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 727.65 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 875 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-15\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503255838874,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_f035648c-aefe-4cb2-9bbd-3ec53ec42f5e.jpg?v=1762480744"},{"product_id":"tp16islselb-20-16-awg-20-pair-ieee-1580-type-signal-cable-bronze-armored-300v","title":"TP16(IS)LSELB-20 16 AWG 20 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTP16(IS)LSELB-20 16 AWG 20 Pair IEEE 1580 Type Signal Cable Bronze Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003efor TP16(IS)LSELB-20 16 AWG 20 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003c\/span\u003e\u003cb data-mce-fragment=\"1\"\u003e 100 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSEL signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe insulation of the cable is cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThere are two jacket options one is offered to choose from: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003ci data-mce-fragment=\"1\"\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e AWG: 16\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Number of Pairs: 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Insulation Thickness: 0.025 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Jacket Thickness: 0.080 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Diameter (nominal): 1.194 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Armored Cable Diameter (nom): 1.257 Inches\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Weight (approx.): 928.2 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Bronze Arm. Cable Weight: 1083 Lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e Cable Type: TP16(IS)LSELB-20\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37503274025114,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/IEEE1580_afadb3d4-accc-43b4-a19c-b2a63a9d6c76.jpg?v=1762480746"},{"product_id":"tp20oslsela-1-20-awg-1-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP20(OS)LSELA-1 20 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eTP20(OS)LSELA-1 20 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor TP20(OS)LSELA-1 20 AWG 1 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003cstrong\u003e 100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor use as Signal Cables aboard ship and off-shore oil rigs. The cables are constructed in accordance with the IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eMarine Tech Cable, LSE Signal Cable, TP20(OS)LSELA-1 Signal Cable, Aluminum Armored Cable, Bronze Armored Cable, Signal Cable, Halogen Free Cable, 300V Signal Cable\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCONDUCTOR\u003c\/strong\u003e Soft annealed bare copper per ASTM B 3 and B 8, Class C stranding. Sizes as shown in the attached tables. (tinned copper conductors and Class B stranding available on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINSULATION\u003c\/strong\u003e (Type LSE) Thermosetting, Cross-linked, Low Smoke, Halogen Free, Ethylene Propylene Rubber meeting the IEEE Std 1580-2001 requirements for Type LSE insulation. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTWISTED PAIR COMPONENT\u003c\/strong\u003e (triads available on request) Two conductors twisted together to form a pair. One conductor insulated white with one black. Color code using printed number on each pair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOMPONENT SHIELD\u003c\/strong\u003e (optional) Shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with individually shielded components are identified with an “IS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSEMBLY\u003c\/strong\u003e Components cabled together with non-hygroscopic fillers as necessary.\u003c\/li\u003e\n\u003cli\u003eBINDER Cabled assembly helically wrapped with polyester binder tape.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERALL SHIELD\u003c\/strong\u003e (optional) Cable shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with an Overall Cable Shield are identified with an “OS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type TPO) Flame Retardant, Low Smoke, Halogen Free, Thermoplastic Polyolefin meeting the IEEE Std 1580-2001 requirements for Type TPO jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e       OR\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type L) Flame Retardant, Low Smoke, Halogen Free, Thermosetting, Cross-linked Polyolefin meeting the IEEE Std 1580-2001 requirements for Type L jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARMOR\u003c\/strong\u003e (Optional) Aluminum or Bronze Armor Braid available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eRATINGS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Passes 70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/li\u003e\n\u003cli\u003e• Temperature Rated at 90°C\u003c\/li\u003e\n\u003cli\u003e• Meets all requirements of IEEE Std 1580-2001 for Signal Cable Types LSETPO and LSEL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAPPROVALS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• UL (Underwriters Laboratories) classified Marine Shipboard Cable in Accordance with International Standard IEEE Std 1580-2001.\u003c\/li\u003e\n\u003cli\u003e• UL File E319439\u003c\/li\u003e\n\u003cli\u003e• ABS Type Approval Certificate No.10-HS592905-PDA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eAWG:\u003c\/strong\u003e 20\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNumber of Pairs:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 0.025 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.045 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Diameter (nominal):\u003c\/strong\u003e 0.281 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eArmored Cable Diameter (nom):\u003c\/strong\u003e 0.344 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight (approx.):\u003c\/strong\u003e 47.25 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eAluminum Arm. Cable Weight:\u003c\/strong\u003e 95 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Type:\u003c\/strong\u003e TP20(OS)LSELA-1\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37651774472346,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/marine_70a683db-9790-45d7-ba85-bfa6d8a35a5f.png?v=1762481011"},{"product_id":"tp20oslsela-2-20-awg-2-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP20(OS)LSELA-2 20 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eTP20(OS)LSELA-2 20 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor TP20(OS)LSELA-2 20 AWG 2 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003cstrong\u003e 100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor use as Signal Cables aboard ship and off-shore oil rigs. The cables are constructed in accordance with the IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eMarine Tech Cable, LSE Signal Cable, TP20(OS)LSELA-2 Signal Cable, Aluminum Armored Cable, Bronze Armored Cable, Signal Cable, Halogen Free Cable, 300V Signal Cable\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCONDUCTOR\u003c\/strong\u003e Soft annealed bare copper per ASTM B 3 and B 8, Class C stranding. Sizes as shown in the attached tables. (tinned copper conductors and Class B stranding available on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINSULATION\u003c\/strong\u003e (Type LSE) Thermosetting, Cross-linked, Low Smoke, Halogen Free, Ethylene Propylene Rubber meeting the IEEE Std 1580-2001 requirements for Type LSE insulation. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTWISTED PAIR COMPONENT\u003c\/strong\u003e (triads available on request) Two conductors twisted together to form a pair. One conductor insulated white with one black. Color code using printed number on each pair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOMPONENT SHIELD\u003c\/strong\u003e (optional) Shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with individually shielded components are identified with an “IS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSEMBLY\u003c\/strong\u003e Components cabled together with non-hygroscopic fillers as necessary.\u003c\/li\u003e\n\u003cli\u003eBINDER Cabled assembly helically wrapped with polyester binder tape.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERALL SHIELD\u003c\/strong\u003e (optional) Cable shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with an Overall Cable Shield are identified with an “OS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type TPO) Flame Retardant, Low Smoke, Halogen Free, Thermoplastic Polyolefin meeting the IEEE Std 1580-2001 requirements for Type TPO jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e       OR\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type L) Flame Retardant, Low Smoke, Halogen Free, Thermosetting, Cross-linked Polyolefin meeting the IEEE Std 1580-2001 requirements for Type L jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARMOR\u003c\/strong\u003e (Optional) Aluminum or Bronze Armor Braid available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eRATINGS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Passes 70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/li\u003e\n\u003cli\u003e• Temperature Rated at 90°C\u003c\/li\u003e\n\u003cli\u003e• Meets all requirements of IEEE Std 1580-2001 for Signal Cable Types LSETPO and LSEL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAPPROVALS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• UL (Underwriters Laboratories) classified Marine Shipboard Cable in Accordance with International Standard IEEE Std 1580-2001.\u003c\/li\u003e\n\u003cli\u003e• UL File E319439\u003c\/li\u003e\n\u003cli\u003e• ABS Type Approval Certificate No.10-HS592905-PDA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eAWG:\u003c\/strong\u003e 20\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNumber of Pairs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 0.025 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.045 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Diameter (nominal):\u003c\/strong\u003e 0.435 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eArmored Cable Diameter (nom):\u003c\/strong\u003e 0.498 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight (approx.):\u003c\/strong\u003e 102.9 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eAluminum Arm.Cable Weight:\u003c\/strong\u003e 120 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Type:\u003c\/strong\u003e TP20(OS)LSELA-2\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37651803865242,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/marine_24a55d5d-07c3-4378-ac03-346ea35c73df.png?v=1762481012"},{"product_id":"tp20oslsela-3-20-awg-3-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP20(OS)LSELA-3 20 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eTP20(OS)LSELA-3 20 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor TP20(OS)LSELA-3 20 AWG 3 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003cstrong\u003e 100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor use as Signal Cables aboard ship and off-shore oil rigs. The cables are constructed in accordance with the IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eMarine Tech Cable, LSE Signal Cable, TP20(OS)LSELA-3 Signal Cable, Aluminum Armored Cable, Bronze Armored Cable, Signal Cable, Halogen Free Cable, 300V Signal Cable\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCONDUCTOR\u003c\/strong\u003e Soft annealed bare copper per ASTM B 3 and B 8, Class C stranding. Sizes as shown in the attached tables. (tinned copper conductors and Class B stranding available on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINSULATION\u003c\/strong\u003e (Type LSE) Thermosetting, Cross-linked, Low Smoke, Halogen Free, Ethylene Propylene Rubber meeting the IEEE Std 1580-2001 requirements for Type LSE insulation. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTWISTED PAIR COMPONENT\u003c\/strong\u003e (triads available on request) Two conductors twisted together to form a pair. One conductor insulated white with one black. Color code using printed number on each pair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOMPONENT SHIELD\u003c\/strong\u003e (optional) Shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with individually shielded components are identified with an “IS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSEMBLY\u003c\/strong\u003e Components cabled together with non-hygroscopic fillers as necessary.\u003c\/li\u003e\n\u003cli\u003eBINDER Cabled assembly helically wrapped with polyester binder tape.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERALL SHIELD\u003c\/strong\u003e (optional) Cable shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with an Overall Cable Shield are identified with an “OS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type TPO) Flame Retardant, Low Smoke, Halogen Free, Thermoplastic Polyolefin meeting the IEEE Std 1580-2001 requirements for Type TPO jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e       OR\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type L) Flame Retardant, Low Smoke, Halogen Free, Thermosetting, Cross-linked Polyolefin meeting the IEEE Std 1580-2001 requirements for Type L jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARMOR\u003c\/strong\u003e (Optional) Aluminum or Bronze Armor Braid available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eRATINGS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Passes 70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/li\u003e\n\u003cli\u003e• Temperature Rated at 90°C\u003c\/li\u003e\n\u003cli\u003e• Meets all requirements of IEEE Std 1580-2001 for Signal Cable Types LSETPO and LSEL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAPPROVALS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• UL (Underwriters Laboratories) classified Marine Shipboard Cable in Accordance with International Standard IEEE Std 1580-2001.\u003c\/li\u003e\n\u003cli\u003e• UL File E319439\u003c\/li\u003e\n\u003cli\u003e• ABS Type Approval Certificate No.10-HS592905-PDA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eAWG:\u003c\/strong\u003e 20\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNumber of Pairs:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 0.025 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.045 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Diameter (nominal):\u003c\/strong\u003e 0.441 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eArmored Cable Diameter (nom):\u003c\/strong\u003e 0.504 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight (approx.):\u003c\/strong\u003e 109.2 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eAluminum Arm.Cable Weight:\u003c\/strong\u003e 126 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Type:\u003c\/strong\u003e TP20(OS)LSELA-3\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37651822575770,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/marine_fe1de3ec-4b08-443a-9b32-96bb673fab36.png?v=1762481013"},{"product_id":"tp20oslsela-4-20-awg-4-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP20(OS)LSELA-4 20 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eTP20(OS)LSELA-4 20 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor TP20(OS)LSELA-4 20 AWG 4 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003cstrong\u003e 100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor use as Signal Cables aboard ship and off-shore oil rigs. The cables are constructed in accordance with the IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eMarine Tech Cable, LSE Signal Cable, TP20(OS)LSELA-4 Signal Cable, Aluminum Armored Cable, Bronze Armored Cable, Signal Cable, Halogen Free Cable, 300V Signal Cable\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCONDUCTOR\u003c\/strong\u003e Soft annealed bare copper per ASTM B 3 and B 8, Class C stranding. Sizes as shown in the attached tables. (tinned copper conductors and Class B stranding available on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINSULATION\u003c\/strong\u003e (Type LSE) Thermosetting, Cross-linked, Low Smoke, Halogen Free, Ethylene Propylene Rubber meeting the IEEE Std 1580-2001 requirements for Type LSE insulation. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTWISTED PAIR COMPONENT\u003c\/strong\u003e (triads available on request) Two conductors twisted together to form a pair. One conductor insulated white with one black. Color code using printed number on each pair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOMPONENT SHIELD\u003c\/strong\u003e (optional) Shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with individually shielded components are identified with an “IS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSEMBLY\u003c\/strong\u003e Components cabled together with non-hygroscopic fillers as necessary.\u003c\/li\u003e\n\u003cli\u003eBINDER Cabled assembly helically wrapped with polyester binder tape.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERALL SHIELD\u003c\/strong\u003e (optional) Cable shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with an Overall Cable Shield are identified with an “OS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type TPO) Flame Retardant, Low Smoke, Halogen Free, Thermoplastic Polyolefin meeting the IEEE Std 1580-2001 requirements for Type TPO jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e       OR\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type L) Flame Retardant, Low Smoke, Halogen Free, Thermosetting, Cross-linked Polyolefin meeting the IEEE Std 1580-2001 requirements for Type L jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARMOR\u003c\/strong\u003e (Optional) Aluminum or Bronze Armor Braid available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eRATINGS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Passes 70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/li\u003e\n\u003cli\u003e• Temperature Rated at 90°C\u003c\/li\u003e\n\u003cli\u003e• Meets all requirements of IEEE Std 1580-2001 for Signal Cable Types LSETPO and LSEL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAPPROVALS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• UL (Underwriters Laboratories) classified Marine Shipboard Cable in Accordance with International Standard IEEE Std 1580-2001.\u003c\/li\u003e\n\u003cli\u003e• UL File E319439\u003c\/li\u003e\n\u003cli\u003e• ABS Type Approval Certificate No.10-HS592905-PDA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eAWG:\u003c\/strong\u003e 20\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNumber of Pairs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 0.025 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.045 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Diameter (nominal):\u003c\/strong\u003e 0.480 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eArmored Cable Diameter (nom):\u003c\/strong\u003e 0.543 Inches\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight (approx.):\u003c\/strong\u003e 126 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eAluminum Arm.Cable Weight:\u003c\/strong\u003e 144 Lbs\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Type:\u003c\/strong\u003e TP20(OS)LSELA-4\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37651839451290,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/marine_4d0e7066-f0ac-46d1-b830-6fa223decc3b.png?v=1762481013"},{"product_id":"tp20oslsela-5-20-awg-5-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP20(OS)LSELA-5 20 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"\u003ch2\u003e\u003cb\u003eTP20(IS-OS)LSELA-5 20 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity for\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e TP20(IS-OS)LSELA-5 20 AWG 5 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V: 100 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThis marine tech cable is used as a signal cable on board of ships and in offshore marine rigs. The voltage rating of the cable is 300 volts. The overall temperature rating of this cable is 90°C. The cable is used on fixed and floating platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMarine tech cable, marine shipboard cable, marine cable, shipboard cable, LSE signal cable, TP(IS)LSETPO signal cable, aluminum armored cable, bronze armored cable, signal cable, halogen-free cable, 300V signal cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL (Underwriters Laboratories) as Marine Shipboard Cable according to international norms described in IEEE Std 1580-2001.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL E319439\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eABS Type Certificate No.10-HS592905-PDA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Std 1580-2001 as signal cable types LSETPO and LSEL\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed bare copper per ASTM B 3 and B 8. The stranding is Class C. Two cable conductors are twisted together to form a pair. Upon request, tinned copper conductor insulation or class B can be provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe insulation of the cable is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003etype LSE\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e cross-linked EPR. It is halogen-free and low-smoke, offering superior protection in case of a fire. All the cable components are held together with the help of non-hygroscopic fillers and polyester binder tape.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThere are two jacket options: TPO (thermoplastic polyolefin) and L (thermosetting cross-linked polyolefin). Both of these jackets are flame-retardant, halogen-free, and low-smoke. The subtle differences are merely identical to the overall differences between thermoplastic and thermoset jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage aluminum\/polyester tape and a copper drain wire that reflects the size of the conductor. The shielding is optional. Both component and overall shielding are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eArmor:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOptional bronze or aluminum armor is available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eAWG: 20\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 5\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eInsulation Thickness: 0.025 Inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 0.060 Inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCable Diameter (nominal): 0.563 Inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eArmored Cable Diameter (nom): 0.626 Inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCable Weight (approx.): 182.7 Lbs\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAluminum Arm. Cable Weight: 203 Lbs\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCable Type: TP20(IS)LSELA-5\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37651850592410,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/marine_ab1a3e0b-9e13-4625-b3aa-510970a6a57e.png?v=1762481014"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/ieee-1580-type-tposlsel-signal-cable-aluminum-bronze-armored-300v.oembed?page=3","provider":"NassauNationalCable","version":"1.0","type":"link"}